Preferred Language
Articles
/
jbcd-515
Sonographic evaluation of masseter muscle thickness in bruxist and non-bruxist subjects
...Show More Authors

Background: Masseter muscle is a jaw closing muscle of the mandible involved in Para functional habits; which include lip and cheek chewing, fingernail biting, and teeth clenching or bruxism which can be classified as awake or sleep bruxism. Patients with sleep bruxism are three to four times more likely to experience jaw pain and limitation of movement than people who do not experience sleep bruxism. The aim of this study is to measure the thickness of the masseter muscle in bruxist subjects and compare it with non-bruxist subjects by using sonography. Materials and Method: Forty Iraqi subjects with age ranged (20-40) divided into two groups according to the presence of bruxism. Clinical examination was made and masseter muscle thickness measured for both groups using sonography. Results: For bruxist subjects the mean thickness of masseter muscle in relaxation and clenching were (11.7 ± 1.4 mm) and (16.4 ± 1.3 mm). For non bruxist subjects were (11.2 ± 0.4 mm) and (13 ±0.3 mm) respectively. There was an extremely high statistical significant difference in masseter muscle thickness under clenching between bruxist and non bruxist subjects ( it was higher in bruxist group). Masseter muscle thickness under relaxation was significantly lower than that under clenching for both groups. Also there was a positive correlation between masseter muscle thickness and muscle function in bruxism situation. Conclusion: Masseter muscle in bruxist subject was thicker when compared to non-bruxist subject. Masseter muscle thickness was found to be positively correlated with increasing muscle function. The findings of this study indicate that the functional capacity of the masseter muscle affected by bruxism and may be considered as one of the factors influencing muscle thickness.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Feb 10 2012
Journal Name
Molecules
Design, Synthesis and Preliminary Pharmacological Evaluation of New Non-Steroidal Anti-Inflammatory Agents Having a 4-(Methylsulfonyl) Aniline Pharmacophore
...Show More Authors

A series of 4-(methylsulfonyl)aniline derivatives were synthesized in order to obtain new compounds as a potential anti-inflammatory agents with expected selectivity against COX-2 enzyme. In vivo acute anti-inflammatory activity of the final compounds 11–14 was evaluated in rat using an egg-white induced edema model of inflammation in a dose equivalent to 3 mg/Kg of diclofenac sodium. All tested compounds produced significant reduction of paw edema with respect to the effect of propylene glycol 50% v/v (control group). Moreover, the activity of compounds 11 and 14 was significantly higher than that of diclofenac sodium (at 3 mg/Kg) in the 120–300 minute time interval, while compound 12 expressed a comparable effect to that of di

... Show More
View Publication
Scopus (10)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Southwest Jiaotong University
A Recognition System for Subjects' Signature Using the Spatial Distribution of Signature Body
...Show More Authors

This investigation proposed an identification system of offline signature by utilizing rotation compensation depending on the features that were saved in the database. The proposed system contains five principle stages, they are: (1) data acquisition, (2) signature data file loading, (3) signature preprocessing, (4) feature extraction, and (5) feature matching. The feature extraction includes determination of the center point coordinates, and the angle for rotation compensation (θ), implementation of rotation compensation, determination of discriminating features and statistical condition. During this work seven essential collections of features are utilized to acquire the characteristics: (i) density (D), (ii) average (A), (iii) s

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jun 30 2009
Journal Name
Al-kindy College Medical Journal
Carotid Intima-Media Thickness in Rheumatoid Arthritis Detected by Doppler Ultrasound
...Show More Authors

Background: The excess mortality associated with
rheumatoid arthritis is largely due to
cardiovascular disease. Rheumatoid arthritis is of
primary importance in atherogenesis. The intimamedia thickness of extracranial carotid arteries is a
measurable index of the presence of
atherosclerosis.
Objective: To assess carotid intima-media
thickness in rheumatoid arthritis by Doppler
ultrasound.
Methods: Fifty two Iraqi patients with rheumatoid
arthritis were studied and compared with another
fifty two, healthy individuals matched for age and
sex as a control group. Full history was taken and
complete clinical examination was done for all
individuals in both groups. Rheumatoid arthritis
diagnosis was

