Background: Controversy exists concerning the presence and amount of the Bennett mandibular immediate side shift among patients and whether it is necessary to accommodate for it in adjustable articulators. The aim of this study was to register and calculate the amount of any immediate side shift (ISS) present in patients requiring full mouth rehabilitation. Materials and methods: 3- dimensional condylar movements of 50 Iraqi TMD-free patients were recorded using a stereographic fully adjustable articulator system during protrusion, left and right eccentric mandibular movements. Protrusive angles of each patient were verified to figure out the suitable fossa analog for each case. The thickness of each right and left premade fossa analog selected was measured with a vernier caliper and was tightly secured in the articulator fossa compartment. Functionally-generated path recordings were performed using custom-made intraoral clutches. Bennett ISSs, verified by the stereographic system in the molded fossae, were measured using the vernier caliper. The final right and left ISSs were estimated by subtracting the thickness of the blank fossa analog from that of the molded one. The final ISSs were recorded and statistically compared. Results: Stereographic recordings of eccentric mandibular movements revealed ISSs within all patients involved in this study. The ISSs varied among the patients and bilaterally within them. Their average values ranged between 0.80 mm for females and 1.68 mm for males, showing significant statistical differences between them but with no relevancy to age advancement. Mean values of ISSs of males' and females' mandibular left joints were more than those recorded by their right joints. Conclusion: Verifying the mandibular ISS in the molded fossae is an essential step to efficiently rehabilitate full mouth cases; thus it would be helpful to use a fully adjustable articulator system to restore complicated cases since very minor intraoral occlusal adjustments might be required for the finished restorations prior to the final cementation.
Autonomous systems are these systems which power themselves from the available ambient energies in addition to their duties. In the next few years, autonomous systems will pervade society and they will find their ways into different applications related to health, security, comfort and entertainment. Piezoelectric harvesters are possible energy converters which can be used to convert the available ambient vibration energy into electrical energy. In this contribution, an energy harvesting cantilever array with magnetic tuning including three piezoelectric bimorphs is investigated theoretically and experimentally. Other than harvester designs proposed before, this array is easy to manufacture and insensitive to manufacturi
... Show MoreIn this paper had been studied the characterization of the nanocatalyst (NiO) Mesh electrodes. For fuel cell. The catalyst is prepared and also the electrodes The structural were studied through the analysis of X-ray diffraction of the prepared nanocatalyst for determining the yielding phase and atomic force microscope to identify the roughness of prepared catalyst surface, Use has been nanocatalyst led to optimization of cell voltage, current densities & power for a fuel cell.
Littoral and benthic invertebrates from Roundwood Reservoir System were sampled. Oligochaetes and molluscs were the dominant organisms in the littoral and benthic areas Trichopterans and chironomids were the most abundant insect groups. Scuba diving samples reinforced that view. Other groups of macroinvertebrates were poorly represented. Vertical and horizontal hauls of zooplankton revealed that there were twelve species of zooplankton present. Daphnia hyalina Leydig and Bosmina coregoni Baird were the two dominant species.
Recently, the development of the field of biomedical engineering has led to a renewed interest in detection of several events. In this paper a new approach used to detect specific parameter and relations between three biomedical signals that used in clinical diagnosis. These include the phonocardiography (PCG), electrocardiography (ECG) and photoplethysmography (PPG) or sometimes it called the carotid pulse related to the position of electrode.
Comparisons between three cases (two normal cases and one abnormal case) are used to indicate the delay that may occurred due to the deficiency of the cardiac muscle or valve in an abnormal case.
The results shown that S1 and S2, first and second sound of the
... Show MoreThe main purpose of this work is the construction of an optical parametric amplifier (OPA) to generate a 629 nm pulsed laser. KTP nonlinear crystals were used for both parametric oscillation and amplification. A singly resonant parametric oscillator (OPO) is constructed to generate a signal of 1.54 μm and idler of 3.4 μm when the OPO system is pumped by 1.064 μm Q – switched Nd: YAG laser. The signal was then mixed with the pumping beam in OPA system to form the wanted wavelength. The obtained optical conversion efficiency was 60%.
In this study miconazole nitrate was formulated as topically applied emulgel; different formulas were prepared using sodium carboxymethylcellulose (SCMC) and carboxypolymethylene (carbomer 941) as gelling agents. The influence of type of gelling agent and concentration of both oil phase and emulsifying agent on drug release was studied and compared with commercially available miconazole nitrate cream (Mecozalen®). The results of in vitro release showed that SCMC emulgel bases gave better release than carbomer 941 bases and the release of drug increase from both bases as a function of increasing the concentration of emulisifying agent. The oil phase had retardation effect when
... Show MoreAbstract
Robust controller design requires a proper definition of uncertainty bounds. These uncertainty bounds are commonly selected randomly and conservatively for certain stability, without regard for controller performance. This issue becomes critically important for multivariable systems with high nonlinearities, as in Active Magnetic Bearings (AMB) System. Flexibility and advanced learning abilities of intelligent techniques make them appealing for uncertainty estimation. The aim of this paper is to describe the development of robust H2/H∞ controller for AMB based on intelligent estimation of uncertainty bounds using Adaptive Neuro Fuzzy Inference System (ANFIS). Simulatio
... Show MoreThe aesthetic contents of data visualization is one of the contemporary areas through which data scientists and designers have been able to link data to humans, and even after reaching successful attempts to model data visualization, it wasn't clear how that reveals how it contributed to choosing the aesthetic content as an input to humanize these models, so the goal of the current research is to use The analytical descriptive approach aims to identify the aesthetic contents in data visualization, which the researchers interpreted through pragmatic philosophy and Kantian philosophy, and analyze a sample of data visualization models to reveal the aesthetic entrances in them to explain how to humanize them. The two researchers reached seve
... Show MoreThe paper include study the effect thickness of the polymeric sample which is manufactured by thermo press way. The sample was used as an active tunable R6G laser media. The remarks show that, when the thickness of the samples is increased, with the same concentration, the spectrum will shift towards the short wavelength, & the quantum fluorescence yield will increased. The best result we obtained for the quantum fluorescence yield is (0.68) at the sample, with thickness (0.304mm) in Ethanol solvent, while when we used the Pure Water as a solvent, we found that the best quantum fluorescence yield is (0.63) at (0.18mm) thickness of the sample.
The paper include studies the effect of solvent of dye doped in polymeric laser sample which manufactured in primo press way, which is used as an active (R6G) tunable dye lasers. The remarks show that, when the viscosity of the solvent (from Pure Water to Ethanol), for the same concentration and thickness of the performance polymeric sample is increased, the absorption spectrum is shifts towards the long wave length (red shift), & towards short wave length (blue shift) for fluorescence spectrum, also increased the quantum fluorescence yield. The best result we obtained for the quantum fluorescence yield is (0.882) with thickness (0.25mm) in Ethanol solvent in concentration (2*10-3mole/liter), while when we used the Pure Water as a solvent,
... Show More