Background: Since the periodontal disease Index of Ramfjord (Ramfjord index) can potentially shorten the examination time by almost half, many studies evaluated Ramfjord teeth in predicting full-mouth periodontal status of an adult population. The aim of this study was to evaluate the benefit of Ramfjord teeth in predicting the full-mouth clinical attachment level of an adult population in patients attending the college of dentistry- Baghdad University. Materials and methods: The study participants were 100 patients with age range from 30-60 years old which represent group zero. The patients were divided into three main groups according to the age of the patients. Group I and group II each of them composed of 30 patients while group III composed of 40 patients. In the first time clinical attachment level (CAL) was measured from the full mouth (FM) and then from the Ramfjord teeth (RT) (teeth number: 16, 21, 24, 36, 41, 44) in all groups. Clinical attachment level (CAL) was measured in millimeters using periodontal probe. Results: The difference in the mean clinical attachment level measured from the full mouth (FM) and Ramfjord teeth (RT) by using paired t - test was non significant in all the groups. Also in all groups the correlation coefficient as well as beta coefficient was high. Conclusion: The high agreement between Ramfjord teeth and full mouth CAL confirm the epidemiological validity of Ramfjord teeth to represent the full mouth.
The -multiple mixing ratios of γ-transitions from levels of populated in the are calculated in the present work by using the a2-ratio methods. We used the experimental coefficient (a2) for two γ-transitions from the same initial state, the statistical tensor, which is related to the a2-coefficient would be the same for the two transitions. This method was used in a previous work for pure transitions or which can be considered pure. In these cases the multiple mixing ratios for the second transition ( ) equal zero, but in our work we applied this method for mixed γ-transitions and then the multiple mixing ratio ( ) is known for one transition. Then we calculate the ( ) value and versareversa. The weight average of the -values calcu
... Show MorePiroxicam (PIR) is a nonsteroidal anti-inflammatory drug of oxicam category, used in gout, arthritis, as well as other inflammatory conditions (topically and orally). PIR is practically insoluble in water, therefore the aim is prepare and evaluate piroxicam as liquid self-nanoemulsifying drug delivery system to enhance its dispersibility and stability. The Dispersibilty and Stability study have been conducted in Oil, Surfactant and Co-surfactant for choosing the best materials to dissolve piroxicam. The pseudo ternary phase diagrams have been set at 1:1, 2:1, 3:1 as well as 4:1 ratio of surfactants and co-surfactants, also there are 4 formulations were prepared by using various concentrations of transcutol HP, cremophore EL and triacetin
... Show MoreThis study was carried out to evaluate the antioxidant activity of Iraqi sumac seeds (Rhus coriaria. L) (Anacardiaceae). Total phenolic compounds and flavoniods were determined in three different sumac seed extracts (SSE) (aqueous,ethanolic and methanolic extract). For extraction Antioxidant activity of SSE were evaluated by various antioxidant assays, including total antioxidant capacity, reducing power,by using 1,1-diphenyl-2-picryl hydrazyl (DPPH) radical scavenging, nitric oxide scavenging, Hydroxyl radical scavenging, and metal ion chelating activities. These various antioxidant activities were compared with ascorbic acid as a standard antioxidant.The results showed that the three(SSE), contained large amounts of phenolic and flavonio
... Show MoreFunctionalized-multi wall carbon nanotubes (F-MWCNTs) and functionalized-single wall carbon nanotubes (F-SWCNTs) were well enhanced using CoO Nanoparticles. The sensor device consisted of a film of sensitive material (F-MWCNTs/CoONPs) and (F-SWCNTs/CoO NPs) deposited by drop- casting on an n-type porous silicon substrate. The two sensors perform high sensitivity to NO2 gas at room temperatures. The analysis indicated that the (F-MWCNTs/CoONPs) have a better performance than (F-SWCNTs/CoONPs). The F-SWCNTs/CoONPs gas sensor shows high sensitivity (19.1 %) at RT with response time 17 sec, while F-MWCNTs/CoONPs gas sensor show better sensitivity (39 %) at RT with response time 13 sec. The device shows a very reproducible sensor p
... Show More