Background: Coated archwires have been introduced to improve esthetics during orthodontic treatment. Theaim of the present study was to evaluate and compare the load–deflection characteristics and force levels of six brands of coated nickel titanium orthodontic archwires using palatal and gingival deflection. Materials and methods: Ten round wires (0.016 inch) and ten rectangular wires (0.019x0.025 inch) were obtained from each of six brands (G&H, Opal, Ortho Technology, Dany, Hubit and Astar Companies). The load-deflection properties of these archwires were evaluated by the modified bending test usinga readymade dental arch model in both palatal and gingival directions at 37°C temperature using a universal material testing machine. Forces generated at maximum loading of 2mm and at unloading of 1.5mm were measured. Results: All the wires showed hysteresis and significant differences in their load deflection curves, but these differences were more evident in round wires than in rectangular wires where G&H wires showed the widest loading- unloading deflection curves. The maximum loading force of round wires in gingival deflection were higher than by palatal deflection. The force decline during unloading (plateau gap) ranged between 18 to 34% for round wires and 17 to 37% for rectangular wires. Conclusion: Coated epoxy wires (G&H, Opal, Astar and Ortho Technology) produced lower forces compared to polymer (Dany) and Teflon (Hubit) coated round and rectangular archwire.
Background: Contact between implant material and bones must be strong and fast creation, to fulfill these properties appropriate surface modifications must apply on used implants. In this contribution; double surface modifications are applied on Ti-6Al-4V alloy to accelerate osseointegration. Materials and methods: Anodic process is utilized to create titania nanotubes (TNTs) on the screws made from Ti-6Al-4V alloy. These implants were coated with nano ZrO2 particles. Second modification was annealing anodized screws at 8000C, and implanted in tibiae of nine adult New Zealand white rabbits. Results: Physical and histological consequences of two surface modifications on Ti-6Al-4V alloy screws were studied. Scanning electron microscope (SEM)
... Show MoreThe world has witnessed in recent years a major development in the movement of investment, especially Foreign Direct Investment has got the developing countries, including Arab states share a small insignificant sometimes, despite the paucity of these flows, they have influenced, directly or indirectly in the labor force, and the provision of employment opportunities or Strengthening unemployment, and their impact in both cases depends on the availability of the determinants to attract foreign investment in host countries, and the extent of indulgence Governments of those countries with foreign investors through investment laws enacted by that may be imposed on foreign investors run a certain percentage of local
... Show MoreThe tourism services provided in the hotel organizations are a set of material and moral elements that represent tourist attractions that are offered to the guests in order to satisfy their needs and desires are accommodation, food, drink and other facilities to reach the satisfaction and satisfaction of guests.Where these tourist services need a mechanism to ensure their quality by working to identify and calculate the costs of these services properly and accurately with the attempt to referendum and reduce the waste and loss to reduce these costs while providing the finest types of tourism services by calculating the cost of production and the administration seeks to reduce Non-essential activities through hotel activities that add val
... Show MoreBackground: The therapeutic goal of orthodontic treatment is to establish ideal occlusion which includes both static and functional aspects. The objective of this study was to clarify functional occlusal treatment goals by analyzing functional occlusion in subjects with established normal occlusion and identify the differences between canine protected occlusion and group function occlusion. Materials and Methods: The sample consisted of 62 subjects with normal occlusion and with an age range of (18-25 years).Functional occlusal contacts during lateral excursion were identified on a fully adjustable articulator, and then the samples were classified according to: 1) Type of functional occlusion: A) Canine protected occlusion group (canine pr
... Show MoreBackground: Although the new treatment methods developed in recent years are aiming to minimize the need for cooperation of the patients; however, the latter still important factor the treatment. The aim of the study was to evaluate the cooperation level of Class III maloc-clusion patients with orthodontic treatment. Materials and methods: This study followed a cross-sectional style; the targeted population was patients with Class III malocclusion who were treated with three different types of orthopaedic appliances. Four questionnaires were delivered to the patient, patient’s parents, and orthodontists. Statistical analyses of the study were performed with SPSS 20.0 software. Descriptive analyses were presented using fre-quency, percenta
... Show MoreOrthodontic treatment has two major problems: being lengthy and costly procedure. The present study was designed to evaluate the clinical efficacy of locally injected vitamin D3 Keywords: Orthodontic, Calcitriol, Local injection, OTM (calcitriol) in accelerating orthodontic teeth movement (OTM) and reducing treatment time and cost in humans. The study was performed on 15 Iraqi adult orthodontic patients within the age range 17-28 years, they are randomly allocated into three groups, each of five patients and treated with either 15 pg, 25 pg, or 40 pg/0.2ml calcitriol diluted with 10% dimethylsulfoxide (DMSO). The maxillary arch of every patient was divided into control (right) and experimental (left) sides. In addition to force application,
... Show MoreBackground: The purpose of the current study was to evaluate the efficacy of a new orthodontic bonding system (Beauty Ortho Bond) involving the shear bond strength in dry and wet environments, and adhesion remnant index (ARI) scores evaluation in regard to other bonding systems (Heliosit and Resilience Orthodontic Adhesives). Materials and methods: Sixty defect free extracted premolars were randomly divided into six groups of 10 teeth each, mounted in acrylic resin, three groups for a dry environment and three for a wet one. Shear bond strength test was performed with a cross head speed of 0.5 mm/min, while surfaces of enamel and bracket-adhesive-enamel surfaces were examined with stereomicroscope For ARI scores evaluation. Data were analyz
... Show MorePhotovoltaic devices (PVs) were fabricated by spray-coating an ink of copper indium diselenide CuInSeR 2 R(CIS) nanocrystals as the light-absorbing layer. Without high-temperature post-deposition annealing, PVs were made on glass substrates with power conversion efficiencies of up to 1.5% and 0.9%, for Au and Mo coated respectively, under AM 1.5 illumination. UV–Vis spectrophotometer in the wavelength range 350–1500 nm. X-ray diffraction (XRD) and energy dispersive spectroscopy (EDS) analysis it is evident that CuInSeR 2 R have the chalcopyrite structure as the major phase and no secondary phase with a preferred orientation along (112) direction and The atomic ratio of Cu : In : Se in the nanocrystals is nearly 1 : 1 : 2.