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Human Sport And Exercise - 2019 - Spring Conferences Of Sports Science
The effect of continuous training on myoglobin muscle and on some specific fitness elements and basic skills of badminton players
...Show More Authors

View Publication Preview PDF
Scopus (11)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Sep 25 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Pharyngeal airway volume and its relationship to the facial morphology in nasal breathing and mouth breathing subjects (A comparative computerized tomography study)
...Show More Authors

Background: The value of lateral cephalometric radiographs to evaluate the pharyngeal airway is limited because it provided 2-dimensional (2D) images of complex 3-dimensional (3D) anatomic structures. Three dimensional analyses of the airway volumes are required to understand oral and pharyngeal adaptations in mouth breathing and nasal breathing subjects. The aim of this study was to measure the pharyngeal airway volume and the size of the face, then compare between pharyngeal airway volume in mouth breathing and nasal breathing subjects and find the gender difference in each group, also to study the relation between pharyngeal airway volume and the size of the face. Material and Methods: Fifty patients including 28 males and 22 females wit

... Show More
View Publication Preview PDF
Publication Date
Tue Jul 14 2015
Journal Name
Ibn Al-haitham J. For Pure & Appl. Sci.
Effect of Annealing Temperature and Thickness on the Structural and Optical Properties of CdSeThin Films
...Show More Authors

CdSe alloy has been prepared successfully from its high purity elements. Thin films of this alloy with different thicknesses (300,700)nm have been grown on glass substrates at room temperature under very low pressure (10-5)Torr with rate of deposition (1.7)nm/sec by thermal evaporation technique, after that these thin films have been heat treated under low pressure (10-2)Torr at (473,673)K for one hour. X-ray patterns showed that both CdSe alloy and thin films are polycrystalline and have the hexagonal structure with preferential orientation in the [100] and [002] direction respectively. The optical measurements indicated that CdSe thin films have allowed direct optical energy band gap, and it increases from (1.77- 1.84) eV and from

... Show More
Publication Date
Sat Jan 06 2018
Journal Name
American Institute Of Physics
Synthesis and characterization study of n-Bi2O3/p-Si heterojunction dependence on thickness
...Show More Authors

Abstract. In this work, Bi2O3 was deposited as a thin film of different thickness (400, 500, and 600 ±20 nm) by using thermal oxidation at 573 K with ambient oxygen of evaporated bismuth (Bi) thin films in a vacuum on glass substrate and on Si wafer to produce n-Bi2O3/p-Si heterojunction. The effect of thickness on the structural, electrical, surface and optical properties of Bi2O3 thin films was studied. XRD analysis reveals that all the as deposited Bi2O3 films show polycrystalline tetragonal structure, with preferential orientation in the (201) direction, without any change in structure due to increase of film thickness. AFM and SEM images are used to investigate the influences of film thickness on surface properties. The optical measur

... Show More
Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Aip Conference Proceedings
Synthesis and characterization study of n-Bi2O3/p-Si heterojunction dependence on thickness
...Show More Authors

View Publication
Scopus (12)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Thu Oct 01 2009
Journal Name
Saudi Med J
The frequency of 21-alpha hydroxylase enzyme deficiency and related sex hormones in Iraqi healthy male subjects versus patients with acne vulgaris
...Show More Authors

KE Sharquie, AA Noaimi, BO Saleh, ZN Anbar…, Saudi Med J, 2009 - Cited by 13

View Publication
Scopus (8)
Scopus
Publication Date
Wed Jan 30 2013
Journal Name
Al-kindy College Medical Journal
Regeneration of Pain, Touch, Cold, and Warmth, sensations in split thickness human skin grafts in adults (A clinical study)
...Show More Authors

Back ground: Skin grafting is the most common form
of reconstructive surgery, and regeneration of
sensations in skin grafts is a complex process
influenced by many factors such as , the thickness of
the graft, the depth of the grafted bed, meshing of the
graft, the condition of the bed and the surrounding
area. So many studies performed on this subject, some
of them clinically based on subjective type of sensation
tests, and others histological to detect the presence of
nerve fibers in the grafted skin
Objectives: To detect return of sensations to split
thickness skin grafts by clinical methods.
Methods: From Oct. 1995 to Oct. 2010, a clinical
prospective study performed in Al wasity Hospital for

... Show More
View Publication Preview PDF