Preferred Language
Articles
/
jbcd-643
Analysis of inflammatory cells in osseointegration of CpTi implant radiated by low level laser therapy
...Show More Authors

Background: Dental implants provide a unique treatment modality for the replacement of a lost dentition .This is accomplished by the insertion of relatively an inert material (a biomaterial) into the soft and hard tissue of the jaws, there by providing support and retention for dental prostheses. Low level laser therapy (LLLT) is an effective tool used to prompt bone repair and remodeling, this has referred to the biostimulation effect of LLLT. The Aim of this study was to evaluate the effects of inflammatory cells on osseointegration of CpTi implant irradiated by low level laser. Materials and Methods: thirty two adult New Zealand white rabbits, received titanium implants were inserted in the tibia. The right side is considered as experimental groups and the left side considered as control groups. Low power diode laser (GaAlAs ) with wave length (904nm) and (5mW)power applicated with the right implants . The sample divided into four groups, eight rabbits were sacrificed at four interval 4days, 1 weeks, 2weeks, and 6weeks respectively. Histological and inflammatory analyses were done for each interval. Results: Histological examination showed acceleration of bone formation and more rapid healing process in the screw implant with laser irradiation than in the control implant .inflammatory analysis showed dramatic decrease with the presence of laser irradiation especially with advancing time. Conclusion: This study illustrated that the inflammatory cells were reduced in osseointegration of dental implant treated with LLLT. Key words: Dental Implants, low level laser therapy, inflammatory cell.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 25 2026
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Determination of Methionine Via Chemiluminescence-Continuous Flow Injection Analysis
...Show More Authors

The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto

... Show More
View Publication
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
FINITE ELEMENT ANALYSIS OF HUMAN AND ARTIFICIAL ARTICULAR CARTILAGE
...Show More Authors

Joint diseases, such as osteoarthritis, induce pain and loss of mobility to millions of people around the world. Current clinical methods for the diagnosis of osteoarthritis include X-ray, magnetic resonance imaging, and arthroscopy. These methods may be insensitive to the earliest signs of osteoarthritis. This study investigates a new procedure that was developed and validated numerically for use in the evaluation of cartilage quality. This finite element model of the human articular cartilage could be helpful in providing insight into mechanisms of injury, effects of treatment, and the role of mechanical factors in degenerative
conditions, this three-dimensional finite element model is a useful tool for understanding of the stress d

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 28 2024
Journal Name
Mathematical Modelling Of Engineering Problems
Structural and Stress Analysis of NACA0012 Wing Using SolidWorks
...Show More Authors

View Publication
Scopus (3)
Scopus Crossref
Publication Date
Thu Aug 31 2017
Journal Name
Journal Of Engineering
Energy Analysis of Solar Collector With perforated Absorber Plate
...Show More Authors

The thermal performance of three solar collectors with 3, 6 mm and without perforation absorber plate was assessed experimentally. The experimental tests were implemented in Baghdad during the January and February 2017. Five values of airflow rates range between 0.01 – 0.1 m3/s were used through the test with a constant airflow rate during the test day. The variation of the following parameters air temperature difference, useful energy, absorber plate temperature, and collector efficiency was recorded every 15 minutes. The experimental data reports that the increases  the number of absorber plate perforations with a small diameter is more efficient rather than increasing the hole diameter of the absorber plate with decr

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Finite Element Analysis of Raft Foundation under Coupled Moment
...Show More Authors

Due to wind wave actions, ships impacts, high-speed vehicles and others resources of loading, structures such as high buildings rise bridge and electric transmission towers undergo significant coupled moment loads. In this study, the effect of increasing the value of coupled moment and increasing the rigidity of raft footing on the horizontal deflection by using 3-D finite element using ABAQUS program. The results showed that the increasing the coupled moment value leads to an increase in lateral deflection and increase in the rotational angle (α◦). The rotational angle increases from (0.014, 0.15 to 0.19) at coupled moment (120 kN.m), (0.29, 0.31 and 0.49) at coupled moment (240 kN.m) and (0.57, 0.63 and 1.03) at cou

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jul 01 2011
Journal Name
Energy
Experimental and numerical analysis of electrical metal foam heater
...Show More Authors

A novel concept of air heater using a heating element made from Aluminum metal porous disc surrounded by a DC resistive electrical heater inserted in the mid-plane of a copper tube of (52.8 mm) diameter and (480 mm) length is presented herein. Study of the developed heater is conducted; using different porous disc thicknesses of (20, 40, 60 mm), heater wall temperatures (106 °C and 119 °C), and flow rates rare varied from (100–300 L/min). Al-metal foam disc has been made using the metal powder technology. Different resistive electrical heaters according to the type of porous disc used have been manufactured. A 2-D computational model is developed, using continuity, momentum, and energy equations for turbulent forced flow in plain tube,

... Show More
View Publication
Scopus (13)
Crossref (10)
Scopus Crossref
Publication Date
Mon Nov 27 2023
Journal Name
Korean Journal Of Orthodontics
Effectiveness of laser-engineered copper-nickel titanium versus superelastic nickel-titanium aligning archwires: A randomized clinical trial
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Oct 17 2018
Journal Name
Iraqi Journal Of Laser
Thermal Effects of 940 nm Diode Laser on Dental Socket Blood after Teeth Extraction for Diabetic Patients
...Show More Authors

Abstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females wi

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Sensing and differentiation between normal flora and pathogenic of E.coli Bacteria using 410 nm diode laser
...Show More Authors

Abstract: Background: Optical biosensors offer excellent properties and methods for detecting bacteria when compared to traditional analytical techniques.  It allows direct detection of many biological and chemical materials.  Bacteria are found in the human body naturally non-pathogenic and pathologically, as they are found in other living organisms.  One of these bacteria is Escherichia coli (E. coli) which are found in the human body in its natural and pathogenic form. E.coli bacteria cause many diseases, including Stomach, intestines, urinary system infections, and others. The aim of this study: is sensing and differentiation between normal flora and pathogenic E.coli. Material and method:

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 10 2024
Journal Name
Journal Of Optics
Pulsed laser deposition of Pd/WO3 nanoparticles on Si nanostructure for highly sensitive room-temperature gas sensors
...Show More Authors

View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref