Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Materials and methods: Eight models were constructed including four designs of anchorage system (ball-cup, ball-O Ring, bar without distal extension and bar with distal extension).The first group of models were supported by four dental implant and second group of models were supported by two dental implant only. Models constructed from the data obtained directly from patient The contour of bone was obtained from C.T scan image of patient, then data transferred to ANSYS program for modeling then load applied and solve the equation by the program, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD.. After load application, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD . Results: In the present study the stress distribution and maximum stresses value around dental implant had a relationship to the number of dental implant. , The result appeared that the maximum stresses and means of stresses value was lower in the first group of models (which was supported through the use four dental implant) than the second group of models (which was supported through the use of two dental implant only). For the first group of models the maximum stresses value around mesial implant was11.67, 10.51, 10.98 and 10.72 Mpa, while the maximum stresses around distal implant was 21.33, 18.51, 18.86, and17.56 Mpa for models 1,2,3 and 4respectively ,and the stresses around implant supporting second group of models was 22.52, 22.16, 20.51 and 19.60 Mpa for models 5,6,7and8 respectively .Statistical analyses of means value appeared that there was statistically significant difference in stresses means value around implant of the second group with that’s values around mesial and distal implant supporting first group of model . Regarding the result of both ball and bar system, it has been demonstrated that stress was greater with ball attachment and MIR-OD supported by the use of four dental implants and anchored by bar attachments with distal extension gives the minimum values of stresses than the rest models. Also the results show that higher stresses value was appeared at the cortical bone ring surrounding dental implant especially the distal implant nearest to the free end extension area. Also it was appeared that the best model was Mandible implant- retained overdenture that’s anchored by bar with distal extension and support by four dental implant. Conclusions: Bar-clips with distal extension mode of attachment considered the best type in producing the least stresses around dental implant regardless number of dental implant used.
Background: The development of orthodontic biomaterials that attract less biofilm has been a goal for decades. Adhesion and colonization of cariogenic streptococci are considered to play key roles in the development of enamel demineralization related to orthodontic materials. The aim of this study was to quantitatively evaluate the Mutans streptococci adhesion to coated orthodontic archwires (Epoxy and Teflon) and uncoated archwires (stainless steel and nickel-titanium) with respect to incubation time in the presence and absence of saliva. Material and Method: Six types of archwires stainless steel and nickel titanium with two type of coating (Epoxy, Teflon) were used in this study. Twelve specimens of each archwire were incubated in steri
... Show MoreBackground :Infectious disorders in general have high morbidity and mortality.. CNS infections include many disorders like bacterial meningitis, tuberculous and other subacute and chronic meningitis, viral meningitis, cerebral abscess, spinal cord infections, and others.
Objective: To assess our locality about prevalence of CNS infections , to have more awareness regarding CNS infections, and to try to find the proper way to reduce their prevalence and to treat them in appropriate way.
Method :We revised the records of all the cases of CNS infections excluding cases of spinal cord infections who were admitted in the wards of neuroscience hospital over the previous two years ( from July/2010 to June 2012 ),those were 132 cases.Seaso
S Khalifa E, AR Jamal R, N Adil A, J Munqithe M…, 2009
The present study attempts to examine verbal/nonverbal impoliteness in the classroom interaction and outside it in one of the movies, namely, The Marva Collins. Impoliteness, which is significantly studied within pragmatics, is a negative attitude towards particular behaviors. It always presumes to have emotional concerns for at least one participant who has caused it. This study is an attempt to examine verbal/nonverbal impoliteness in The Marva Collins movie. The study aims to investigate the different types of impoliteness strategies used in the four selected scenes and find out whether the speaker’s status has anything to do with the types of impoliteness. Besides, the functions performed are also examined by following a qual
... Show MoreThis research is a new reading of some of the words in the Holy Quran, which is very old. It is a human reading in which religions are intertwined by recognizing the relationship between man and his fellow man in the unity of existence and the unity of the source of religions and the unity of language. The importance of this research in comparing some of the Arabic words has been contained among books believed by followers that it is from the one God Sunday.
When words are spoken in one way in the form of one creature, from the beginning of creation to the present day, this indicates the single origin of the languages..
The research tools were books of heavenly religions, the Quran, dictionaries and interpretations.
... Show MoreThermomechanical analysis (TMA) and differential scanning calorimetry (DSC) are used to investigate the effect of molding and annealing of polyester on the behavior of thermal expansion and crystallization since these factors play role in the reprocessing or recycling of the polymer. The dynamic mode of the TMA provides enhanced characterization information about the polyester since it separates the transitions into reversible and irreversible signals, and also reveals the progress of the amorphous regions as the polyester loses strength with the increasing temperature approaching melting. Slow cooling after annealing brings crystallization that may be attributed to molecular chain straightening due to orientation.
This study aims to identify the level of quality of Islamic banking services in the Kingdom of Saudi Arabia. It also investigates the importance of the various dimensions of the quality of banking services. The sample of the study included 69 clients of Al Rajhi Bank and Al-Bilad Bank. The study concluded that the overall level quality of services that Islamic banking offer is high. However, their relative importance varies from one dimension to another. The security, confidence and physical aspects are very high which this is a good point. On the other hand, the application aspects do not get the same importance. These aspects include the customer's wishes, helping them to improve the services offered to them,
... Show MoreThe effect of D phase polyamide (PA6)on the rheological properties, Young Modulus and the thermal expansion coefficient of two blends groups (bitumen-polyamide) were tested. The first group was for bitumen-PA6 blends and the second group for bitumen blended with polymer resulted from the crystallization of PA6-formic acid solution in water(PAFW).The obtained results proved that adding both types of polyamide has led to a rise in toughness and softening point temperature while the penetration Index approached -3 after adding the polyamide. So, all these changes make bitumen-polyamide blends more suitable for use in hot climate regions. The blends properties were explained according to the reaction that takes place between the polyamide and
... Show More