Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um particles size, with polyvinyl alcohol powder of 212-300um particle size, as a space holder, by volume ratio (70:30) % respectively. The mixed powder was compacted using punch and die set -specially designed for this study –under 20 bar then sintering at 900 ºC by the use of argon gas. Twenty smooth titanium implants were prepared of (3.2mm in diameter and 8mm in length) by lathing of commercially pure titanium rod as a control group. The implants were examined by X-ray diffraction (XRD) and scanning electron microscope (SEM), as well as estimation of porosity percentage. For each tibia of the 20 white New Zealand rabbits, one implant of each type (one porous in right, and the smooth in left tibia), were inserted through surgical procedure carried under serial condition. Mechanical test was performed to evaluate the bone-implant interface, after (2 and 6 weeks) healing periods . Results: Porous implants were obtained successfully by powder technology with 52% porosity and pore size 210um 17±. The porous implant showed significantly higher removal torque values when compared to smooth implants at the two different intervals of examination (2,6 weeks) , this proved to be statistically highly significant, also a highly significant difference was noticed for the means of the torque removal values in the same group at different implantation , with no evidence of clinical features of inflammatory reaction with both . Conclusions: Powder technology seemed to be particularly advantageous in fabrication of porous titanium. Porous implant show an increasing bone ingrowth compared with the smooth type represented by higher removal torque for both healing periods (2, 6) weeks . Key words: Porous titanium implant, powder technology, removal torque test.
IT has its impact on all aspects of life, including its planning and operations. Based on the assumption that the plan can adapt any technique as an analytical tool within broader dimensions to include society in general and meet the requirements of that society. They have neutral values, meaning and usefulness rather than being adopted as abstract goals or objectives so that the planner or the decision-maker can benefit greatly from them. This information technology is summarized in three main axes: First: Geographic Information Systems. Second: computer modeling. Third: visual simulation and the Internet. The problem of research is that the decision-making environment of the plan is surrounded by uncertain information-planning conditio
... Show MoreThe aim of this work is to evaluate some mechanical and physical
properties (i.e. the impact strength, hardness, flexural strength,
thermal conductivity and diffusion coefficient) of
(epoxy/polyurethane) blend reinforced with nano silica powder (2%
wt.). Hand lay-up technique was used to manufacture the composite
and a magnetic stirrer for blending the components. Results showed
that water had affected the bending flexural strength and hardness,
while impact strength increased and thermal conductivity decreased.
In addition to the above mentioned tests, the diffusion coefficient
was calculated using Fick’s 2nd law.
This study aims mainly to identify the role of the use of blockchain technology in improving the quality of digital financial reports, answering questions and testing the hypothesis of the study, the researchers relied on the descriptive analytical approach, and to obtain the necessary data a questionnaire was distributed after evaluation to the study community.
The results of the study have shown that the use of blockchain technology helps to provide a high degree of reliability in digital financial reports published to banks over the Internet, ensure the speed of completion and completion, and maintain the privacy and confidentiality of the information contained in the digital financial reports of banks
... Show MoreIn this paper, the effects of subsurface water retention technology (SWRT) on crop coefficient (kc) and crop evapotranspiration (ETc) of eggplant were investigated in sandy loam soil. For this purpose, two treatments plot (with SWRT and without using SWRT) were adopted during 93 days of cultivation. The study was conducted in open field within Al-Fahamah Township, Baghdad, Iraq during summer growing season 2017. The accumulated ETc of eggplant was 403.3 and 515.2 mm for SWRT treatment and control plot, respectively by reduction percentage 21.7 %. The average values of ETc during the growing season were 4.3 and 5.5 mm/day, respectively. The crop coefficients value during the gro
... Show MoreThis research aims to removes dyes from waste water by adsorption using banana peels. The conduct experiment done by banana powder and banana gel to compare between them and find out which one is the most efficient in adsorption. Studying the effects different factors on adsorption material and calculate the best removal efficiency to get rid of the methylene blue dye (MB).
This study was conducted at the field of poultry-Abu Gharib/department of Animal Production/college of agricultural engineering Sciences-university of Baghdad, during the period from 12/10/2019 to 24/11/2019 duration (42 days), to demonstrate the effect of adding different levels of Allicin to broiler diet on Glutathione level in blood and histological of thymus gland, total of 225 Ross 308 chicks was used. Birds were randomly distributed into five treatment groups which were: First treatment T1: without additives to diet (control), other treatments T2, T3, T4, T5 was added Allicin at a rate of (800,600,400,200 mg/Kg diet) respectively, and Allicin was added from first day until the end of the experiment for all addition treatments, results
... Show More