Background: Irrigation of the canal system permits removal of residual tissue in the canal anatomy that cannot be reached by instrumentation of the main canals so the aim of this study was to compare and evaluate the efficiency of conventional irrigation system, endoactivator sonic irrigation system,P5 Newtron Satelec passive ultrasonic irrigation and Endovac irrigation system in removing of dentin debris at three levels of root canals and to compare the percentage of dentin debris among the three levels for each irrigation system. Materials and methods: Forty extracted premolars with approximately straight single root canals were randomly distributed into 4 tested groups of 10 teeth each. All canals were prepared with Protaper Universal hand files to size #F4, and irrigated with 2.5% NaOCI 1 ml between files and 5ml for 60 seconds as a final irrigant by different irrigation devices; group one, by using conventional system; group two, by using Endoactivator sonic irrigation system, group three, by using Satelec Passive Ultrasonic irrigation and group four by using the Endovac system. After the final irrigation, the roots were split longitudinally and photographed with a digital microscope. The roots were magnified to 100X; a percentage of debris was calculated for the apical 0-3, middle 3-6 and coronal 6-9 mm. The debris score was calculated as a percentage of the total area of the canal that contained debris as determined by pixels in Adobe PhotoshopCS5. Data were analyzed statistically by ANOVA and LSD at 5% significant level. Results: when comparing the debris remaining, the Endovac, Endoactivator and Satelec groups showed significantly less debris than the conventional group at all three levels (p < 0.01). The Endovac group showed significantly less debris than the Endoactivator group at middle and coronal levels while no significant difference found between the Endovac system and Endoactivator system at apical level. The apical 0-3 mm showed significantly more debris than both the middle and coronal level for all groups. Conclusion: The EndoVac system showed a higher cleaning capacity of the canal at all levels, followed by the protocols that used Endoactivator sonic irrigation system. The conventional irrigation system with maxi-i-probe needles showed inferior results. The apical three millimeters showed a greater amount of debris than the 3-9 millimetres from the working length, regardless of the irrigation device used.
Numerical simulations have been investigated to study the external free convective heat transfer from a vertically rectangular interrupted fin arrays. The continuity, Naver-Stockes and energy equations have been solved for steady-state, incompressible, two dimensional, laminar with Boussiuesq approximation by Fluent 15 software. The performance of interrupted fins was evaluated to gain the optimum ratio of interrupted length to fin length (
Background: Apexification is a method to induce a calcified barrier in a root with an open apex or the continued apical development of an incomplete root in teeth with necrotic pulp. MTA apexification has several advantages such as it neither gets resorbed, nor weakens the root canal dentin, and also sets in the wet environment. The aim of this study is to evaluate the effectiveness of the use of MTA in apexification and periapical healing of teeth with incomplete root formation and periapical infection. Materials and method: Apexification was carried out on fourteen permanent immature teeth of eleven children aged 7-12 years attended the teaching hospital of College of Dentistry, Baghdad University using mineral trioxide aggregate followed
... Show MoreThis study involved preparation of Graphene oxide (GO) and reduced graphene oxide (RGO) using Hummer method and chemical method respectively. These carbon nanomaterials were used as starting material to make novel functionalize with thiocarbohydrazide (TCH) which was prepared by reacting CS2 with hydrazine to form GO or RGO- 4-amino,5-substituted 1H,1,2,4 Triazole 5(4H) thion (ASTT) ,(GOT) and( RGOT) respectively via cyclocondensation reaction. Also MnO2 nanorod was prepared to form hybridized with GOT and RGOT. A commercial multiwall carbon nanotube (MWCNT) and functionalization with carboxylic groups' (f-MWCNT) and its nanocomposite with GOT were also prepared. All carbon nanomaterials were characterized with different techniques such as
... Show MoreFive different bacterial isolates [ Vibrio cholera (Ogawa) , Vibrio cholera (Inaba) , Salmonella typhi , Salmonella paratyphi and ? Salmonella typhimurium ] were obtained from the Central Health Laboratory . Both sensitivity tests (MIC , MBC and wells method ) against these bacteria were performed by using the aqueous of leaves extract of Marjoram plant. The results cleared that the values of MIC for Vibrio cholera serotypes Ogawa and Inaba were 100 mg/ml , while the value of MBC was 200 mg/ml. The value of the Inhibition zone at 100 mg /ml concentration for both Ogawa and Inaba were 13 mm and 9 mm respectively. Our results showed that the three types of Salmonella didn’t show any inhibition zone at 200 mg/ml .
WKAJ Khalifa E. Sharqui1,*, Adil A. Noaimi2, Ali R. Auda3, American Journal of Dermatology and Venereology, 2014 - Cited by 1
Physically based modeling approach has been widely developed in recent years for the simulation of dam failure process due to the lack of field data. This paper provides and describes a physically-based model depending on dimensional analysis and hydraulic simulation methods for estimating the maximum water level and the wave propagation time from breaching of field test dams. The field physical model has been constructed in Dabbah city to represent the collapse of the Roseires dam in Sudan. Five cases of a dam failure were studied to simulate water flood conditions by changing initial water height in the reservoir (0.8, 1.0, 1.2, 1.4 and 1.5 m respectively).The physical model working under five cases, case 5 had the greatest influence of t
... Show MoreThe research on coordination polymers chemistry based on organic-metal framework with bridging ligands has accelerated during the past two decades. It is an interested hot topic in the synthetic inorganic chemistry, which allowed the fabrication of a variety of interested materials. These materials have shown a range of applications including light harvesting and magnetic properties. The thesis is divided in three chapters. The first chapter gives a general introduction on the development of self-assembled polymeric species based on transition metal. It is also covered a summary of the literature review on the current state of the art on self-assembled coordination ploymers. Furthermore, it includes a description on various relevant topics
... Show MoreTwo of the main advantages of segmental construction are economics, as well as the rapid construction technique. One of the forms of segmental construction, for structural elements, is the segmental beams that built-in short sections, which referred to segments. This research aims to exhibit a new technique for the fabrication of short-span segmental beams from wedge-shaped concrete segments and carbon fiber reinforced polymers (CFRP) in laminate form. The experimental campaign included eight short-span segmental beams. In this study, two selected parameters were considered. These parameters are; the number of layers of CFRP laminates and the adhesive material that used to bond segments to each other, forming short-span segmental be
... Show MoreCO2 Laser (10600nm) is the recent method in the management of challenging skin scar resulting from trauma, burn and surgical wound. The aim of this study was to evaluate the efficacy & safety of fractional CO2 laser (10600nm) in treatment of skin scar. Materials and Methods:Twenty patients with different types of scars treated with fractional CO2 (10600nm) laser, (10 patients) were given additional intralesional Triamcinolone. Results: All of the twenty patients included in this study showed some sort of improvements in scar texture, height and pliability and all of the ten patients who received intralesional Triamcinolone after laser show complete satisfaction. Conclusion:Fractional CO2 (10600nm) laser can be used as alternative, ef
... Show More