Preferred Language
Articles
/
jbcd-470
Tensile force measurement by using different lingual retainer wires, bonding materials types and thickness (A comparative in vitro study)
...Show More Authors

Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H Orthodontics composites) and two thickness of the adhesive (1mm, 2mm). The samples were prepared for each composite in which a wire was embedded; then the composite was light cured for 40 seconds and the specimens were stored in artificial saliva at 37°C in the incubator for 24 hours. The ends of the wire were drawn up and tensile force was applied through Tinius-Olsen universal testing machine until the resin failed and the results were recorded in Newton (N). Results: Statistical analysis showed that there was a highly significant difference (P ≤ 0.01) among the mean values of tensile forces of the three types of retainer wires in each thickness of composite with exception of a non significant difference (P > 0.05) between (3 braided) and (8 braided) and a non significant difference (P > 0.05) between (3 braided) and (6 coaxial) in both thickness of composite, a highly significant difference (P ≤ 0.01) between the two thickness of both composite types in each wire type and a highly significant difference (P ≤ 0.01) between the two types of composite in each wire type of both thickness of composite. Conclusion: The result of this study revealed that the 8 braided strands retainer wire shows the highest values of tensile force among the tested retainer wires, the non flowable composite demonstrates a higher tensile force than the flowable composite and increasing the thickness of composite overlying the wire increased the force required to detach the wire from the composite.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design and Testing a Neutrons and Gamma-Rays Multilayer Shield Using Different Groups of Cross – Sections
...Show More Authors

A preventing shield for neutrons and gamma rays was designed using alternate layers of water and iron with pre-fixed dimensions in order to study the possibility of attenuating both neutrons and gamma-rays. ANISN CODE was prepared and adapted for the shield calculation using radiation doses calculation: Two groups of cross-section were used for each of neutrons and gamma-rays that rely on the one – dimensional transport equation using discrete ordinate's method, and through transforming cross-section values to values that are independent on the number of groups. The memory size required for the applied code was reduced and the results obtained were in agreement with those of standard acceptable document samples of cross –section, this a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Feb 05 2019
Journal Name
Journal Of The College Of Education For Women
Measures of the British Force in Iraq and their managements to limitate the pread of Malaria among its troops (Documentary Study)
...Show More Authors

Historical scripts and Academic studies have bestrewed almost all the events of the movement of march 1941 . Yet the need was present to shine more light on important sides . These important sides were neglected due to some reasons among which came the absence of the historical material which can make a new historical detection. Then there were historical topics concerning our research which comes within context of sanitarily conditions , rarely seizes the attention of the researchers for many reasons some of them were not subjective.
The spread of Malaria among the British force was one of the sanitarily conditions that were related to the movement of march since their arrival to Basra city and its continuous spread after the second

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 04 2016
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Study in the procedural provisions of the action consumption incidents A comparative study Under Iraqi Consumer Protection Act No. 1 of 2010.: Study in the procedural provisions of the action consumption incidents A comparative study Under Iraqi Consumer Protection Act No. 1 of 2010.
...Show More Authors

This research Sheds highlights the procedural protections that must be enjoyed by the consumer in the face of the product, which is the protection of no less dangerous than the substantive protection of our obligations and duties delivered by the legislature upon the product of consumer interest, what is the benefit of the right if the access road to him complicated, so know The consumer has a right to the face of the product, but leaves the claim, either to ignorance For access to this right either to the difficulty of connecting to him.
That this research modest attempt we tried through which to focus on the way to the consumer behavior of arrived right, as we tried to highlight the weaknesses and the complexity of the procedure to

... Show More
View Publication
Publication Date
Wed Sep 09 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Regulation of HbA1c of uncontrolled diabetic type II obese and normal weight patients by oral hygiene performance (Comparative study)
...Show More Authors

Background: The association between periodontal diseases incidence and development and the metabolic diseases as Diabetes Mellitus and Obesity are recently have attract great deal of researchers attention and investigation. The periodontal health proved to reduce the systemic inflammatory reactions and positively improve the glycemic control of diabetes Type2 patients. The aim of the study was to investigate the influence of oral hygiene control on the glycemic control of obese and normal weight moderately controlled Diabetic Type 2 patients, in addition to study the association of obesity with the gingival inflammation. Materials and Methods: Cross sectional study of three months duration. Included 30 moderately controlled diabetic type2 p

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
The push out bond strength of bioceramic seal-er(Total Fill) after warm and cold obturation tech-niques An in vitro comparative
...Show More Authors

