Preferred Language
Articles
/
jbcd-595
Shear bond strength of endodontic sealers to dentin with and without smear layer and gutta percha (An in vitro study)
...Show More Authors

Background: The bond strength of root canal sealers to dentin and gutta-percha seems to be an important property for maintaining the stability of root canal filling, which potentially influences both leakage and root strength. The objective of this, in vitro, study was to evaluate the shear bond strength of three different endodontic sealers (Gutta-Flow, AH Plus, Apexit Plus) to dentin, in the presence and absence of the smear layer and gutta percha. Material and Methods: After slicing off the occlusal 2mm of 60 extracted human maxillary premolar teeth, the exposed dentin served as the tested surfaces; the teeth were fixed with cold cure acrylic, and were divided into two groups according to the smear layer presence, group A without smear layer, when dentin surfaces were irrigated with EDTA 17% followed by distilled water then subdivided into 3 subgroups according to the type of sealer used; group B when dentin surfaces were washed with distilled water only, then subdivided into 3 subgroups. Thirty samples of gutta-percha were prepared and named as group C which was subdivided into 3 subgroups. Five mm long section of polyethylene tubes were placed on the dentin or gutta percha surfaces and filled with freshly mixed sealer. After one week, all the samples were tested for shear bond strength by the Instron Universal Testing Machine at a cross head speed of 0.5 mm/min. The data was calculated in MPa and was statistically analyzed Result: There was a highly significant difference in the shear bond strength (P < 0.05) in comparison among the tested groups, GuttaFlow showed non-significant difference in bond strength to dentin with and without smear layer, while AH Plus and Apexit Plus showed a high significant difference. Conclusions: AHPlus showed the highest shear bond strength in all the tested samples, while GuttaFlow was the least. Additionally, AH Plus and Apexit Plus shear bond strengths were affected by the smear layer removal, while GuttaFlow was not.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 01 2012
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Bank credit and the most important ratios related to the granting: An analytical study of the company advanced Petrokimot Saudi Arabia
...Show More Authors


  Bank credit is extremely important, as the generated revenues by a main focus of any bank earnings no matter how many and varied sources of revenue other, and without losing the bank and the main role function as an intermediary in financial economics . But at the faltering customers in payment of loans .   Therefore , uses a method of financial analysis using ratios as one of the important tools to measure the clients ability to pay , in spite of the need for the Bank analyzed the trend in this regard is focused on three main areas ( liquidity, profitability, and borrowing ) and can be to add another field is the possibility to cover fixed charges of the profits generated.   Finally I would like to emphas

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2013
Journal Name
Experimental Parasitology
An Acanthamoeba castellanii metacaspase associates with the contractile vacuole and functions in osmoregulation
...Show More Authors

View Publication
Scopus (11)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
Experimental Study on Heat Transfer and Friction Factor Characteristics of Single Layer Graphene Based DI-water Nanofluid in a Circular Tube under Laminar Flow and Different Heat Fluxes as Boundary Conditions
...Show More Authors

An experimental study was performed to estimate the forced convection heat transfer performance and the pressure drop of a single layer graphene (GNPs) based DI-water nanofluid in a circular tube under a laminar flow and a uniform heat flux boundary conditions. The viscosity and thermal conductivity of nanofluid at weight concentrations of (0.1 to 1 wt%) were measured. The effects of the velocity of flow, heat flux and nanoparticle weight concentrations on the  enhancement of the heat transfer are examined. The Nusselt number of the GNPs nanofluid was enhanced as the heat flux and the velocity of flow rate  increased, and the maximum Nusselt number  ratio (Nu nanofluid/ Nu base fluid)   and thermal performance factor

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Structures
Horizontal pushout tests and parametric analyses of a locking-bolt demountable shear connector
...Show More Authors

A ‘locking-bolt’ demountable shear connector (LBDSC) is proposed to facilitate the deconstruction and reuse of steel-concrete composite structures, in line with achieving a more sustainable construction design paradigm. The LBDSC is comprised of a grout-filled steel tube and a geometrically compatible partially threaded bolt. The latter has a geometry that ‘locks’ the bolt in compatible holes predrilled on the steel flange and eliminates initial slip and construction tolerance issues. The structural behaviour of the LBDSC is evaluated through nine pushout tests using a horizontal test setup. The effects of the tube thickness, strength of concrete slab, and strength of infilled grout on the shear resistance, initial stiffness, and du

... Show More
View Publication
Scopus (42)
Crossref (42)
Scopus Clarivate Crossref
Publication Date
Wed Dec 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Tensile force measurement by using different lingual retainer wires, bonding materials types and thickness (A comparative in vitro study)
...Show More Authors

Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H O

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 02 2014
Journal Name
Baghdad Science Journal
An Ecological and Identification Study for Algae in Groundwater of Selected Area in Tikrit city and It’s Surrounding Area
...Show More Authors

The present study is carried out to identify the algae in the groundwater of the three areas of Tikrit city, including (the center of Tikrit , the region of AL-Jazira , Awainat village) by nine wells, a depths ranged between 9 meter at well 8 and 110 meter at wells 3 and 5 . And examined the environmental characteristics of physical, chemical and biological factors during the study period from September 2009 to June 2010. It is obtained that wells in the study area is lower alkalinity, average it ranged (6.448-7.418). It was noted that the values of the dissolved oxygen are few and almost non-existent in some cases it ranged between (6.5-6.3)mg/l , analysis of biological oxygen demand refers to wells water (clean- very clean) average

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon May 23 2016
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Iraqi Pharmaceutical Formula for Clonazepam Oral Drop 2.5 mg/ ml to Treat Seizure Epilepsy in Infants and Children with its Stability Study.: Iraqi Pharmaceutical Formula for Clonazepam Oral Drop 2.5 mg/ ml to Treat Seizure Epilepsy in Infants and Children with its Stability Study.
...Show More Authors

This work has been carried out to develop national drug product contains 2.5mg/ml clonazepam as oral drop; it is used for the treatment of epilepsy in infants and children.
Several formulations were prepared using oral drop base, flavor, buffer, sweeteners and preservatives. Selection of best formula relied solely on physic-chemical testing of samples.
Stability study was conducted on the product for six months at different temperatures to determine the expiration date and the best storage conditions.
From the study we obtained an oral drop of good clear solution. The expiry date calculated to be not less than 2 years.

View Publication Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
A GENERAL VELOCITY PROFILE FOR A LAMINAR BOUNDARY LAYER OVER FLAT PLATE WITH ZERO INCIDENCE
...Show More Authors

A general velocity profile for a laminar flow over a flat plate with zero incidence is obtained by employing a new boundary condition to the other available boundary conditions. The general velocity profile is mathematically simple and nearest to the exact solution. Also other related values, boundary layer thickness, displacement thickness, momentum thickness and coefficient of friction are nearest to the exact solution compared with other corresponding values for other researchers.

View Publication Preview PDF
Crossref
Publication Date
Sat Mar 23 2024
Journal Name
Journal Of Optics
Tapered single-mode no-core optical fiber sensor coated with layer gold for hemoglobin sensing
...Show More Authors

The present work focuses on the experimental implementation of one of the fiber optical sensors, the optical glass fiber built on surface Plasmon resonance. A type of optical glass fiber was used in this work, single-mode no-core fiber with pre-tapering diameter: (125.1 μm) and (125.3 μm), respectively. The taper method can be tested by measuring the output power of the optical fiber before and after chemical etching to show the difference in cladding diameter due to the effect of hydrofluoric acid with increasing time for the taper process. The optical glass fiber sensor can be fabricated using the taper method to reduce the cladding diameter of the fibers to (83.12 µm, 64.37 µm, and 52.45 µm) for single-mode fibers using Hydrofluoric

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
A GENERAL VELOCITY PROFILE FOR A LAMINAR BOUNDARY LAYER OVER FLAT PLATE WITH ZERO INCIDENCE
...Show More Authors

A general velocity profile for a laminar flow over a flat plate with zero incidence is obtained by employing a new boundary condition to the other available boundary conditions. The general velocity profile is mathematically simple and nearest to the exact solution. Also other related values, boundary layer thickness, displacement thickness, momentum thickness and coefficient of friction are nearest to the exact solution compared with other corresponding values for other researchers.

View Publication Preview PDF