Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Materials and methods: Eight models were constructed including four designs of anchorage system (ball-cup, ball-O Ring, bar without distal extension and bar with distal extension).The first group of models were supported by four dental implant and second group of models were supported by two dental implant only. Models constructed from the data obtained directly from patient The contour of bone was obtained from C.T scan image of patient, then data transferred to ANSYS program for modeling then load applied and solve the equation by the program, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD.. After load application, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD . Results: In the present study the stress distribution and maximum stresses value around dental implant had a relationship to the number of dental implant. , The result appeared that the maximum stresses and means of stresses value was lower in the first group of models (which was supported through the use four dental implant) than the second group of models (which was supported through the use of two dental implant only). For the first group of models the maximum stresses value around mesial implant was11.67, 10.51, 10.98 and 10.72 Mpa, while the maximum stresses around distal implant was 21.33, 18.51, 18.86, and17.56 Mpa for models 1,2,3 and 4respectively ,and the stresses around implant supporting second group of models was 22.52, 22.16, 20.51 and 19.60 Mpa for models 5,6,7and8 respectively .Statistical analyses of means value appeared that there was statistically significant difference in stresses means value around implant of the second group with that’s values around mesial and distal implant supporting first group of model . Regarding the result of both ball and bar system, it has been demonstrated that stress was greater with ball attachment and MIR-OD supported by the use of four dental implants and anchored by bar attachments with distal extension gives the minimum values of stresses than the rest models. Also the results show that higher stresses value was appeared at the cortical bone ring surrounding dental implant especially the distal implant nearest to the free end extension area. Also it was appeared that the best model was Mandible implant- retained overdenture that’s anchored by bar with distal extension and support by four dental implant. Conclusions: Bar-clips with distal extension mode of attachment considered the best type in producing the least stresses around dental implant regardless number of dental implant used.
The duration of the contract is a legal term first provided for in French Amendment Decree No. 131/2016, and given the increasing importance of time in contracts, we have chosen to study the legal rules governing time at the formative stage by drawing on changes in French law compared to both Iraqi and Egyptian laws. Article 1102 of French Amendment Decree No. 131/2016 stipulates that: "Everyone is free to contract or not to contract, to choose the person with whom he contracts, and to determine the content and form of the contract within the limits established by law." Contractual freedom does not permit a breach of the rules relating to public order), as well as article 1104, which provides for (contracts must be nego
... Show MoreUniversity Campuses, as any lively physical entity, is subject to continuous variation due to . growth, development and change. This reality covers the existing or futuristic additives or additions, consecutively these changes may have a strong sensation of disorientation as a result of formatic changes in buildings, or in movement paths. And it epitomized the research problem to "the need for knowledge to clarify the impact of intellectual and executive policy in achieving coherence, functional and space organization of the elements of the university urban environment and in the stages of future growth and change," the search targeted "to highlight the study of constraction politics on campus Bmqomad
... Show MoreInthis investigation the epoxy was reinforced by orange peel and carbonized orange peel particles with percentages (5%, 10%, 15% and 20% by weight).Mechanical tests like:Tensile, flexural,Hardness, impact and compression were carried out on these natural epoxy composites. The results showed the tensile strength have a higher value by adding (15% by weight )of orange peel and carbonized orange peel particles to epoxy,while the value (10% by weight ) of addition is suitable to get improvement in the other mechanical properties as flexural strength, Hardness, impact and compressive strength. The epoxy / carbonized orange peel powder have the best valuesin all mechanical properties than t
Breast tumors patients generally have more oxidative stress than normal females. This was clear from a highly significant elevation (P<0.05) in malondialdehyde level in RBCs, serum and tissue of all patients groups with breast cancer as compared with control group. In this study we had found that free radicals in malignant breast tumors were higher than benign tumors, therefore the MDA might be used as a marker for prognosis of the disease.
In this research we have been studied the 3rd order spherical aberration for an optical system consisted of obscured circular aperture with non central circular obscuration through the calculation of point spread function (P.S.F) in presence of the obscuration in the center and comparing the obtained results with that results of moving obscuration far away from the center, where the results showed significant improvement for(P.S.F) value. The study was done of different obscurities ratios in addition to the different 3rd order spherical aberration values (W40=0.25 ,0.5 ,0.75 ,1 ).
DBNRSK Sayed, Journal of Strategic Research in Social Science (JoSReSS), 2020
Experiments were conducted to study the behavior of the solid particles (proppant) inside the hydraulic fracture during the formation stimulation, and study the effect of the proppant concentration on the hydraulic fracturing process, which lead to bridge and screen-out conditions inside the fractures across the fracture width that restricts fracturing fluid to flow into the hydraulic fracture. The research also studies the effect of the ratio between the fracture size and the average particles diameter “proppant", on fracture bridging. In this study two ratios were considered β= 2 and 3 ,where β=Dt / Dp where: Dt= hydraulic fracture size (width) and Dp=Average particles diameter.
This work pr
... Show More
