Preferred Language
Articles
/
jbcd-725
Effect of different staining materials on color stability of sapphire brackets bonded with different types of light cure orthodontic adhesives (An in vitro study)
...Show More Authors

Background: The demand for better esthetic during orthodontic treatment has increased nowadays, so orthodontists starting using esthetic arch wires, brackets and ligatures.Tooth colored brackets were introduced in different types of materials. Sapphire ceramic brackets are one type of esthetic brackets and their color stability remains the main concern for the clinicians and patients at the same time. The present study design to evaluate the effect of three different staining materials (pepsi, black tea and cigarette smoke) on the stainability of sapphire ceramic brackets bonded with three types of light cure orthodontic adhesives which include: Resilience, Enlight and Transbond. Materials and Methods: The sample consisted of three hundred sixty sapphire brackets. The brackets were divided according to bonding materials into three groups each group consist of one hundred twenty brackets, then each subgroup farther subdivided into four groups according to the material they were immersed (distilled water, black tea, Pepsi and cigarette smoke) with thirty brackets each, then Each group with ten brackets farther subdivided according to time interval of immersion in each media into three groups one day, seven days and fourteen days at 37°C in the incubator.A UV-Visible spectrophotometer (Shimadzu, UV -1800) was used to perform a light absorption test. Results: ANOVA and LSD post Hoc tests were used to identify the significant effects of the staining materials at a significance level P ≤ 0.05.It was found that the immersion time gradually influenced the color stability of the adhesive materials with sapphire brackets with the highest activity observed at fourteen days interval. The brackets bonded with Resilience light cure adhesive are the most type affected by staining materials, then followed by the brackets bonded with Transbond and finally the brackets bonded with Enlight light cure adhesive. For the staining materials it was found that the cigarette smoke is the most powerful staining material, followed by tea and finally pepsi. Conclusions: From the above result we can conclude that the type of adhesive must take in consideration when the esthetic brackets have been used.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Efficacy of Combination of Meropenem with Gentamicin, and Amikacin against Resistant E. coli Isolated from Patients with UTIs: in vitro Study
...Show More Authors

         Seventy five E. coli isolates were collected from urine of patients with urinary tract infections in AL-Kadhimia and AL-Yarmook teaching hospitals in Baghdad for a period between 22/11/2009 to 15/3/2010,  from these samples twenty five isolates were selected according to their pattern of the highest resistance as these showing multi-drug resistances and tested to specify their minimum inhibitory concentration for (meropenem, gentamicin and amikacin), meropenem was found having the lowest MIC comparing with others. This study also includes in vitro effects of various combinations of three types of antimicrobials (meropenem, gentamicin and amikacin) against twenty five E. c

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Nov 16 2025
Journal Name
Sciences Journal Of Physical Education
Use different means rehabilitative according some bio-kinematics variables and their impact on increasing range of motion for people with shoulder joint
...Show More Authors

View Publication
Publication Date
Thu Aug 29 2024
Journal Name
European Journal Of Orthodontics
Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction
...Show More Authors
Abstract<sec> <title>Background

Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.

Objective

To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).

Trial design

A single-centre, two-arm parallel groups

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2019
Journal Name
Prensa Medica Argentina
The effect of niclosamide in acetic-acid induce colitis: An experimental study
...Show More Authors

Scopus (28)
Scopus
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
The effect of expectations and perceptions in service quality (An Empirical Study)
...Show More Authors

Abstract

  The study aims to find out the impact of expectations and perceptions in determining the position of the customer service quality received by him. Represent the expectations and perceptions customer’s key of service quality determinants. The customer's requirements and needs main pivot, who must be built all events and activities and efforts of service organizations, including the hotel and organizations that operate in an environment known as highly competitive , intensification and  complexity of the conditions set by the customer and increasing day after day. The study sample of three Luxury hotels in Kurdistan region of Iraq a model. The use of service quality m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of Operating Conditions of Urea Dewaxing on the Pour Point of Light Lubricating Oil
...Show More Authors

An investigation was conducted for dewaxing of lubricating oil fraction by urea to reduce the pour point.In this study mixture of 45 % methyl ethyl ketone (MEK) and 55 % toluene was used as a solvent. The studied variables are mixing time (10-70 min), solvent to oil volume ratio (0.5:1- 2:1), urea to wax weight ratio (2- 6) and constant mixing speed 1500 rpm. By analysis of the experimental results, the best operating conditions achieved are mixing time 40 min, solvent/oil 2:1 volume ratio, and urea/wax 4:1 weight ratio. At these conditions the pour point of the lubricating oil decreases from 24 ° C to -13 °C.

View Publication Preview PDF
Publication Date
Sun Nov 16 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Effects of Nano-Hydroxyapatite and Casein Phosphopeptide-Amorphous Calcium Phosphate in Preventing Loss of Minerals from Teeth after Exposure to an Acidic Beverage (An In vitro Study)
...Show More Authors

Background: To evaluate the effect of antierosive agents (10% Nano-Hydroxyapatite (NHA), 10% Casein Phophopeptide-Amorphous Calcium Phosphate (CPP-ACP), and combination of 10% NHA and 10% CPP-ACP) on loss of minerals from enamel surface of permanent teeth treated with antierosive agents when exposed to an acidic beverage and investigate the morphological changes of treated enamel surface after demineralization with cola based beverage under Scanning Electron Microscope (SEM). Materials and Methods: Sixty maxillary first premolars were randomly divided into four groups, 15 teeth for each group. Group I treated with 10% NHA, Group II treated with 10% CPP-ACP, Group III treated with 10% NHA and 10% CPP-ACP, and Group IV did not treat with any

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro The Effect of Canals Instrumented With Three Rotary Ni-Ti Systems on The Dislocation Resistance of Guttafusion® Versus Single Cone Obturation Technique
...Show More Authors

Background: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randoml

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Archives Of Razi Institute
Antimicrobial Effect of Moringa Oleifera L. and Red Pomegranate against Clinically Isolated Porphyromonas gingivalis: in vitro Study
...Show More Authors

Moringa oleifera L. and red pomegranate extracts have been reported to inhibit gram-positive facultative anaerobe growth and inhibit the formation of biofilm on tooth surfaces. The current study aimed to assess the antibacterial effect of M. oleifera L. and red pomegranate extracts and their combinations against Porphyromonas gingivalis. The antimicrobial sensitivity, minimum inhibition concentrations (MIC), and minimum bactericidal concentrations after treatment with the aqueous extracts of M. oleifera L. and red pomegranate as well as their combination against clinically isolated P. gingivalis were determined using agar well diffusion and two-fold serial dilution. The anti-biofilm activity of the extracts and their combination was evaluat

... Show More
View Publication Preview PDF
Scopus (5)
Scopus
Publication Date
Sun Nov 16 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of poly propylene fibers incorporation and their oxygen plasma treatment on tensile strength, wettability and wear resistance of heat cure denture base acrylic resin
...Show More Authors

Background: Recently, Poly propylene fibers with and without plasma treatment have been used to reinforce heat cure denture base acrylic but, so far some of properties like tensile strength , wettability and wear resistance not evaluated yet, the aim of the study is to clarify the influence of incorporation of treated and untreated fibers on these properties. Materials and methods: Twenty one specimens were fabricated for every tested property(tensile strength, wear resistance and wettability) that classified into three groups(control, untreated poly propylene fibers reinforced specimens and Oxygen plasma treated group)and for each test sevens amples were used(n=7). Tensile strength was tested using Instron universal testing machine, wear

... Show More
View Publication Preview PDF