Background: The accuracy of fitness of any dental casting is imperative for the success of any prosthodontic treatment. From the time that dental casting was first introduced, efforts have been made to produce more accurate and better fitted castings with minimal marginal discrepancy. The aim of this in vitro study was to evaluate the effects of three different investing and burnout techniques on the vertical marginal discrepancies ofceramometalcopings invested with two types of phosphate- bonded investments. Materials and methods: Sixty wax patterns were fabricated on a standardized prepared brass die representing an upper central incisor by the aid of a custom-made split mold. Three different investing and burnout techniques were applied for an Iraqi investment and a commercial type; Group I:Ring investing with conventional burnout technique (RC);Group II: Ringless investing with conventional burnout technique (RLC);Group III: Ring investing with accelerated burnout technique (RA).Twenty wax patterns of each group were divided into two subgroups according to the type of investment material used (10 for each subgroup) represented as (B) for the BellaStar XL and (W) for the WYMvest investments. Complete castings were finished and seated on the metal die. The accuracy of fit of each coping was determined by measuring the vertical marginal discrepancies between the finish line on the metal die and the margins of each coping at four specific reference points on the labial, mesial, palatal, and distal aspects of the die by the aid of a light microscope supplied with a digital camera.The arithmetic mean of each three records was computed and regarded as the amount of the marginal discrepancy of each coping and was used as a unit for the statistical analysis. Results: Mean marginal accuracy for W(RLC)was found to be the least (13.839+4.5724 um) while the highest mean value related to B(RLC) (29.033+2.102 um). In general, ANOVA test showed significant results among the mean values of the Binvestment subgroups while LSD test showed non-significance between the (RA) and both the (RC) and (RLC) subgroups. On the other hand, significance was present between the (RLC) and (RA)of the Winvestment subgroups while non-significance was located between the (RC) and both the (RLC) and (RA) subgroups. Comparing similar subgroups of the two tested investments, the Student's t-test showed non-significance between the (RC) subgroups while high significance was located between the (RLC) and (RA) subgroups respectively.Concerning the vertical marginal discrepancy of the copings, applying the (RC) technique for both investments caused non-statistical significance between the labial, mesial, palatal, and distal aspects.The (RLC) technique caused high significance between the four aspects, while the (RA) technique caused non-significance between the labial aspect only and the others. Conclusion: The Iraqi investment generally produced less vertical marginal discrepancies (using the three different investing and burn-out techniques) than the commercial investment.In order to achieve a better marginal fit, it seems that ceramometalcopings invested with the commercial investment tested are better be cast using the conventional ring investing and burnout technique.
The present study investigates the effect of the de-sanding (recycling system) on the bearing capacity of the bored piles. Full-scale models were conducted on two groups of piles, the first group was implemented without using this system, and the second group was implemented using the recycling system. All piles were tested by static load test, considering the time factor for which the piles were implemented. The test results indicated a significant and clear difference in the bearing capacity of the piles when using this system. The use of the recycling system led to a significant increase in the bearing capacity of the piles by 50% or more. Thus it was possible to reduce the pile length by (15 % or more) thus, and implementation c
... Show MoreRecent research has examined the improvement of physical and dielectric properties of BaTiO3 ceramic material by small addition of excess TiO2 or BaCO3. The prepared samples sintered at different temperatures and varying soaking time. The results show that increasing the sintering temperature within 1350°C and soaking time of 10 hrs give better electrical and physical properties, which indicate the reaction is complete at higher temperature and period.
Diabetes mellitus, or simply diabetes, is a group of metabolic diseases in which a person has high blood sugar, either because the pancreas does not produce enough insulin, or because cells do not respond to the insulin that is produced. This high blood sugar produces the classical symptoms of polyuria (frequent urination), polydipsia (increased thirst), and polyphagia (increased hunger). The aim of the study is to measure several biochemical parameters in T2DM patients and the effect of these parameters in development the disease. Laboratory investigations including Ceruloplasmin , fasting blood glucose (FBG) , malondialdehyde (MDA), serum protein, uric acid, and protein electrophoresis have been measured in patients with type
... Show MoreThe field efficacy of Actellic (organophosphate), Neporex (insect growth regulator) and
Ficam (carbamate), at the application rates of 2-4, 0.4-0.8 and 0.1-0.2 g AI/m2 respectively,
was studied against the larvae of Musca domestica L. Results of treatments involving horse
manure indicated that Actellic and Neporex produced sharp decrease of larval numbers (close
to zero) for 21d. But there was a slight recovery in larval numbers 14 d following treatment
with Ficam. The populations of predator mites were not affected due to insecticidal
applications.
In this study , Iraqi Bentonite clay was used as a filler for polyvinyl chloride polymer. Bentonite clay was prepared as a powder for some certain particle size ,followed by calcinations process at (300,700,900) OC ,then milled and sieved. The selected sizes were D ~75 µm and D ~150. After that polyvinyl Al-Cohool solution prepared and used as a coated layer covered the Bentonite powder before applied as a filler ,followed by drying , milling and sieving for limited recommend sizes. polyvinyl chloride solutions were prepared and adding of modified Bentonite power at certain quantities were followed .Sheet of these variables on the mechanical and thermal properties of the prepared reinforced particular polyvinyl chloride composite
... Show MoreEpstein-Barr Virus (EBV) infection is associated with broad spectrum of clinical manifestationsdepending on the immune status of the host, To analyze their possible role in the complication ofautoimmune hepatitis, we investigated (30) female patients with autoimmune hepatitis type-1 of(10-40)years and 25 healthy female of same ages(control groups). Both groups were carried outto measure the levels of EBV-CA IgM, IgG Ab, EBV-EA IgM, IgG Ab, and EBV-NA IgM, IgGAb using indirect immunoflourescent assay (IFAT).The prevalence of EBV-CA IgM, IgG Ab were(10%,20%) and EBV-EA IgM, IgG Ab were (10% and20%) respectively, while the prevalence ofEBV-NA IgG Ab was( 3.33%) and there are no prevalence of EBV-NA IgM Ab. There weresignificant differences (P
... Show MoreBackground: The Andrews’ six keys of normal occlusion contribute individually and collectively to the total scheme of occlusion and, therefore, are viewed as essential to successful orthodontic treatment. The present research aims to evaluate the presence of the parameters of the Andrews’ Six Keys of normal occlusion in a sample of 100 Iraqi adults with complete permanent dentition and clinically acceptable normal occlusion (Angle’s Class I) in Baghdad city. Their age range 18-25 years (60 males and 40 females). Materials and methods: Each patient was subjected to clinical examination and then study cast models were made, with their occlusal records. The measuring tools that have been used involved: Three-dimensional goniometer to me
... Show MoreIn this study, the energy charging mechanism is mathematically modeled to determine the impact of design modifications on the thermofluidic behavior of a phase change material (PCM) filled in a triplex tube containment geometry. The surface area of the middle tube, where the PCM is placed, is supported by single or multi-internal frustum tubes in vertical triplex tubes to increase the performance of the heating and cooling of the system. In addition to the ordinary straight triplex tubes, three more scenarios are considered: (1) changing the middle tube to the frustum tube, (2) changing the inner tube to the frustum tube, and (3) changing both the internal and central tubes to the frustum tubes. The impact of adopting the tube desig
... Show More