Background: Limited data are available on the dimensional stability and surface roughness of ThermoSens, which is a material used in denture processing. This study aimed to measure the vertical teeth changes and surface roughness of ThermoSens dentures prepared using three different investment materials. Materials and methods: For the dimensional changes test, 30 complete maxillary dentures were prepared using different investment methods: group I, dental stone; group II, silicone putty; and group III, a mixture of dental stone and plaster (ratio, 1:1; n = 10 for each group). Four screws were attached to the dentures: two were attached to the buccal surface of the canine and first molar, and the other two were attached in the flange areas of the canine and first molar in line with the previously mentioned screws. Measurements were made using a micrometer microscope in the wax stage before flasking and in the deflasking stage. The above investment techniques were also used to prepare samples for a surface roughness test (n = 10 per group). These samples were prepared according to the specifications of the American Dental Association. Data were examined using analysis of variance (ANOVA) and the least significant difference (LSD) test. Results: One-way ANOVA and LSD revealed that dimensional changes significantly differed among all groups, except that the vertical teeth changes on the left side did not differ between groups I and II for both the canine and molar regions. Surface roughness was significantly higher in group I than in group II, and in group III than in group II. Conclusion: The use of putty silicone for investing ThermoSens complete dentures reduced dimensional changes and resulted in dentures with a better fit. Surface roughness could be reduced by the addition of a putty silicone layer over the denture before the addition of the second investment layer during denture processing.
Experimental and numerical investigations of the centrifugal pump performance at non-cavitating and cavitating flow conditions were carried out in the present study. Experiments were performed by applying a vacuum to a closed-loop system to investigate the effects of the net positive suction head available (NPSHa), flow rate, water temperature and pump speed on the centrifugal pump performance. Accordingly, many of the important parameters concerning cavitation phenomenon were calculated. Also, the noise which is accompanied by cavitation was measured. Numerical analysis was implemented for two phase flow (the water and its vapor) using a 2-D simulation by ANSYS FLUENT software to investigate the internal flow of centrifugal pump under c
... Show MoreBackground: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the
... Show MoreBackground: The effect of garlic extracton fungal
growth and keratinolytic activity was studied in
Trichophytonmentagrophytes as one of the major
etiologic agents of human and animal dermatophytosis
in Baghdad and other parts of the World.
Objective: To investigated an alternative
antidermatophyte with minimum side effects which is
plant based and biodegradable natural product
Methods: Culture conditions for 30 isolates of T.
mentagrophytes isolated from human dermatophytosis
from both sexes with ages of 5-63 years in Central
Medical city for the period July 2009 to October 2009
were cultured on specific solid medium.
Results: The aqueous extract of garlic at various
concentrations inhibited the
Background: Maxillary first premolar with wide MOD cavity more susceptible to fracture. The aim of this study was to assess the influence of cavity design for cusp coverage on the fracture resistance of weakened maxillary first premolar restored with CAD/CAM hybrid ceramic versus nanohybide composite. Materials and Methods: Fifty six intact maxillary first premolars of approximately comparable sizes were divided into seven groups eight for each: Group A: Intact teeth (control group); Group B: teeth prepared for MOD inlay; Group C: teeth prepared for MOD onlay covering the lingual cusp; Group D: teeth prepared for MOD covering buccal and lingual cusps ,the previous three groups indirectly restored with nanohybrid composite (3M ESPE Z 250 X
... Show MoreInvestment in Human is one of the best and most important investments as it is renewed and developed resource over time in comparison with depleted material resources. Human resources is considered the part of the population that could be employed economically to contribute in increasing production energies as it is the support pillar of the society and have great energies that construct the society and raise of nations as well as he is distinguished with characteristics of ambitions to freedom.
Iraq is one of the countries that has large number of population in age of work and production and reduce in age dependent classes (children and old people).This dynamic in population led to step
... Show MoreThe aim of this paper is to construct cyclic subgroups of the projective general linear group over from the companion matrix, and then form caps of various degrees in . Geometric properties of these caps as secant distributions and index distributions are given and determined if they are complete. Also, partitioned of into disjoint lines is discussed.
Cadmium sulfide (CdS) nanocrystalline thin films have been prepared by chemical bath deposition (CBD) technique on commercial glass substrates at 70ºC temperature. Cadmium chloride (CdCl2) as a source of cadmium (Cd), thiourea (CS(NH2)2) as a source of sulfur and ammonia solution (NH4OH) were added to maintain the pH value of the solution at 10. The characterization of thin films was carried out through the structural and optical properties by X-ray diffraction (XRD) and UV-VIS spectroscopy. A UV-VIS optical spectroscopy study was carried out to determine the band gap of the nanocrystalline CdS thin film and it showed a blue shift with respect to the bulk value (from 3.9 - 2.4eV). In present w
... Show MoreThe Results of Theoretical Studies and Experiment of Advanced Economies , Have Been Proven That Investment Expenditure Is Not The Only Factor And The Main Source of Production Growth, But Efficient Using Of The Fixed Assets Is More Important In This Process, All That Depends On Groups of Factors Called The Non-Investment Economic Growth, That Are Un-bodied Technical Progress With Organizational Nature.
It's Distinguished Features That it has An Influence on The Production Growth Without Any Large Additional Investment Expenditure Or Any Additional Increment in Inputs And That Can Not Be Reached Without Activating The Factors of Non-Investment Economic Growth, Which is Still Affecting Negatively In T
... Show MoreThis work aims to investigate the tensile and compression strengths of heat- cured acrylic resin denture base material by adding styrene-butadiene (S- B) to polymethyl methacrylate (PMMA). The most well- known issue in prosthodontic practice is fracture of a denture base. All samples were a blend of (90%, 80%) PMMA and (10%, 20%) S- B powder melted in Oxolane (Tetra hydro furan). These samples were chopped down into specimens of dimensions 100x10x2.5mm to carry out the requirements of tensile tests. The compression strength test specimens were shaped into a cylinder with dimensions of 12.7mm in diameter and 20mm in length. The experimental results show a significant increase in both tensile and compression strengths when compared to cont
... Show More