Background: The development of orthodontic biomaterials that attract less biofilm has been a goal for decades. Adhesion and colonization of cariogenic streptococci are considered to play key roles in the development of enamel demineralization related to orthodontic materials. The aim of this study was to quantitatively evaluate the Mutans streptococci adhesion to coated orthodontic archwires (Epoxy and Teflon) and uncoated archwires (stainless steel and nickel-titanium) with respect to incubation time in the presence and absence of saliva. Material and Method: Six types of archwires stainless steel and nickel titanium with two type of coating (Epoxy, Teflon) were used in this study. Twelve specimens of each archwire were incubated in sterilized unstimulated whole saliva (for the study group) and phosphate-buffered saline (for control group) for 2 hours, then incubated with suspension of Mutans streptococci allowed to adhere for (5,90,180 minutes). Adhesion was quantitated by a microbial culture technique by treating the archwires with adhering bacteria with trypsin and enumerating the colony forming unit (CFU) counts of bacteria recovered after cultivation by using Dentocult SM kit. Results: There was significant difference among the tested archwire types in each time interval with the highest bacterial adhesion on the NiTi archwires in the absence of saliva. In the presence of saliva, the results revealed non-significant difference at 5 min. while there was significant difference at 90 min and highly significant difference at 180 min. Conclusion: The adherence of Mutans streptococci was decreased in the presence of saliva on different archwires and the extended incubation time was significantly related to increase colony forming unit of Mutans Streptococci.
The paper discusses the structural and optical properties of In2O3 and In2O3-SnO2 gas sensor thin films were deposited on glass and silicon substrates and grown by irradiation of assistant microwave on seeded layer nucleated using spin coating technique. The X-ray diffraction revealed a polycrystalline nature of the cubic structure. Atomic Force Microscopy (AFM) used for morphology analysis that shown the grain size of the prepared thin film is less than 100 nm, surface roughness and root mean square for In2O3 where increased after loading SnO2, this addition is a challenge in gas sensing application. Sensitivity of In2O3 thin film against NO2 toxic gas is 35% at 300oC. Sensing properties were improved after adding Tin Oxide (SnO2) to be mo
... Show MoreThis research is an attempt to unveil the cover and unveil a matter that has become mysterious to those who came after Sibweh of the grammar scholars; It took place as a result of the work of the scribes.
In this paper, wavelets were used to study the multivariate fractional Brownian motion through the deviations of the random process to find an efficient estimation of Hurst exponent. The results of simulations experiments were shown that the performance of the proposed estimator was efficient. The estimation process was made by taking advantage of the detail coefficients stationarity from the wavelet transform, as the variance of this coefficient showed the power-low behavior. We use two wavelet filters (Haar and db5) to manage minimizing the mean square error of the model.
A novel demountable shear connector is proposed to link a concrete slab to steel sections in a way that resulting steel-concrete composite floor is demountable, i.e. it can be easily dismantled at the end of its service life. The proposed connectors consist of two parts: the first part is a hollow steel tube with internal threads at its lower end. The second part is a compatible partially threaded bolted stud. After linking the stud to the steel section, the hollow steel tube can be fastened over the threaded stud, which create a complete demountable shear connector. The connector is suitable for use in both composite bridges and buildings, and using cast in-situ slabs, precast solid slabs, or hollow-core precast slabs. A series of push-off
... Show MoreAbstract
The aim of this paper is to investigate and discuss the mechanisms of corrosion of epoxy coatings used for potable water tanks. Two distinct types of Jotun epoxy coatings: Tankguard 412 contained polyamine cured epoxy and Penguard HB contained polyamide cured epoxy, were tested and studied using the electrochemical impedance spectroscopic (EIS) method. The porosity of epoxy coatings was determined using EIS method. The obtained results showed that the two epoxy coatings have excellent behavior when applied and tested in potable water of Basrah city. Polyamine is more resistance to water corrosion compared to polyamide curing epoxy and has high impedance values. Microscopic inspection after te
... Show MoreObjective(s): To evaluate nurses’ Practice toward neonatal endotracheal suctioning procedure, and to determine the effectiveness of the interventional program on nurses’ practices, as well as to find out the relationship between nurses’ practice and their demographic characteristics.
Methodology: A Pre-experimental, one group design, was carried out to achieve the objectives of the current study using the evaluation approach and the implementation of the education program for the period from January 17 to June 31, 2022. A non- probability, purposive sample of (24) nurses were selected from the Neonatal Intensive Care Unit at Pediatric Teaching Hospital/ Medical City Department. A checklist w
... Show MoreThis paper proposes a novel finite-time generalized proportional integral observer (FTGPIO) based a sliding mode control (SMC) scheme for the tracking control problem of high order uncertain systems subject to fast time-varying disturbances. For this purpose, the construction of the controller consists of two consecutive steps. First, the novel FTGPIO is designed to observe unmeasurable plant dynamics states and disturbance with its higher time derivatives in finite time rather than infinite time as in the standard GPIO. In the FTGPO estimator, the finite time convergence rate of estimations is well achieved, whereas the convergence rate of estimations by classical GPIO is asymptotic and slow. Secondly, on the basis of the finite and fast e
... Show More