Preferred Language
Articles
/
jbcd-631
Histological and histomorphometric analysis of strontium chloride coated commercially pure titanium implant compared with hydroxyapatite coating
...Show More Authors

Background: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium screws. The tibia of 4 white New Zealand rabbits was chosen as implantation sites. Each tibia of rabbit received two screws, one strontium chloride coated and one hydroxyapatite coated and a total 30 histological sections were obtained for each coating material in each period of time. Histomorphometric analysis was performed to measure new bone formed ratio between implant and original bone, after 2 and 6 weeks healing periods. Results: There was increased in new bone formation ratio for the strontium chloride coated implants than hydroxyapatite coated implants and over the two periods of time. There was an increase in the new bone formation ratio at bone-implant interface with time. Conclusion: Coating commercially pure titanium implant with strontium chloride was more efficient in increasing osseointegration at bone implant interface than hydroxyapatite , which was demonstrated by higher new bone formation and maturation at the two periods of time 2 weeks and 6 weeks after implantation. Keywords: Histomorphometric, commercially pure titanium, strontium chloride, hydroxyapatite.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 15 2022
Journal Name
Nasaq Journal
Componential Analysis of Hatred Synonymy in the Lexicons of English and Standard Arabic
...Show More Authors

ABSTRACT This paper has a three-pronged objective: offering a unitary set of semantic distinctive features to the analysis of nominal “hatred synonyms” in the lexicon of both English and Standard Arabic (SA), applying it procedurally to test its scope of functionality crosslinguistically, and singling out the closest noun synonymous equivalents among the membership of the two sets in this particular lexical semantic field in both languages. The componential analysis and the matching procedures carried have been functional in identifying ten totally matching equivalents (i.e. at 55.6%), and eight partially matching ones (i.e. at %44.4%). This result shows that while total matching equivalences do exist in the translation of certain Eng

... Show More
View Publication
Publication Date
Tue Jun 01 2021
Journal Name
Journal Of The College Of Languages (jcl)
A Multimodal Analysis of Hyperbolic Devices in Advertisements of Health and Beauty Products
...Show More Authors

         This paper examines the use of one of the most common linguistic devices which is hyperbole. It shows how hyperbolic devices are used as an aspect of exaggeration or overstatement for an extra effect in which the speaker can use hyperbole to add something extra to a situation in order to exaggerate his idea or speech. It is, like other figures of speech, used to express a negative or positive attitude of a specific unit of language. Thus, this paper is set against a background of using hyperbole concerning two main fields (advertisements and propaganda). So, the use of hyperbole will be implied by analyzing them concerning their meaning) literal and non-literal).  Methodology of this

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Analysis of Initiation and Growth of Plasma Channels Within Non-Mixed Dielectric Liquids
...Show More Authors

Pre-breakdown phenomenon was investigated within the two, non-mixed dielectric liquids; transformation oil and cresol. Finite element technique was used to follow the initiation and growth of plasma channels (streamer discharge) within pin-plane configuration. That was done for different spacing between the pin-electrode and the liquid-liquid interface. Streamer growth model assumed that, the streamer initiation occurs at the region of the highest value of electric field. Our study shows that the streamer initiates at the tip of the pin and growths toward the other electrode. The study shows, too, that the streamer path controlled by the difference of permittivity of the two liquids and spacing distance of the liquid-liquid interface fro

... Show More
View Publication Preview PDF
Publication Date
Tue Jul 01 2025
Journal Name
Mastering The Minds Of Machines
Future Computational Power of AI Hardware: A Comparative Analysis of GPUs and TPUs
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
International Journal Of Pharmaceutical Research
New method for the evaluation of propranolol with phosphotungstic acidvialong distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis
...Show More Authors

A new, simple and sensitive method was used forevaluation of propranolol withphosphotungstic acidto prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between propranolol and phosphotungstic acid in an aqueous medium to obtain a yellow precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.007-13 mmol/L for cell A and 5-15 mmol/L for cell B, and LOD 207.4792 ng/160 µL and 1.2449 µg/160 µL respectively to cell A and cell B with correlation coefficient (r) 0.9988 for cell A, 0.9996 for cell B, RSD% was lower than 1%, (n=8) for the

... Show More
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Thu Aug 31 2017
Journal Name
Journal Of Engineering
Finite Element Analysis of UHPC Corbels
...Show More Authors

   Finite element method is the most widely numerical technique used in engineering field. Through the study of behavior of concrete material properties, various concrete constitutive laws  and failure criteria have been developed to model the behavior of concrete. A feature of the Finite Element program (ATENA) is used in this study to model the behavior of UHPC corbel under concentrated load only. The Finite Element (FE) model is followed by verification against experimental results. Some variable effects on the shear capacity of the UHPC corbels are also demonstrated in a parametric study. A proposed design equation of shear strength of UHPC corbel was presented and checked with numerical results.
 

View Publication Preview PDF
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Analysis of Double Skin Composite Slabs
...Show More Authors

This paper deals with finite element modeling of the ultimate load behavior of double skin composite (DSC) slabs. In a DSC slab, shear connectors in the form of nut bolt technique studs are used to transfer shear between the outer skin made of steel plates and the concrete core. The current study is based on finite element analysis using ANSYS Version 11 APDL release computer program. Experimental programmes were carried out by the others, two simply supported DSC beams were tested until failure under a concentrated load applied at the center. These test specimens were analyzed by the finite element method and the analyses have shown that these slabs displayed a high degree of flexural characteristics, ultimate strength,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Engineering
ANALYSIS OF GEOTEXTILE EMBANKMENT BY ANSYS
...Show More Authors

The major objectives of this research are to analyze the behavior of road embankments
reinforced with geotextiles constructed on soft soil and describe the finite element analysis by using
ANSYS program ver. (5.4). The ANSYS finite element program helps in analyzing the stability of
geo- structure (embankment) in varied application of geotextiles reinforcement to enhance the best
design for embankment.
The results of analysis indicate that one of the primary function of geotextiles reinforcement was to
reduce the horizontal displacement significantly. With the inclusions of reinforcement, the horizontal
displacement reduced by about (81%), while the vertical displacement reduced by (32%). The effect
of geotextiles

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Oct 10 2023
Journal Name
Journal Of Craniofacial Surgery
CBCT Analysis of Oropharynx Airway Volume
...Show More Authors
Objective:

The study was performed to analyze the oropharynx airway and examine the influence of age and gender on the oropharynx volume configuration using cone beam computed tomography.

Materials and Methods:

This study examined the cone beam computed tomographic images of 51 patients 25 male and 26 females, group matched for age and gender. The oropharynx airway volume and area between the posterior nasal spine and top of the epiglottis were measured and compared.

Results:
... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Jan 07 2026
Journal Name
Journal Of Baghdad College Of Dentistry
CBCT analysis of impacted maxillary canines
...Show More Authors

Background: This study designed to shade light on the important role of CBCT in accurate localization of the impacted maxillary canines. Materials and method: Fifty two unilateral and bilateral impacted maxillary canines from 30 patients (24 females and 6 males) were evaluated by a volumetric 3D images obtained from cone beam CT. All samples attended to the specialist health center of dentistry in Al-Sadder City referred to CBCT by oral surgeons or orthodontists to detect the exact position of impacted upper canine in cases when there was no bulging buccally or palatally which aids to detect the exact position. Results: Mesio-palatal angulations had the highest rate (63.5%) followed by mesio-labial (19.2%), vertical (labial) (9.6%), disto-p

... Show More
View Publication Preview PDF