Background: Osteoporosis affects almost all of the bones in the female body; the most important one in the facial bone is mandible. Menopause is defined as an absence of the menses for one year. During this time, estrongen, progesterone and ovarian androgens production are diminished due to adult onset ovarian failure which leads to osteoporosis. This study aimed to evaluate the use of computed tomography mandibular morphometric indices for the assessment of pre and postmenopausal osteoporotic women. Subjects and material: This study conducted on 50 Iraqi females divided into 2 groups 20 -30years old as a control group and over50 years old as a study group attending Al-Karkh hospital, Department of Computed Tomography.(each group25 female). Information from each female was recorded and mentioned on a case sheet specially prepared. Data collected, when analysed, using SPSS version 13 program loaded on a computer machine. Results: All the measurements in this study( gonial angle in degree, antigonial angle in degree and depth in millimetre, mandibular and mental thickness in millimetre, bone mineral density in HU and mandibular cortex index),there were no statically significant differences between right and left side P-value <0.001. Gonial angle had statistically positive linear correlation with age in the study group P-value <0.001. Bone mineral density and mandibular and mental thickness had statically negative linear correlation with age. Antigonial angle increased as age increased till reach 180 degree in some cases and the depth decreased correlated to the age till reach zero mm in some cases P-value <0.001. Mandibular cortex index increased in bone irregularity related to increase in age. Conclusion: It was concluded that osteoporosis and osteoporosis risk in postmenopausal females could be detected by using CT scan through measuring certain mandibular radiomorphometric indices.
This paper presents a comparison study on thermal performance conic cut twist tape inserts in laminar flow of nanofluids through a constant heat fluxed tube. Three tape configurations, namely, quadrant cut twisted tape (QCT), parabolic half cut twisted tape (PCT), and triangular cut twisted (VCT) of twist ratio= 2.93 and cut depth= 0.5 cm were used with 1% and 2% volume concentration of SiO2/water and TiO
... Show MoreA new, simple and sensitive method was used forevaluation of propranolol withphosphotungstic acidto prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between propranolol and phosphotungstic acid in an aqueous medium to obtain a yellow precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.007-13 mmol/L for cell A and 5-15 mmol/L for cell B, and LOD 207.4792 ng/160 µL and 1.2449 µg/160 µL respectively to cell A and cell B with correlation coefficient (r) 0.9988 for cell A, 0.9996 for cell B, RSD% was lower than 1%, (n=8) for the
... Show MoreEstimation of the unknown parameters in 2-D sinusoidal signal model can be considered as important and difficult problem. Due to the difficulty to find estimate of all the parameters of this type of models at the same time, we propose sequential non-liner least squares method and sequential robust M method after their development through the use of sequential approach in the estimate suggested by Prasad et al to estimate unknown frequencies and amplitudes for the 2-D sinusoidal compounds but depending on Downhill Simplex Algorithm in solving non-linear equations for the purpose of obtaining non-linear parameters estimation which represents frequencies and then use of least squares formula to estimate
... Show MoreTraumatic radial nerve injury in humeral shaft fracture is the most common traumatic nerve injury in long-bone fracture, with overall prevalence 2-18%, ranging from traction to complete transection. Spontaneous recovery may reach 88%. The aim of the study is to assess the sensitivity & specificity of the ultrasound to detect the radial nerve injury and to see if this can be used as a diagnostic test. This is a prospective study on 17 adult patients with a closed fracture of the humeral shaft, dividing into two groups, the first group of 7 patients had signs and symptoms of radial nerve palsy at presentation and the second group of 10 patients had intact radial nerve function was considered as a control group. All these patients had at leas
... Show MoreRuthenium-Ruthenium and Ruthenium–ligand interactions in the triruthenium "[Ru3(μ-H)(μ3-κ2-Hamphox-N,N)(CO)9]" cluster are studied at DFT level of theory. The topological indices are evaluated in term of QTAIM (quantum theory of atoms in molecule). The computed topological parameters are in agreement with related transition metal complexes documented in the research papers. The QTAIM analysis of the bridged core part, i.e., Ru3H, analysis shows that there is no bond path and bond critical point (chemical bonding) between Ru(2) and Ru(3). Nevertheless, a non-negligible delocalization index for this non-bonding interaction is calculated
... Show MoreDensity Functional Theory (DFT) method of the type (B3LYP) and a Gaussian basis set (6-311G) were applied for calculating the vibration frequencies and absorption intensities for normal coordinates (3N-6) at the equilibrium geometry of the Di and Tetra-rings layer (6, 0) zigzag single wall carbon nanotubes (SWCNTs) by using Gaussian-09 program. Both were found to have the same symmetry of D6d point group with C--C bond alternation in all tube rings (for axial bonds, which are the vertical C--Ca bonds in rings layer and for circumferential bonds C—Cc in the outer and mid rings bonds). Assignments of the modes of vibration IR active and inactive vibration frequ
... Show MoreThe preparation and characterization of innovative nanocomposites based on zinc oxide nanorods (ZNR) encapsulated by graphene (Gr) nanosheets and decorated with silver (Ag), and cupper (Cu) nanoparticles (NP) were studied. The prepared nanocomposites (ZNR@Gr/Cu-Ag) were examined by different techniques including Field Emission Scanning Electron Microscope (FESEM), Transmission electron microscopy (TEM), Atomic force microscopy (AFM), UV-Vis spectrophotometer and fluorescence spectroscopy. The results showed that the ZNR has been good cover by five layers of graphene and decorated with Ag and Cu NPs with particles size of about 10-15 nm. The ZNR@Gr/Cu-Ag nanocomposites exhibit high absorption behavior in ultraviolet (UV) region of sp
... Show Morerhabditid Mesorhabditis franseni Fuchs, 1933 (Family, Mesorhabditidae) and pratylenchid nematode Pratylenchus goodeyi Sher and Allen, 1953 (Family, Pratylenchidae). They were illustrated by molecular aspects. All specimens of both genera were cultured and reproduced for DNA extraction. M. franseni (IRQ.ZAh2 PP528819.1 isolate) was characterized. P. goodeyi (IRQ.ZAh5 PP535537 isolate) was also characterized. Selected specimens of these two species were molecularly characterized using the partial ITS-rRNA gene sequences. The ITS-rRNA sequence of IRQ.ZAh2 PP528819.1 isolate had a range of (98.62%-100%) sequence homology with ITS-rRNA sequence of M. franseni available in NCBI database. While, the ITS-rRNA sequence of IRQ.ZAh5 PP535537 isolate h
... Show More