Background: Simultaneous and staged guided bone regeneration (GBR) is one of the several surgical techniques that have been developed in the past two decades to regenerate bone and thus to allow implant placement in compromised sites (fenestration and dehiscence). It is a surgical procedure that consists of the placement of a cell-occlusive physical barrier between the connective tissue and the alveolar bone defect. The treatment concept advocates that regeneration of osseous defects is predictably attainable via the application of occlusive membranes, which mechanically exclude non-osteogenic cell populations from the surrounding soft tissues, thereby allowing osteogenic cell populations originating from the parent bone to inhabit the osseous wound. Augmentation utilizing guided bone regeneration (GBR) has become a major treatment option to provide optimal bone to support Osseointegrated dental implants. One of the objectives of GBR is the formation of new bone at sites deficient in bone volume. Another objective is to treat fenestrations and dehiscence at implant surfaces as well as defects associated with simultaneous implant placement. GBR has allowed for placement of restorations at a more ideal location in the oral cavity, thus improving esthetics and functions. This study aimed to improve the alveolar ridge width by using of synthetic bone substitute covered by resorbable collagen membrane in simultaneous dental implants placement and to compare the ridge width at three levels (crestal, middle and apical) clinically (osteometer) and radiographically (CT) pre operatively and postoperatively. Materials and methods: This prospective study was conducted in teaching dental hospital in College of Dentistry of Baghdad University on (15) patients with (21) dental implant with insufficient bony support for simultaneous dental implants , this study extended from March 2013 to the end of December 2013. All patients were treated at the time of implantation by using a synthetic bone substitute covered by resorbable collagen membrane .All patients examined clinically by osteometer and radio graphics (CT) to assess ridge width and height and bone density. Results: Clinically and radiographically evaluation showed increasing of ridge width after 6 months of healing period at three levels: apical, middle and crestal, statistically, there were no significant differences between ridge width gain measured clinically and radio graphically and gender and age groups. In this study the success rate (95.24) % in (20) dental implant and only (1) dental implant was failed (4.76) % at age 47 years old. Conclusion: There was significant increase in ridge volume that augmented at the time of implantation to become sufficient width for support implant esthetically and functionally. This study revealed that there was no effect in gender and age on bone augmentation with synthetic bone substitute. Keywords: GBR, Simultaneous dental implant, osteometer, CT, ridge width and height and bone density.
The effects of nutrients and physical conditions on phytase production were investigated with a recently isolated strain of Aspergillus tubingensis SKA under solid state fermentation on wheat bran. The nutrient factors investigated included carbon source, nitrogen source, phosphate source and concentration, metal ions (salts) and the physical parameters investigated included inoculum size, pH, temperature and fermentation duration. Our investigations revealed that optimal productivity of phytase was achieved using wheat bran supplemented with: 1.5% glucose. 0.5% (NH4)2SO4, 0.1% sodium phytate. Additionally, optimal physical conditions were 1 × 105 spore/g substrate, initial pH of 5.0, temperature of fermentation 30˚C and fermentation dura
... Show MoreThe largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase
... Show MoreThis paper compare the accurecy of HF propagation prediction programs for HF circuits links between Iraq and different points world wide during August 2018 when solar cycle 24 (start 2009 end 2020) is at minimun activity and also find out the best communication mode used. The prediction programs like Voice of America Coverage Analysis Program (VOACAP) and ITU Recommendation RS 533 (REC533 ) had been used to generat HF circuit link parameters like Maximum Usable Frequency ( MUF) and Frequency of Transsmision (FOT) .Depending on the predicted parameters (data) , real radio contacts had been done using a radio transceiver from Icom model IC 7100 with 100W RF
... Show MoreThe paper is devoted to solve nth order linear delay integro-differential equations of convolution type (DIDE's-CT) using collocation method with the aid of B-spline functions. A new algorithm with the aid of Matlab language is derived to treat numerically three types (retarded, neutral and mixed) of nth order linear DIDE's-CT using B-spline functions and Weddle rule for calculating the required integrals for these equations. Comparison between approximated and exact results has been given in test examples with suitable graphing for every example for solving three types of linear DIDE's-CT of different orders for conciliated the accuracy of the results of the proposed method.