Background: The repair of bone defects remains a major clinical orthopaedic challenge. Bone is a highly vascularised tissue reliant on the close spatial and temporal connection between blood vessels and bone cells to maintain skeletal integrity. Angiogenesis thus plays a pivotal role in skeletal development and bone fracture repair. The role of angiogenic and osteogenic factors in the adaptive response and interaction of osteoblasts and endothelial cells during the multi step process of bone development and repair will be highlighted in this study. This study aimed to identify the role of local exogenous vascular endothelial growth factor in bone healing and to analyze the expression of VEGF by immunohistochemistry in created bone defect after application with different biomaterials in a rat model. Materials and methods: In this experimental study eighteen male Albino rats, weighing (300-400) gram, aged (6-8) months were used and maintained under control conditions of temperature, drinking and food consumption. The animals were subjected for a surgical operation of medial sides of both tibiae bone ( right side was considered as experimental site ,while left be the control one), in control group the bone defect treated with local application of 1µm of normal saline, while experimental treated with local application of 1µm of VEGF .The rats were sacrificed at 3,7,10 days after surgery(six rats for each period). Bone healing was histologically examined with immunohistochemical localization of VEGF Results: Bone defect treated with local application of VEGF shows an early osteoid tissue deposition with high cell count for osteoblast, osteocyte and osteoclast. Immunohistochemical evaluation for VEGF by stromal cells, reported to be higher with significant difference in VEGF group in comparison to control. Conclusion: The study illustrated that low application of VEGF could be an effective therapeutic expression for bone injuries; these data are promising for a possible future clinical usage.
In the present research, the electrical properties which included the ac-conductivity (σac), loss tangent of dielectric (tan δ) and real dielectric constant (ε’) are studied for nano polycarbonate in different pressures and frequencies as a function of temperature these properties were studied at selective temperature gradients which are (RT-50-100-150-250)°C. The results of the study showed that the values of dielectric constant and dissipation factor increase with increasing pressure and temperature and decreases by increasing frequency. And the results of electrical conductivity showed that it increases with increasing temperature, pressure and frequency.
This study aims to Statement of the relationship between Total Quality Management philosophy and Organizational performance from the point of view of the internal customer. A comparison has been made between two companies, one of which applies the requirements of TQM well and the other does not apply these requirements as the (General Company for Electrical Industries/ Diyala) and (General Company for Electrical Industries/ Baghdad) to conduct the search, During the questionnaire prepared for this purpose and distributed to a sample of 30 employees in the General Company for Electric Industries/ Diyala and (20) employees of the General Company for Electrical Industries/ Baghdad. Their answers were analyzed using a simple correlation coef
... Show MoreBackground: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i
... Show MoreMany designs have been suggested for unipolar magnetic lenses based on changing the width of the inner bore and fixing the other geometrical parameters of the lens to improve the performance of unipolar magnetic lenses. The investigation of a study of each design included the calculation of its axial magnetic field the magnetization of the lens in addition to the magnetic flux density using the Finite Element Method (FEM) the Magnetic Electron Lenses Operation (MELOP) program version 1 at three different values of current density (6,4,2 A/mm2). As a result, the clearest values and behaviors were obtained at current density (2 A/mm2). it was found that the best magnetizing properties, the high
... Show MoreThe invasion and spread of cancer cells are two of the most notable characteristics of malignant tumors. Recent studies suggest that the epithelial-mesenchymal transition (EMT) has been linked to this significant occurrence. It is linked to the absence of the epithelial brow and the presence of mesenchymal facial hair. The aims of the present study were to explore the immunohistochemical staining of vimentin and E-cadherin ex vivo as EMT markers and assess their potential as predictive biomarkers for transitional cell cancer (TCC). In this study, 55 paraffin-embedded biopsies from TCC patients and 10 autopsies that appeared to be normal were included. Immunohistochemistry was used to produce patterns of vimentin and E-cadherin expression. W
... Show MoreThis study was conducted to determine the effects of concentration of hydrochloric acids, temperature, and time on the hydrolysis of soya proteins (defatted soya flour) by determining the value of total protein nitrogen concentration, and amino nitrogen concentration of protein, peptides, and amino acids, and then calculated the hydrolysis rate of proteins.
The variables of the conditions of hydrolysis process was achieved in this study with the following range value of tests parameter:
- Concentration of HCl solution ranged between 1-7 N,
- Hydrolysis temperature ranged between 35-95 °C, and
- The time of hydroly