Preferred Language
Articles
/
jbcd-592
Evaluation of marginal gap at the composite/enamel interface in Class II composite resin restoration by SEM after thermal and mechanical load cycling (An in vitro comparative study)
...Show More Authors

Background: This study compared in vitro the marginal adaptation of three different, low shrink, direct posterior composites Filtek™ P60 (packable composite), Filtek™ P90 (Silorane-based composite) and Sonic fill™ (nanohybrid composite) at three different composite/enamel interface regions (occlusal, proximal and gingival regions) of a standardized Class II MO cavity after thermal changes and mechanical load cycling by scanning electron microscopy. Materials and methods:Thirty six sound human maxillary first premolars of approximately comparable sizes were divided into three main groups of (12 teeth) in each according to the type of restorative material that was used: group (A) the teeth were restored with Filtek™ P60 and single bond™ Universal adhesive using horizontal incremental technique, group (B)the teeth were restored with Filtek™ P90 and P90 system adhesive using horizontal incremental technique and group (C) the teeth were restored with Sonic fill™ composite and single bond™ Universal adhesive using bulk technique.After specimens were stored in distilled water at 37°C for 7 days, all specimens were subjected to thermocycling at (5° to 55 °C), then submitted to mechanical load cycling (intermittent axial force of 49N and a total of 50.000 cycles). The specimens were observed under scanning electron microscope at (2000 X) to measure marginal gap width (the distance between the dental wall and the restoration) at occlusal, proximal and gingival regions in micrometer using Tescan software, version 3.5. Data were analyzed statistically by one way ANOVA test and least significant difference tests. Results:The results showed that the silorane-based posterior composite (Filtek™ P90) showed significantly the least marginal gap width at the occlusal, proximal and gingival regions after the application of thermal changes and mechanical load cycling in comparison to the two methacrylate-based posterior composite Filtek™ P60 (packable) and the Sonic fill™ (nano-hybrid). Sonic fill™ bulk fill composite that relied on the vibration concept to lower the viscosity of high filler loaded composite material showed significantly lesser marginal gaps width at occlusal, proximal and gingival composite/enamel interface regions in comparison with Filtek™ P60 (packable composite) using horizontal incremental technique. The silorane-based composite (Filtek™ P90) showed non-significant difference in marginal gaps width at the three different regions. While, both methacrylate based Filtek™ P60 and Sonic fill™ composite showed significantly lesser marginal gap width at the occlusal region in comparison with gingival regions. Conclusion: None of the low-shrinkage composite restorative materials tested in this study totally prevented micro-gap formation at composite/enamel interfaces of Class II MO cavity.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 25 2023
Journal Name
International Journal Of Drug Delivery Technology
Synthesis, Characterization, Antioxidant and Antibacterial Studies for New Schiff Base Complexes derived from 4-Bromo-O-toluidine
...Show More Authors

In this article, new Schiff base ligand LH-prepared Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), Hg(II), Pd(II), and Pt(II) materials were analyzed using spectroscopy (1 Metal: 2 LH). The ligand was identified using techniques such as FTIR, UV-vis, 1H-13C-NMR, and mass spectra, and their complexes were identified using CHN microanalysis, UV-vis and FTIR spectral studies, atomic absorption, chloride content, molar conductivity measurements, and magnetic susceptibility. According to the measurements, the ligand was bound to the divalent metal ions as a bidentate through oxygen and nitrogen atoms. The complexes that were created had microbicide activity against two different bacterial species and one type of fungus. DPPH techniques were bei

... Show More
Publication Date
Thu Oct 18 2018
Journal Name
European Journal Of Organic Chemistry
PdII-Mediated Oxidative Amination for Access to a 9-Azabicyclo[4.2.1]nonane Compound Library and Anatoxin-a
...Show More Authors

View Publication Preview PDF
Crossref (5)
Clarivate Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Iaes International Journal Of Artificial Intelligence (ij-ai)
Design and implementation monitoring robotic system based on you only look once model using deep learning technique
...Show More Authors

<span lang="EN-US">The need for robotics systems has become an urgent necessity in various fields, especially in video surveillance and live broadcasting systems. The main goal of this work is to design and implement a rover robotic monitoring system based on raspberry pi 4 model B to control this overall system and display a live video by using a webcam (USB camera) as well as using you only look once algorithm-version five (YOLOv5) to detect, recognize and display objects in real-time. This deep learning algorithm is highly accurate and fast and is implemented by Python, OpenCV, PyTorch codes and the Context Object Detection Task (COCO) 2020 dataset. This robot can move in all directions and in different places especially in

... Show More
View Publication
Scopus (13)
Crossref (4)
Scopus Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Relationship between very low birth weight neonates and increased neonatal mortality for age 0 to 7 days
...Show More Authors

