Background: The main purpose of this study is to find if there is any correlation between the level of C-reactive protein (CRP) in gingival crevicular fluid with its serum level in chronic periodontitis patients and to explore the differences between them according to the probing depth. Materials and methods: Forty seven male subjects enrolled in this study. Thirty males with chronic periodontitis considered as study group whom further subdivided according to probing depth into subgroup 1 with pocket depth ≤6mm, subgroup 2 with pocket depth >6mm. The other 17 subjects considered as controls. For all subjects, clinical examination where done for periodontal parameters plaque index (PLI), gingival index (GI), bleeding on probing (BOP), probing pocket depth (PPD) and clinical attachment level (CAL). The gingival crevicular fluid (GCF) were collected using filter paper size 30 from gingival sulcus of the controls and from (138) pocket site (75 sites > 6mm. and 63 ≤ 6mm.). The weight of the GCF was measured by reading the difference in the weight of filter paper before and after absorption of GCF. Crevicular level of CRP was measured calorimetrically. The serum level CRP was measured using latex test. Results: Highly significant difference in the weight of GCF, crevicular and serum level of CRP between chronic periodontitis and control groups. Subgroup 2 got higher scores of weight of GCF and positive record of crevicular and serum CRP compared with subgroup 1 with a non-significant difference. A highly significant difference in the number of sites with positive crevicular and serum CRP compared to the negative number between chronic periodontitis and control groups also between subgroup1 and subgroup 2. Weight of GCF gets a negative significant correlation with GI at control group and subgroup2. Serum level of CRP exhibits a negative significant correlation with PLI for chronic periodontitis and control group and positive significant correlation for GI at subgroup 1. The crevicular CRP get significant negative correlation with GI of subgroup 1. Conclusions: Crevicular fluid is very good marker for the degree of inflammation of the periodontal pocket. The crevicular level of CRP may be considered as a good tool for estimating the systemic effect and predictor for the effect of periodontitis on the general health and the correlation of crevicular with serum CRP aid to high light this effect.
Prosthetic hands are compensatory devices for the hand amputees as a result of injury, various accidents or birth deformities, types of prosthetic hand vary depending on the mechanism they operate and how they perform. There are common types in use that are characterized by their complex mechanisms, which are difficult for the amputee to use or exclude use because of their high cost, therefore the aim of this research is to design an artificial hand that is suitable in terms of simplicity of use and low cost and similar to a natural hand with regard to dimensions and shape that operated in the mechanism of links. This research involves Stress and strain analysis of the prosthetic hand and its fingers that modelled from (Petg CR)
... Show MorePseudomonas aeruginosa, a ubiquitous environmental organism, is a difficult-to-treat opportunistic pathogen due to its broad-spectrum antibiotic resistance and its ability to form biofilms. In this study, we investigate the link between resistance to a clinically important antibiotic, imipenem, and biofilm formation. First, we observed that the laboratory strain P. aeruginosa PAO1 carrying a mutation in the oprD gene, which confers resistance to imipenem, showed a modest reduction in biofilm formation.We also observed an inverse relationship between imipenem resistance and biofilm formation for imipenem-resistant strains selected in vitro, as well as for clinical isolates.We identified two clinical isolates of P. aeruginosa from the sputum
... Show MoreEprospective study undertaken between January 2007 and January 2011, 58 consecutive cases with compound tibial shaft fractures. All fractures were stabilized by external fixator device AO/ASIF type after failed the manipulation under anesthesia (MUA) to restore the osseous alignment. In 32 patients cancellous bone graft were used from the upper part of the tibia to enhance healing process, all these patients were followed for an average of 8–12 months. Our findings showed that stabilization of the fracture shaft tibia by external fixation with cancellous bone graft had significantly better result, than external fixation alone. We conclude that unilateral, uniplanar external fixation with early bone grafting from upper part of the tibia is
... Show MoreIn this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. In order to investigate the response of soil and footing to steady state dynamic loading, a physical model was manufactured. The manufactured physical model could be used to simulate steady state harmonic load at different operating frequencies. Total of (84) physical models were performed. The parameters that were taken into considerations include loading frequency, size of footing and different soil conditions. The footing parameters were related to the size of the rectangular footing and depth of embedment. Two sizes of rectangular steel model footing were used (100 200 12.5 mm) and (200 400 5.0 mm).
... Show MoreForty – two elderly hypothyroidism patients and forty – two apparently healthy as control groups , divided to (21) male (M) and (21) female (F) also (21) control male C(M) and (21) control female C(F) aged > 60 years, were tested for the presence of thyroid peroxidase autoantibody (TPo – Ab) and thyroglobulin auto antibody (Tg – Ab) , also for Se and Zn levels in their sera . The results revealed a significant increase in (TPO – Ab) and (Tg – Ab) for group (M) and (F) compared to control group , also a siginificant increase in TPo – Ab and Tg – Ab for (F) compared to (M) was found. A significant decrease in Se and Zn level for (M) and (F) compared to control group, while no significant difference between (M) and (F). In conc
... Show MoreThis paper presents ABAQUS simulations of fully encased composite columns, aiming to examine the behavior of a composite column system under different load conditions, namely concentric, eccentric with 25 mm eccentricity, and flexural loading. The numerical results are validated with the experimental results obtained for columns subjected to static loads. A new loading condition with a 50 mm eccentricity is simulated to obtain additional data points for constructing the interaction diagram of load-moment curves, in an attempt to investigate the load-moment behavior for a reference column with a steel I-section and a column with a GFRP I-section. The result comparison shows that the experimental data align closely with the simulation
... Show MoreThis study aimed at evaluating the torsional capacity of reinforced concrete (RC) beams externally wrapped with fiber reinforced polymer (FRP) materials. An analytical model was described and used as a new computational procedure based on the softened truss model (STM) to predict the torsional behavior of RC beams strengthened with FRP. The proposed analytical model was validated with the existing experimental data for rectangular sections strengthened with FRP materials and considering torque-twist relationship and crack pattern at failure. The confined concrete behavior, in the case of FRP wrapping, was considered in the constitutive laws of concrete in the model. Then, an efficient algorithm was developed in MATLAB environment t
... Show MoreThis paper performance for preparation and identification of six new complexes of a number of transition metals Cr (lII), Mn (I1), Fe (l), Co (II), Ni (I1), Cu (Il) with: N - (3,4,5-Trimethoxy phenyl-N - benzoyl Thiourea (TMPBT) as a bidentet ligand. The prepared complexes have been characterized, identified on the basis of elemental analysis (C.H.N), atomic absorption, molar conductivity, molar-ratio ,pH effect study, I. Rand UV spectra studies. The complexes have the structural formula ML2X3 for Cr (III), Fe (III), and ML2X2 for Mn (II), Ni (II), and MLX2 for Co (Il) , Cu (Il).