Histological and histomorphometric analysis of strontium chloride coated commercially pure titanium implant compared with hydroxyapatite coating
...Show More Authors

Background: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium screws. The tibia of 4 white New Zealand rabbits was chosen as implantation sites. Each tibia of rabbit received two screws, one strontium chloride coated and one hydroxyapatite coated and a total 30 histological sections were obtained for each coating material in each period of time. Histomorphometric analysis was performed to measure new bone formed ratio between implant and original bone, after 2 and 6 weeks healing periods. Results: There was increased in new bone formation ratio for the strontium chloride coated implants than hydroxyapatite coated implants and over the two periods of time. There was an increase in the new bone formation ratio at bone-implant interface with time. Conclusion: Coating commercially pure titanium implant with strontium chloride was more efficient in increasing osseointegration at bone implant interface than hydroxyapatite , which was demonstrated by higher new bone formation and maturation at the two periods of time 2 weeks and 6 weeks after implantation. Keywords: Histomorphometric, commercially pure titanium, strontium chloride, hydroxyapatite.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Effect of Hydroxyapatite Coatings on Corrosion Behavior for Biotype 316L SS Used in Orthopaedic Applications
...Show More Authors

Electrochemical corrosion of hydroxyapatite (HAP) coated performance depends on various parameters like applied potential, time, thickness and sintering temperature. Thus, the optimum parameters required for the development of stable HAP coatings was found by using electrophoretic deposition (EPD) technique. This study discusses the results obtained from open circuit potential-time measurements (OCP-time), potentiodynamic polarisation and immersion tests for all alloy samples done under varying experimental conditions, so that the optimum coating parameters can be established. The ageing studies of the coated samples were carried out by immersing them in Ringer’s solution for a period of 30 days indicates the importance of stable HAP c

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Quantitative assessment of Mutans Streptococci adhesion to coated and uncoated orthodontic archwires(In vitro study)
...Show More Authors

Background: The development of orthodontic biomaterials that attract less biofilm has been a goal for decades. Adhesion and colonization of cariogenic streptococci are considered to play key roles in the development of enamel demineralization related to orthodontic materials. The aim of this study was to quantitatively evaluate the Mutans streptococci adhesion to coated orthodontic archwires (Epoxy and Teflon) and uncoated archwires (stainless steel and nickel-titanium) with respect to incubation time in the presence and absence of saliva. Material and Method: Six types of archwires stainless steel and nickel titanium with two type of coating (Epoxy, Teflon) were used in this study. Twelve specimens of each archwire were incubated in steri

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 10 2018
Journal Name
Ceramics International
Application of zirconia surface coating to improve fracture resistance and stress distribution of zirconia ceramic restorations
...Show More Authors

Zirconia ceramic restoration (ZCR) has a higher fracture incidence rate than metal ceramic restoration. Different surface treatments were used to improve fracture performance of ZCR such as grit blasting (GB) by aluminium oxide powder. This type of surface treatment generate residual stresses on veneering ceramic causing crack initiation and ending with a fracture. In order to overcome the stress generated by GB, zirconia surface coating is used as a surface treatment to improve fracture resistance and to accommodate stresses along the ZCR layers. Fifty zirconia ceramic crowns were fabricated and divided according to the type of surface treatment into three groups; the first group is (ZG), involving 20 cores were coated with a mixture of pa

... Show More
Scopus (4)
Scopus
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Spectrophotometric determination of Procaine penicillin in pure and pharmaceutical formulations using metol
...Show More Authors

A simple, accurate and sensitive spectrophotometric method for the determination of Procaine penicillin (PP) is described. The method is based on charge-transfer reaction of PP with metol (N-methyl-p-hydroxy aniline) in the presence of ferric sulphate to form a purple-water soluble complex ,which is stable and has a maximum absorption at 510 nm .A graph of absorbance versus concentration shows that Beer’s low is obeyed over the concentration range of 3-80 µg /ml of PP (i.e.,3-80 ppm) with a molar absorbativity of 4.945 ×103 L.mol-1.cm-1 ,Sandell sensitivity of 0.1190 µg cm-2 ,a relative error of (-1.57)-2.79 % and a standard deviation of less than 0.59 depending on the concentration of PP.The optimum conditions for full co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrochemical Behavior of Chemical Conversion Coated Aluminum ASA6061 in Chromic Acid
...Show More Authors

The corrosion behavior of bare and chemical conversion coated (through anodizing) aluminum ASA 606 I in stagnant chromic acid solutions . Solutions of 2, 6 & J O wt. % Cr03 at 45°C, have been investigated using polarization technique. The anodizing experiments were conducted under fixed conditions of 35 minute exposure time and 30 volt supplied voltage. The most important feature achieved was the great difference in behavior between the anodic polarization curves for bare and anodized aluminum in different concentrations of chromic acid solutions.

