Preferred Language
Articles
/
jbcd-602
Assessment of bone density after six months from dental implants placement using Computed Tomography
...Show More Authors

Background: Determination of local bone mineral density (BMD) immediately after implant insertion play an important role in implant success rate, may offer comprehensive description of the bone, and give enough information to the surgeon prior to implant insertion and at follow up status. The aim of the present study is to evaluate the changes of local bone density in the dental implant recipient sites by using computerized tomography. Material and method: The sample consisted of (20) dental implants recipient sites, bone density assessment was done twice, immediately after implants insertion and after six months. Results: The mean HU of the bone around the implant insertion site, immediately after implant placement was 552.28 HU, and increased to761.33HU after six months. According to gender, with females, it was 539,54HU, and increased to 765.65HU after six months from implant insertion while with males, it was 565.02HU, and increased to 757.02HU after six months from implant insertion. Conclusion: There was an increased in bone density around dental implant by time with non-significant differences according to the gender.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Political Sciences Journal
Affecting factors in Yemeni - Russian Relations after 2011
...Show More Authors

Thethesis of theresearch is to deal with relations between Russia and Yemen after 2011.That relationwas significant in different fields, historic, economic, strategic and cultural ones. There are mutual interestsbetweenRussia and Yemen, especially with the economic development and growth in Russia as an important partner to Yemen.Their has to an a great deal of progress in different types of relations, where as they were only partner in military relations. The studywasclassifiedintoto three sections: the first section dealt with strategic importance of Yemen to Russia. And second section dealt withthe military factor between Russia and Yemen. While the third section dealt with the economic factor between Russia and Yemen. In addi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 30 2025
Journal Name
مجلة دراسات دولية
China-Russia relations after 2013: motives and determinants
...Show More Authors

This research aims to identify the reality of Sino-Russian relations after 2013, and to study the most important motives and determinants that affected the nature of these relations. The research was based on the criterion of national interest in interpreting and understanding relations between China and Russia, on the basis that national interest is what determines the state of cooperation and dependence, or the state of competition and difference. The research was based on the hypothesis that Sino-Russian relations after 2013 witnessed many factors and variables, some of which represented motives for strengthening relations between the two countries, and others represented obstacles that limit the level of cooperation and interaction betw

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Histological Evaluation of Effect of beta-Tricalcium Phosphate on Bone healing in Alloxan-Induced diabetes
...Show More Authors

Background: Improved glucose level control with insulin injections have allowed for the diabetic population to live longer and healthier lives. Unfortunately diabetes remains a worldwide epidemic disease with multiple health implications. Specifically, its effects upon fracture healing are compromised in diabetics with as high as 87% recovery delay relative to “healthy” counterparts. Current medical treatments for bone injuries have been largely focused on replacing the lost bone with allogenic or autogenous bone grafts, beta-tricalcium phosphate (β -TCP), a ceramic alloplast, has interconnected system of micropores, has been widely used as a biologically safe osteoconductive bone substitute. The aim of this study was histol

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Political Sciences Journal
Handicaps of reconstructing Iraqi strategic capabilities after 2003 (Analytical vision )
...Show More Authors

Abstract: The issue of rebuilding the strategiccapacity of Iraq after the occupation and the US invasion in 2003 has been oneof the most contentious issues of debate and debate. It raises a number ofpolitical, social, economic, military and security problems. We say politicalprimarily because the climate and political conditions play a large and activerole along with other factors complementary to them. The important questionthat arises here is: How can the ruling political blocs move to the stage ofreconstruction without reservations? In order to answer this question, wedivided the study into three main axes. The first deals with the concept ofpower and its types. The second axis deals with the relationship betweenstrategic capa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Nov 29 2013
Journal Name
Arabian Journal Of Geosciences
Cd, Ni, and Pb distribution and pollution assessment in roadside dust from Baghdad City and Western Iraqi Desert
...Show More Authors

View Publication
Crossref (11)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Research Journal Of Pharmacy And Technology
Electro-polymerization of poly eugenol on ti and ti alloy dental implant treatment by micro arc oxidation using as anti-corrosion and anti-microbial
...Show More Authors

In this work, electrochemical process was presented to polymerized eugenol on Gr.2 and Gr.5 titanium alloys before and after treated by Micro Arc Oxidation (MAO), where Gr.2 is commercial pure titanium and Gr.5 is Ti-6Al-4V dental alloys. The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of polymeric thin-film was estimation by using pull-off adhesion test and the result was the adhesion strength of PE was (1.23 MPa) on Gr.2 before MAO and increase to (1.98 MPa) on Gr.2 after MAO treatment. The corrosion behavior of Gr.2 and Gr.5 alloy in artificial saliva environment at

... Show More
View Publication
Scopus (25)
Crossref (10)
Scopus Crossref
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Reliability of the multipeg™ transducer in measuring dental implant stability by using a resonance frequency analysis device (Osstell®): An observational clinical study
...Show More Authors

Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Sat Mar 03 2018
Journal Name
International Journal Of Science And Research
In Vivo Mechanical and Histological Evaluation of the Effect of Vacuum Storage and Ultra Violet Light Treatment of Titanium Implants on Osseointegration
...Show More Authors

Background: Titanium implant is widely used in dentistry because of its extraordinary biocompatibility and mechanical properties. To increase bone–implant connection and provide early loading after placement, implant is stored in different storage medium and treated with UV light. Both of them are applicable methods to increase the bioactivity of titanium and overcome the biological aging. This study was designed to assess the effect of vacuum storage method and air storage with and without UV light treated of Cp Ti implant mechanically and histologically. Materials and methods: Titanium screws were acid etched and prepared in four different modes using different storage methods (air or vacuum and, with or without UV treatment. The implan

... Show More
Preview PDF
Publication Date
Sat Dec 05 2015
Journal Name
International Journal Of Dental And Health Sciences
IRRATIONAL ANTIBIOTIC ADMINISTRATION AMONG IRAQI PATIENT ATTENDING DENTAL CLINIC
...Show More Authors

ABSTRACT: In dental practice there are many wrong habits that should be recognized and treated. One of them is the irrational antibiotic (AB) administration by patient. This indeed created an important issue in dental clinics first of all drug resistance and super infection. This was analyzed in our study and then the causes were identified and a plan suggested in recommendation hope that it will minimize the outcomes. Results: all those patients were finally subjected to be clinically diagnosed and treated this lead to only one fact, these antibiotics are not effective in one way or another since they are not prescribed by dentist

View Publication
Publication Date
Mon Apr 01 2019
Journal Name
Dental Materials
An integrated multifunctional hybrid cement (pRMGIC) for dental applications
...Show More Authors

Objective. Glass-ionomer and resin-modified glass-ionomer cements are versatile materials with the ability to form a direct bond with tooth tissues. The aim of this study was to formulate a novel class of dental bio-interactive restorative material (pRMGIC) based on resin-modified glass-ionomer cements via the inclusion of an organophosphorus monomer, ethylene glycol methacrylate phosphate, with a potential to improve the mechanical properties and also function as a reparative restorative material. Methods. pRMGIC was formulated with modification of the resin phase by forming mixes of ethylene glycol methacrylate phosphate (EGMP; 0–40%wt) and 2-hydroxyethyl methacrylate monomer into the liquid phase of a RMGIC (Fuji II LC, GC Corp.).

... Show More
View Publication
Scopus (7)
Crossref (8)
Scopus Clarivate Crossref