Background: In this study we evaluate the effect of plasma treatment (oxygen and argon) gas in two different exposure times on the surface of heat cure and light cure acrylic resin. Materials and method: 100 specimens of heat cure and light cure acrylic resin were fabricated. The measurements of the samples were (75mm, 25mm and 4.5mm) length, width and depth respectively with stopper of 3mm depth. Two types of gas used oxygen and argon in (5,10) min by using (DC-glow discharge plasma device) then we apply cold cure soft lining material, with the help of Instron machine we test the shear stress value. Results: A highly significant effect after argon and oxygen gases treatment in both 5 and 10 min exposure times on shear bond strength to soft liner in heat cure denture base material. Conclusion: In this study we found that the exposure of heat cure acrylic resin to plasma gases (argon and oxygen) increase the shear bond strength (SBS) values significantly.
Diamond-like carbon, amorphous hydrogenated films forms of carbon, were pretreated from cyclohexane (C6H12) liquid using plasma jet which operates with alternating voltage 7.5kv and frequency 28kHz. The plasma Separates molecules of cyclohexane and Transform it into carbon nanoparticles. The effect of argon flow rate (0.5, 1 and 1.5 L/min) on the optical and chemical bonding properties of the films were investigated. These films were characterized by UV-Visible spectrophotometer, X-ray diffractometer (XRD) Raman spectroscopy and scanning electron microscopy (SEM). The main absorption appears around 296, 299 and 309nm at the three flow rate of argon gas. The value of the optical energy gap is 3.37, 3.55 and 3.68 eV at a different flow rate o
... Show MoreBackground: This study aimed to examine the efficacy of methylene blue (MB) and toluidine blue O (TBO) photodynamic therapy (PDT) as adjuncts to root surface debridement (RSD). Methods: This split-mouth, randomized, controlled clinical trial included eighteen patients, and a total of 332 sites (control = 102, MB = 124 and TBO = 106) were examined. Two sessions of PDT were completed at baseline and two weeks after RSD. Clinical parameters of bleeding on probing (BOP), plaque index (PI), probing pocket depth (PPD), and clinical attachment level (CAL) were measured pre- and post-treatment. Results: PPD and BOP reductions in sites treated by RSD with adjunctive photosensitizers (MB and TBO) were significantly higher than in control site
... Show MoreLight naphtha treatment was achieved over 0.3wt%Pt loaded-alumina, HY-zeolite and Zr/W/HY-zeolite catalysts at temperature rang of 240-370°C, hydrogen to hydrocarbon mole ratio of 1-4 0.75-3 wt/wt/hr, liquid hourly space velocity (LHSV) and at atmospheric pressure. The hydroconversion of light naphtha over Pt loaded catalyst shows two main reactions; hydrocracking and hydroisomerization reactions. The catalytic conversion of a light naphtha is greatly influenced by reaction temperature, LHSV, and catalyst function. Naphtha transformation (hyroisomerization, cracking and aromatization) increases with decreasing LHSV and increasing temperature except hydroisomerization activity increases with increasing of temperature till 300°C then began
... Show MoreThe present study was set to investigate the potential association between the level of Interleukin-6 (IL-6), as a key component of the pro-inflammatory response, with different thalassemia’s biological and clinical features. For this purpose, one hundred fifty blood samples were collected from 100 beta-thalassemia patients, who attended the Genetic Hematology Centre at Ibn Al- Baladi Hospital in Baghdad, Iraq, and 50 healthy subjects who were employed as a control group. IL-6 levels were estimated using an ELISA Kit, whereas other thalassemia-related clinical features (such as HbA, HbF, ferritin, blood transfusions, splenectomy status, and the history of frequent infection) were additionally assessed. The results of the present s
... Show MoreThis study revealed the efficiency of Bacillus subtilisin degrading two textile dyes (disperse red and disperse yellow), the rates of red dye removal when measured after 24, 48, 72 and 96 hours for the concentrations of 50 ppm were 51.67, 67.56, 84.67 and 95.33%, for the concentration 150 ppm were 41.67, 62.67, 80.67 and 89.67%, while for the concentration 300 ppm were 25.67, 42.67, 71.67 and 84.33%. The results of yellow dye removal showed that the concentration of 50 ppm were 49.67, 65.33, 83.33 and 92.67%, for the concentration of 150 ppm were 38.33, 60.33, 77.33 and 87.33%, and for the concentration, 300 ppm were 24, 36.67, 68.33 and 81.67%, when measured after 24, 48, 72 and 96 hours. Results recorded a slight decrease in pH valu
... Show MoreThe dynamics of a single condensing two-phase bubble of two different dispersed-continuous systems were studied. The systems were, CCl4 - water and CCl4 - 100% glycerol. Cinephotography was used to determine the change in height, diameter and time. These results were used to determine the experimental rise velocity of the bubble, which was compared with a theoretical one based on some equations used. It was found that the velocity of the first system remained almost constant, while it decreased gradually for the second system.
Examination of 241 specimens of two bee-eater species, Merops apiaster and Merops
superciliosus persicus reveal recording of Haemoproteus meropis (Zagar, 1945) emend.
Bennett, 1978 and H. manwelli Bennett, 1978 for the first time in Iraq. A new species
Haemoproteus hudaidensis sp. nov. is described. Microfilariae are also infected the two host
species. The results are discussed with the pertinent literature and the necessary comparision
of morphometric measurements of the recorded parasites with that previously reported is
provided along with a taxonomic key including the newly described haemoproteid.
This study, establishes two stochastic monotonicity results concerning the run length of an upper one –sided Exponentially Weighted Moving Average (EWMA) control charts, based on the logarithm of the sample variance, for monitoring a process standard deviation, these properties cast interesting light on the control chart performance, and their extension to other one –sided EWMA control charts.