Preferred Language
Articles
/
jbcd-708
Estimation of the linear dimensional changes of autoclave cured acrylic resin with multiple palatal depths and investment materials
...Show More Authors

Background: Dimensional changes of acrylic denture bases after polymerization results in need for further adjustments or even ends with technical failure of the finished dentures. The purpose of this study was to estimate the linear dimensional changes for different palatal depths when using multiple investment materials and polymerization techniques. Materials and methods: Ninety upper complete denture bases were constructed for this study. They were divided into two main groups according to the polymerization methods: conventional water bath and experimental autoclave (short and long cycles). Each main group was further subdivided into three subgroups according to the palatal depth (shallow, medium and deep). Furthermore, for each palatal depth; complete denture bases were invested either with dental stone or laboratory silicone. For each upper complete denture, measurements of linear dimensional changes were done by fixation of metallic screws on the tissue surface of the denture base. The distances were measured by using travelling microscope with an accuracy of 0.001 %. The data were statistically analyzed using three way analysis of variance (ANOVA) for three variables, which were (palatal depth, investments and polymerization techniques), LSD test and student T test for comparisons between groups. Results: There were significant improvements in the dimensional accuracy of denture bases cured with autoclave compared with water bath. Also, silicone investments were a successful alternative to stone, study data shows that short autoclave processing with silicone reduces the magnitude of the linear dimensional changes. On the other hand, long autoclave processing and stone investments were better than silicone in reducing dimensional changes. Conclusion: The findings of this study indicates that the use of autoclave processing in acrylic curing is a promising alternative to the conventional water bath and leads to better dimensional stability for the finished dentures in all oral configurations and palatal depths. Also, Silicone is more preferable than stone, although it's not as strong investing materials when compared with stone.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
International Journal Of Medical Research & Health Sciences
Clinical and Radiographical Assessment of Alveolar Bone Loss Associated with Overhang Amalgam Filling
...Show More Authors

Publication Date
Tue Jul 10 2018
Journal Name
Journal Of Global Pharma Technology
Synthesis, Spectral Studies and Biological Activity of Azo dye Complexes with Some MetalIons
...Show More Authors

2-(2-amino-5-nitro-phenylazo),-phenol was ready by grouping the diazonium salt of 2-aminophenol with 4-nitroaniline.Thegeometry of azo ligand(HL)was resolved on the origin of (C.H.N) analysis,1H and 13CNMR spectra, infrared spectra and UV–vis electronic absorption spectra. Dealing with the azo ligand produced with Rh+3 and La+3ataqueous ethanol for a 1:3 metal: ligand rate, and in perfect ph. The formation for compounds have been described by utilizing flame atomic, absorption,(C.H.N),Analyses, conductivity, infrared spectra and UV–vis spectral procedures. Nature in the produced compounds, have been studied, obey the ratio of mole and continuous, variance, manners, Beer's law, yielded up a concentration, rate (1×10-4- 3×10-4M),. High

... Show More
Preview PDF
Publication Date
Thu Jan 29 2026
Journal Name
Iraqi Journal Of Agricultural Sciences
EFFECT OF TILLAGE WITH CHISEL PLOW ON SOIL MEAN WEIGHT DIAMETER AND POROSITY
...Show More Authors

View Publication
Publication Date
Wed Dec 27 2017
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study of Capillary Tubes Behavior With R-12 and R-134a
...Show More Authors

 

Experimental work has been performed on three capillary tubes of different lengths and diameters using R-12 and R-134a. The test also studies the effect of discharge and speed of evaporator fan. The results clearly showed that refrigerant type and discharge significantly influence the temperature drop across the capillary tube. While the speed of evaporator fan has small effect. Experimental results showed that the temperature gradient for the two refrigerants are the same, but after approximatly one meter the temperature gradient of R-134a  is steeper than R-12.