View Publication Preview PDF
Publication Date
Sun Sep 25 2022
Journal Name
Hiv Nursing
BIOSYNTHESIS OF SILVER / SILVER CHLORIDE NANOPARTICLES BY IRAQI PROPOLIS AND STUDY THE ANTI – BACTERIAL ACTIVITY
...Show More Authors

Sliver / Sliver chloride is as old used from human but the sliver / sliver chloride nanoparticles have only recently been recogenized. They have used in medicin and agiculture. In the present study have been investigation the effecte biosynthesis Sliver / Sliver chloride nanoparticles as antibacterial by demonstrated that Ag / AgCl NPs arrest the growth of many bacterial: S.typhimurium, k. pneumonia. S. aureus, L.monocytogenes, B. Anthracis, E. coli, C. frundi, S. Pneumonia, P. Aeruginosa. The elements compestion and crystallization panal of biosynthesized nanoparticles were chracterazated by FTIR, XRD and SEM. From XRD, It is confirmed the synthesized nanoparticles contain Sliver / Sliver chloride elements. Synthesized Ag / AgCl NPs showed

... Show More
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Phosphorus Removal from Water and Waste Water by Chemical Precipitation Using Alum and Calcium Chloride
...Show More Authors

Phosphorus is usually the limiting nutrient for eutrophication in inland receiving waters; therefore, phosphorus concentrations must be controlled. In the present study, a series of jar test was conducted to evaluate the optimum pH, dosage and performance parameters for coagulants alum and calcium chloride. Phosphorus removal by alum was found to be highly pH dependent with an optimum pH of 5.7-6. At this pH an alum dosage of 80 mg/l removed 83 % of the total phosphorus. Better removal was achieved when the solution was buffered at pH = 6. Phosphorus removal was not affected by varying the slow mixing period; this is due to the fact that the reaction is relatively fast.
The dosage of calcium chloride and pH of solution play an importa

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 03 2017
Journal Name
Baghdad Science Journal
A study of histological changes in the Diaphragm of male albino mice administered with aqueous extract of chamomileflowers Chamomillarecutita
...Show More Authors

The chamomile is one of the most important medicinal plants recommended for treatment of asthma and some respiratory system diseases. This research was designed to research the effects of aqueous extract of chamomillarecutita on histological structure of Diaphragm of albino mice. The study included 40 male albino mice Musmusculus, their age ranged from (5-7) weeks.The mices were divided randomly to 5 groups and oral administered with 1 ml every day for 10 days:- First Group G1: consider as control group and treated with normal saline,Second Group G2: was treated with aqueous extract of chamomile with concentration of 3 gm /100 ml D.W, Third Group G3: was treated with aqueous extract of chamomile with concentration of 5 gm /100 ml D.W.Fourth

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Employment of Titanium dioxide thin film on NO2 gas sensing
...Show More Authors
Abstract<p>TiO<sub>2</sub> thin films were deposited by Spray Pyrolysis with thickness ((350±25) nm) onto glass substrates at (350°C), and the film was annealed at temperatures (400 and 500)°C. The structural and morphological properties of the thin films (TiO<sub>2</sub>) were investigated by X-ray diffraction, Field emission scanning electron microscopy and atomic force microscope. The gas sensor fabricated by evaporating aluminum electrodes using the annealed TiO<sub>2</sub> thin films as an active material. The sensitivity of the sensors was determined by change the electrical resistance towards NO<sub>2</sub> at different working temperatures (200 </p> ... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Tue Aug 01 2017
Journal Name
International Journal Of Science And Research
Surface properties of different heat treated titanium alloy dental implants
...Show More Authors

Titanium alloy surface properties have an essential role in the interaction of dental implants with bone, and alteration of the surface of the implant could improve osseointegration. This study was designed to investigate the effect of different heat treatment temperatures on titanium alloy surface properties for dental implants. The effect of different temperatures of heat treatment (750°C, 850°C, 950°C and 1050°C) were investigated on the surface topography, surface chemistry, titanium oxide layer thickness, blood contact angle, & blood drop diameter of titanium alloy. The disks were prepared from titanium alloy (Ti-6Al-4V) and the samples were divided into five groups depending on the different temperatures of heat treatment. The hea

... Show More
Preview PDF