Background: Dental implants are a suitable option for the replacement of some or all missing teeth. The successful insertion of a biocompatible material into living tissue with little to no evidence of rejection has revolutionized medicine and dentistry. An increase in bone response was observed with local administration of growth hormone around dental implants. Growth hormone may act as a bone stimulant in the placement of endosseous dental implants and enhances osseointegration. The aim of the study was to evaluate immunohistochemically the effect of the topical application of growth hormone on the osseointegration of cpTi implant. Materials and Methods: Eighty titanium screw implants were inserted in the tibia of the forty adult rabbits. Growth hormone was applied on experimental implants. Immunohistochemical tests were performed on the implants of both control and experimental groups for (3 days1, 2, and 6 weeks) healing intervals. Results: Titanium implants coated with growth hormone revealed an early bone formation, minerlization and maturation in comparison to control. Immunohistochemical findings revealed positive expression for VEGF in experimental implant in comparison to control one. Conclusion: Topical application of growth hormone may act as a bone stimulant in the placement of endosseous dental implants and enhances osseointegration.
The researcher used the experimental approach due to its suitability and the nature of the research problem. The research community was represented by the eighth-grade students in the Rozak Elementary Mixed School affiliated with the General Directorate of Education in Erbil / the center, for the academic year (2021-2022), the number is (96) students, and the research sample consisted of (63) male and female students, with (31) in the experimental group, and (32) in the control group, and (11) students were excluded by (5) students from the experimental group, and (6) students from the control group, as the excluded, are students who failed and were absent from the lessons, and accordingly, the research sample became composed of (52) mal
... Show MoreThe change in the size of the droplets during the pesticide application process could have a negative impact on the percentage of drift or the losses of pesticides to the environment. One of the factors that could affect the droplet size produced from a single nozzle is the internal design of the nozzle itself, in addition to the wear of the nozzle orifice as a result of the usage time. In this research, three types of nozzles with different internal designs were used (Turbo TeeJet (TT), Turbo TwinJet (TTj 6011003), and Drift Guard (DG 11003)). The nozzles were subjected to an accelerated wear test for one hundred hours, and different droplet size parameters (Dv 0.1, Dv 0.5, Dv 0.9),
Drilling solutions can be considered as an intricate mixture comprising of number of chemical additives which aid specific needs such as controlling the rheological properties and reducing corrosion. Inhibitors are substances that are added in small concentrations to corrosive environment to decrease the corrosion. Their applications can be found in drilling equipments. The effect of adding Zinc Sulphate and Carboxymethyl Cellulose to study their influence on the corrosion of carbon steel in Bentonite mud has been evaluated using Weight Loss Technique. This study focuses on determining rheological properties and corrosion characteristics. Results show CMC and ZnSO4 work as inhibitors when added to the Bentonite with inhibition
... Show MoreThe present study is considered the first on this sector of the Tigris River after 2003. It is designed for two aims, the first is to demonstrate the seasonal variations in physicochemical parameters of Tharthar-Tigris Canal and Tigris River; the second is to explain the possible effects of canal on some environmental properties in the Tigris River. Water samples were being collected monthly. Six sampling sites were selected, two on Tharthar Canal and four along the Tigris River, one before the confluence as a control site and the others downstream the confluence with the canal. For a period from January to December 2020, nineteen physicochemical parameters were investigated including air and water temperature, turbidity, electrical cond
... Show MoreThis study investigates consecutive reaction assisted by pervaporation for the first time. It studies the saponification of diethyladipate DA with sodium hydroxide NaOH solution synchronous with separating ethanol from the reaction mixture through an aqueous – organic membrane. The effect of time on some variables such as: permeated ethanol concentration EtOH wt%, separation factor (α), concentration of NaOH solution CB in the reaction medium and the conversion of DA to monoethyladipate (the intermediate product) was studied. It was shown that EtOH wt% and the conversion increased with increasing time unlike CB but (α) showed the existence of maximum value during the time of experiment. The process of reaction assisted by pervaporation
... Show MoreIt is no secret that the prophets speech is of great importance, as the second source of Islamic legislation after the Holy Quran, and as such we must reserve and verify the authenticity of the novel and the narrators seizure, and all the conditions laid down by the scholars.
The subject of our research here concerns part of this verification, which is the unknown, the subject of the unknown hadith is considered a matter of great interest by the modernists because it relates to the validity of the novel and the narrators, and the methods of the modernists varied in terms of the reasons for this weakness, the fool never entertained them by the reckless narrative.
I chose the subject of my research the types of Mahjail and
... Show MoreBackground: The primary stability of the dental implant is a crucial factor determining the ability to initiate temporary implant-supported prosthesis and for subsequent successful osseointegration, especially in the maxillary non-molar sites. This study assessed the reliability of the insertion torque of dental implants by relating it to the implant stability quotient values measured by the Osstell device. Material and methods: This study included healthy, non-smoker patients with no history of diabetes or other metabolic, or debilitating diseases that may affect bone healing, having non-restorable fractured teeth and retained roots in the maxillary non-molar sites. Primary dental implant stability was evaluated using a torque ratc
... Show More