Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um particles size, with polyvinyl alcohol powder of 212-300um particle size, as a space holder, by volume ratio (70:30) % respectively. The mixed powder was compacted using punch and die set -specially designed for this study –under 20 bar then sintering at 900 ºC by the use of argon gas. Twenty smooth titanium implants were prepared of (3.2mm in diameter and 8mm in length) by lathing of commercially pure titanium rod as a control group. The implants were examined by X-ray diffraction (XRD) and scanning electron microscope (SEM), as well as estimation of porosity percentage. For each tibia of the 20 white New Zealand rabbits, one implant of each type (one porous in right, and the smooth in left tibia), were inserted through surgical procedure carried under serial condition. Mechanical test was performed to evaluate the bone-implant interface, after (2 and 6 weeks) healing periods . Results: Porous implants were obtained successfully by powder technology with 52% porosity and pore size 210um 17±. The porous implant showed significantly higher removal torque values when compared to smooth implants at the two different intervals of examination (2,6 weeks) , this proved to be statistically highly significant, also a highly significant difference was noticed for the means of the torque removal values in the same group at different implantation , with no evidence of clinical features of inflammatory reaction with both . Conclusions: Powder technology seemed to be particularly advantageous in fabrication of porous titanium. Porous implant show an increasing bone ingrowth compared with the smooth type represented by higher removal torque for both healing periods (2, 6) weeks . Key words: Porous titanium implant, powder technology, removal torque test.
The research of three-based financial indicators to create value for shareholders, have been identified research problem in a number of the questions revolved around the extent to which it can express its based performance metrics to create value for the essence and the reality of the surveyed enterprises performance, Can the departments surveyed companies to choose the scale or the most harmonizing index and an expression of the actual performance of the company, has the goal of research is to diagnose the strengths and weaknesses in the performance of the surveyed enterprises through the use of a number of based on the concept of creating economic value and the search for the most suitable indicator to the reality of the perfor
... Show MoreABSTRACT Background: Tuberculosis is a worldwide infectious disease in spite of advancement in health care system. Tuberculous lymphadenitis is the most prevalent form of extra pulmonary tuberculosis with predilection of cervical lymph nodes. Objectives: To evaluate the reliability of grey scale ultrasonography together with color Doppler in the diagnosis of cervical tuberculous lymph adenitis and evaluation of early therapeutic response. Subjects and methods:From July 2015 to May 2016 in Al-Karama teaching hospital /Kut city- Wasit-Iraq, 25 patients (14 males and 11 females) with ages range from (6-50) years. Ultrasonography examination was done for all patients and grey scale criteria (distribution, size, shape, echogenicity, echogenic hi
... Show Moreتعد الموازنة الأداة الأساسية لتنفيذ أولويات أية دولة، ويتوجب النظر إليها في ضوء المناخ الاجتماعي والسياسي والاقتصادي، لأنها تساعد في توجيه الاقتصاد لتحقيق النمو ورفع مستوى الرفاهية. اعتمدت وزارة المالية في أعداد الموازنة السنوية بعد 9/4/ 2003 أسلوباً مغايراً لما كان معتمداً في العقود الماضية، إذ كانت هناك موازنتين الأولى الموازنة الجارية، والثانية الموازنة الاستثمارية رغم وجود قانون يحتم إصدار موازنة
... Show MoreCorruption has become the subject of great interest, and the subject of research and scrutiny in recent years, because of its penetration in all fields of life, whether these fields are political, economic, social, and administrative. It is one of the biggest challenges and problems that are facing communities. Therefore, this study is focused on the evaluation of measures implementing the national strategy to combat corruption in Iraq.
This study was launched, first because of its intellectual dimensions to ensure a conceptual presentation of the strategy and operational management in general with a special focus on the processes of implementation and control str
... Show MoreBackground: The present study involved the following parts, the first part is evaluation of the levels of glycated hemoglobin(HbA1c), creatinine, uric acid(UA) and albumin in patients with diabetic nephropathy comparison with the group of healthy as a control group. The second part is the measurement and evaluation of oxidative stress represented in the malondihydehyde(MDA) as a biomarker of oxidative stress as well as the identification of vitamins C and E as an antioxidant in patients with diabetic nephropathy(DN) compared with the healthy group. Objective: The objective of this study is to estimate oxidative stress by calculate malondialdehyd as biomarker and evaluate some vitamins such as vit C and vit E as antioxidants in diabetic neph
... Show MoreBackground: Denture relining is the process of resurfacing of the tissue side of the ill fitting denture, the bond strength at the relining-denture base interface is most important for denture durability.The aim of present study was to evaluate the shear bond strength between the thermosens as relining material and different denture base materials that bonded by thermo fusing liquid. As this corrective procedureis the common chair side procedure in the dental clinic. Material and method: Sixty samples were prepared and divided into three main groups according to the type of denture base materials.Group (A) referred to the heat cure acrylic samples which consisted of 20 samples. Group (B) referred to the high impact acrylic samples which con
... Show MoreIn this research work, a simulator with time-domain visualizers and configurable parameters using a continuous time simulation approach with Matlab R2019a is presented for modeling and investigating the performance of optical fiber and free-space quantum channels as a part of a generic quantum key distribution system simulator. The modeled optical fiber quantum channel is characterized with a maximum allowable distance of 150 km with 0.2 dB/km at =1550nm. While, at =900nm and =830nm the attenuation values are 2 dB/km and 3 dB/km respectively. The modeled free space quantum channel is characterized at 0.1 dB/km at =860 nm with maximum allowable distance of 150 km also. The simulator was investigated in terms of the execution of the BB84 p
... Show MoreThis research aimed to predict the permanent deformation (rutting) in conventional and rubberized asphalt mixes under repeated load conditions using the Finite Element Method (FEM). A three-dimensional (3D) model was developed to simulate the Wheel Track Testing (WTT) loading. The study was conducted using the Abaqus/Standard finite element software. The pavement slab was simulated using a nonlinear creep (time-hardening) model at 40°C. The responses of the viscoplastic model under the influence of the trapezoidal amplitude of moving wheel loadings were determined for different speeds and numbers of cycles. The results indicated that a wheel speed increase from 0.5Km/h to 1.0Km/h decreased the rut depth by about 22% and 24% in conv
... Show MoreOsteoporosis (OP) is a systemic skeletal disorder that is characterized by reduced bone mass and micro-architectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture. The most frequent osteoporotic fractures are fractures of the hip, wrist, and spine. The exact causes of OP are still unknown; several factors contribute to the disorder. Subjects and Methods: This study consists of patient groups, this group (Group A) was composed of 80 postmenopausal women with OP and osteopenia and the patient group was subdivided into two group; First group (GroupA1) was composed of 50 postmenopausal women with OP and the second group (Group A2) composed of (30) Postmenopausal Women with oste
... Show MoreIn this research work, a simulator with time-domain visualizers and configurable parameters using a continuous time simulation approach with Matlab R2019a is presented for modeling and investigating the performance of optical fiber and free-space quantum channels as a part of a generic quantum key distribution system simulator. The modeled optical fiber quantum channel is characterized with a maximum allowable distance of 150 km with 0.2 dB/km at =1550nm. While, at =900nm and =830nm the attenuation values are 2 dB/km and 3 dB/km respectively. The modeled free space quantum channel is characterized at 0.1 dB/km at =860 nm with maximum allowable distance of 150 km also. The simulator was investigated in terms of the execution of the BB84 prot
... Show More