Background: The goal of a root canal treatment is three dimensional obturation with a complete seal of the root canal system. The aim of this study was to evaluate and compare the effect of two warm obturation techniques, warm vertical compaction (WVC) and, carrier based obturation technique Gutta Core (GC), versus two cold obturation techniques, cold lateral compaction (CLC) and, single cone (SC) on push-out bond strength of bioceramic sealer (Total Fill) at three different root levels. Materials and Methods: Forty extracted maxillary first molars teeth with a straight round palatal root canal and mature apices were selected for this study. After sectioning the palatal roots to 11 mm from the root apex, the canals were prepared wit

... Show More
Preview PDF
Crossref (5)
Crossref
Publication Date
Thu Sep 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
The push out bond strength of bioceramic seal-er(Total Fill) after warm and cold obturation tech-niques An in vitro comparative
...Show More Authors

Background: The goal of a root canal treatment is three dimensional obturation with a complete seal of the root canal system. The aim of this study was to evaluate and compare the effect of two warm obturation techniques, warm vertical compaction (WVC) and, carrier based obturation technique Gutta Core (GC), versus two cold obturation techniques, cold lateral compaction (CLC) and, single cone (SC) on push-out bond strength of bioceramic sealer (Total Fill) at three different root levels. Materials and Methods: Forty extracted maxillary first molars teeth with a straight round palatal root canal and mature apices were selected for this study. After sectioning the palatal roots to 11 mm from the root apex, the canals were

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Sensitivity of Streptococcus mutans to Selected Nanoparticles (in Vitro Study)
...Show More Authors

Background: Nanoparticles are clusters of atoms in a size range from (1-100) nm. Nano dentistry creates amazing useful structures from individual atoms or molecules (nanoparticles), which provides a new alternative and a possibly superior strategy in prevention and treatment of dental caries through management of dental plaque biofilms. The aim of the study was to test the sensitivity of Streptococcus mutans to different concentrations of hydroxyapatite and iron oxide nanoparticles suspension solutions, in comparison to chlorhexidine, and de-ionized water, in vitro. Materials and methods: Agar well technique was applied to test the sensitivity of Streptococcus mutans to different concentrations of hydroxyapatite and iron oxide nanoparticle

... Show More
View Publication
Crossref (9)
Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Bacterial Contamination of Acrylic Resin Complete Denture : In Vitro Study
...Show More Authors

Background: Cross contamination of dental appliances in the dental clinics and laboratories may potentially be a health hazard to the dental team and the patient. This study aimed to evaluate bacterial contamination of acrylic complete denture as received from dental laboratory before delivery to the patient, and then to evaluate the effectiveness of disinfection with 2% chlorhexidine and Kin denture cleaner tablet. Materials and methods: 45 newly made upper complete dentures undergone biaacterial examination for contamination before delivered to the patient. Samples were examined in two stages, first after finishing and polishing; when collected from the laboratory and before inserting to the patient mouth, second; after the samples were

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Photoacoustic Imaging for Tumor Detection: An in vitro Simulation Study
...Show More Authors

Photoacoustic is a unique imaging method that combines the absorption contrast of light or radio frequency waves with ultrasound resolution. When the deposition of this energy is sufficiently short, a thermo-elastic expansion takes place whereby acoustic waves are generated. These waves can be recorded and stored to construct an image. This work presents experimental procedure of laser photoacoustic two dimensional imaging to detect tumor embedded within normal tissue. The experimental work is accomplished using phantoms that are sandwiched from fish heart or blood sac (simulating a tumor) 1-14mm mean diameter embedded within chicken breast to simulate a real tissue. Nd: YAG laser of 1.064μm and 532nm wavelengths, 10ns pulse duration, 4

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 09 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Radiopacity of modified microhybrid composite resin:(An in vitro study)
...Show More Authors

Background: The aim of this study was to measure the radiopacity (RO) of modified microhybrid composite resins by adding 2 types of nanofillers (Zinc Oxide and Calcium Carbonate) in two concentrations 3% and 5% and comparing them to unmodified microhybrid composite resins and to nanofilled composite resin. Materials and Methods: Two types of composite resin were used (Microhybrid composite MH Quadrent anterior shine and Nanofilled composite resin Filtek Z350 XT), for each tested group five disk-shaped specimens (1-mm-thick and 15 mm diameter) were fabricated. The material samples were radiographed together with the aluminum step wedge. The density of the specimens was determined with a transmission densitometer and was expressed in term of

... Show More
View Publication Preview PDF