Background: Very low birth weight (VLBW) neonates constitute approximately 4–7 percent of all live births and their mortality is very high.
Objective: to find out if there is a relationship between Very Low Birth Weight Neonates and increased neonatal mortality for age 0 to 7 days.
Methods: A retrospective study of VLBW neonates admitted to NICU at Ibn Al- Baladi Pediatrics and Maternity hospital over one year (2012)were studied, The study period was from April till August 2013. Exclusion criteria were: (1) neonates weighing less than 700 g and with gestational age less than 24 weeks (abortion) (2) death in the delivery room (3) neonates weighing more than 1500 g. (4) Postnatal age more than 7 days. The outcome measure was in-hos

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Emulsion Liquid Membrane for Pesticides Removal from Aqueous Solution: Emulsion Stability, Extraction Efficiency and Mass Transfer Studies
...Show More Authors

The current study investigated the stability and the extraction efficiency of emulsion liquid membrane (ELM) for Abamectin pesticide removal from aqueous solution. The stability was investigated in terms of droplet emulsion size distribution and emulsion breakage percent. The proposed ELM included a mixture of corn oil and kerosene (1:1) as a diluent, Span 80 (sorbitan monooleate) as a surfactant and hydrochloric acid (HCl) as a stripping agent without utilizing a carrier agent. Parameters such as homogenizer speed, surfactant concentration, emulsification time and internal to organic volume ratio (I/O) were evaluated. Results show that the lower droplet size of 0.9 µm and higher stable emulsion in terms of breakage percent of 1.12 % we

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Jun 02 2018
Journal Name
Agroforestry Systems
Biomass and buffer management practice effects on soil hydraulic properties compared to grain crops for claypan landscapes
...Show More Authors

View Publication
Scopus (21)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Thu Jan 30 2014
Journal Name
Al-kindy College Medical Journal
Relationship between Very Low Birth Weight Neonates and increased Neonatal mortality for age 0 to 7 days
...Show More Authors

B aa cc kk gg r oo uu nn dd : Very low birth weight (VLBW) neonates constitute approximately 4–7 percent of all live births and their mortality is very high. O bb j ee cc t i vv ee: to find out if there is a relationship between Very Low Birth Weight Neonates and increased neonatal mortality for age 0 to 7 days. M ee t hh oo dd ss A retrospective study of VLBW neonates admitted to NICU at Ibn Al- Baladi Pediatrics and Maternity hospital over one year (2012)were studied, study period was from April till August 2013. Exclusion criteria were: (1) neonates weighing less than 700 g and with gestational age less than 24 weeks (abortion) (2) death in the delivery room (3) neonates weighing more than 1500 g. (4) Postnatal age more than 7 days.

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 16 2025
Journal Name
Cab Reviews: Perspectives In Agriculture, Veterinary Science, Nutrition And Natural Resources
From data to decision: How wearable plant sensors help improving proactive irrigation strategies and water use efficiency
...Show More Authors

Wearable sensors are a revolutionary tool in agriculture because they collect accurate data on plant environmental conditions that affect plant growth in real-time. Moreover, this technology is crucial in increasing agricultural sustainability and productivity by improving irrigation strategies and water resource management. This review examines the role of wearable sensors in measuring plant water content, leaf and air humidity, stem flow, plant and air temperature, light, and soil moisture sensors. Wearable sensors are designed to monitor various plant physiological parameters in real-time. These data, obtained through wearable sensors, provide information on plant water use and physiology, making our agricultural choices more informed an

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Journal Of Engineering
Design narrow-band frequency amplifier (1.5GHz -1.6GHz) based on InGaP Heterojunction Bipolar Transistor (HBT) and GaAs HBT
...Show More Authors

The research aims to design a narrow-band frequency drive amplifier (1.5GHz -1.6GHz), which is used to boost the transmitter amplifier's input signal or amplify the GPS, GlONASS signals at the L1 band.

The Power Amplifier printed circuit board (PCB) prototype was designed using InGaP HBT homogeneous technology transistor and GaAs Heterojunction Bipolar Transistor (HBT) transistor. Two models have been compared; one of the models gave 16dB gain, and the other gave 23dB when using an input power signal (-15dBm). The PCB consumes 2.4W of power and has a physical dimension of 11 x 4 cm.

View Publication Preview PDF
Crossref
Publication Date
Thu May 05 2022
Journal Name
Karbala International Journal Of Modern Science
Nigella sativa Methanol Extract Inhibits PC-3 Cell Line Colonization, Induced Apoptosis, and Modulated LC3-based Autophagy
...Show More Authors

Nigella sativa has various pharmacological properties and has been used throughout history for a variety of reasons. However, there is limited data about the effects of N. sativa (NS) on human cancer cells. This study aimed at observing the roles of methanolic extract of N. sativa on apoptosis and autophagy pathway in the Human PC3 (prostate cancer) cell line. The cell viability was checked by MTT assay. Clonogenic assay was performed to demonstrate clonogenicity and Western blot was used to check caspase-3, TIGAR, p53, and LC3 protein expression. The results demonstrated that PC3 cell proliferation was inhibited, caspase-3 and p53 protein expression was induced, and LC3 protein expression was modulated. The clonogenic assay showed that PC3

... Show More
View Publication
Scopus (1)
Crossref (2)
Scopus Crossref