 

View Publication Preview PDF
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
Evaluation of ELectrolytes in Adult Patients with Acute Leukemia before and after Chemotherapy
...Show More Authors

Abstract:Leukemia is a cancer of early blood forming cells. Most of them are cancers of white blood cells , however some leukemias start in other blood cell types.Electrolytes have modulatory effects on several biological mechanisms in the body namely as stabilizers,element of structures, essential element for hormonal function and also co-factors for a number of enzymes.In this study serum electrolytes levels were measured in patients with acute leukemia (AL) disorders before and after chemotherapy(anthracycline, doxorubicin, cytarabine ,prednisone, vincristine and doxorubicin) during one month and compared with that of control group. Blood samples were obtained from (43) patients (28 males and 15 females) aged (15-55)years;juset before an

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Clinical and Doppler Study of Restrictive Filling Pattern in Patients with Dilated Cardiomyopathy
...Show More Authors

Background: Dilated cardiomyopathy (DCM) is a well-recognized cause of cardiovascular morbidity and mortality.Objectives: To evaluate the prognostic implications of the restrictive left ventricular filling pattern (RFP) in dilated cardiomyopathy.Methods: Patients with DCM admitted to Ibn AL-Bitar Hospital for Cardiac Surgery, Baghdad-Iraq, from May 2006 to August 2008, underwent a full clinical evaluation and Doppler echocardiography study. Patients were classified into three groups: Group I had persistent restrictive filling pattern; Group II had reversible restrictive filling pattern; and Group III had nonrestrictive filling pattern. Results: The current study was conducted on a total number of 80 patients with DCM, fifty (62.5 %) were

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 03 2022
Journal Name
Basra Journal Of Science
Morphological and Electrical properties of Polyvinylpyrrolidone/Multi-walled Carbon Nanotubes Nanocomposite with Graphene
...Show More Authors

The solution casting method was used to prepare a polyvinylpyrrolidone (PVP)/Multi-walled carbon nanotubes (MWCNTs) nanocomposite with Graphene (Gr). Field Effect Scanning Electron Microscope (FESEM) and Fourier Transformer Infrared (FTIR) were used to characterize the surface morphology and optical properties of samples. FESEM images revealed a uniform distribution of graphene within the PVP-MWCNT nanocomposite. The FTIR spectra confirmed the nanocomposite information is successful with apperaring the presence of primary distinct peaks belonging to vibration groups that describe the prepared samples.. Furthermore, found that the DC electrical conductivity of the prepared nanocomposites increases with increasing MWCNT concentratio

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (3)
Scopus Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Basra Journal Of Science
Preparation and Characterization of Polyvinylpyrrolidone/Multi-walled Carbon Nanotubes Nanocomposite hybrid with Graphene
...Show More Authors

In this work, polyvinylpyrrolidone (PVP), Multi-walled carbon nanotubes (MWCNTs) nanocomposite was prepared and hybrid with Graphene (Gr) by casting method. The morphological and optical properties were investigated. Fourier Transformer-Infrared (FT-IR) indicates the presence of primary distinctive peaks belonging to vibration groups that describe the prepared samples. Scanning Electron Microscopy (SEM) images showed a uniform dispersion of graphene within the PVP-MWCNT nanocomposite. The results of the optical study show decrease in the energy gap with increasing MWCNT and graphene concentration. The absorption coefficient spectra indicate the presence of two absorption peaks at 282 and 287 nm attributed to the π-π* electronic tr

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Crossref
Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Agricultural Sciences
RESPONSE SEEDS PRODUCTION OF BROAD BEAN TO FOLIAR SPRAY WITH MAGNESIUM AND BORON
...Show More Authors

Scopus (12)
Crossref (5)
Scopus Crossref
Publication Date
Fri Jul 28 2017
Journal Name
Iraqi Journal Of Science
Morphological and Optical Properties of CdS Quantum Dots Synthesized with different pH values
...Show More Authors

View Publication
Crossref