Preferred Language
Articles
/
jbcd-446
Finite element stress analysis study for stresses around mandibular implant retained overdenture MIR-OD
...Show More Authors

Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Materials and methods: Eight models were constructed including four designs of anchorage system (ball-cup, ball-O Ring, bar without distal extension and bar with distal extension).The first group of models were supported by four dental implant and second group of models were supported by two dental implant only. Models constructed from the data obtained directly from patient The contour of bone was obtained from C.T scan image of patient, then data transferred to ANSYS program for modeling then load applied and solve the equation by the program, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD.. After load application, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD . Results: In the present study the stress distribution and maximum stresses value around dental implant had a relationship to the number of dental implant. , The result appeared that the maximum stresses and means of stresses value was lower in the first group of models (which was supported through the use four dental implant) than the second group of models (which was supported through the use of two dental implant only). For the first group of models the maximum stresses value around mesial implant was11.67, 10.51, 10.98 and 10.72 Mpa, while the maximum stresses around distal implant was 21.33, 18.51, 18.86, and17.56 Mpa for models 1,2,3 and 4respectively ,and the stresses around implant supporting second group of models was 22.52, 22.16, 20.51 and 19.60 Mpa for models 5,6,7and8 respectively .Statistical analyses of means value appeared that there was statistically significant difference in stresses means value around implant of the second group with that’s values around mesial and distal implant supporting first group of model . Regarding the result of both ball and bar system, it has been demonstrated that stress was greater with ball attachment and MIR-OD supported by the use of four dental implants and anchored by bar attachments with distal extension gives the minimum values of stresses than the rest models. Also the results show that higher stresses value was appeared at the cortical bone ring surrounding dental implant especially the distal implant nearest to the free end extension area. Also it was appeared that the best model was Mandible implant- retained overdenture that’s anchored by bar with distal extension and support by four dental implant. Conclusions: Bar-clips with distal extension mode of attachment considered the best type in producing the least stresses around dental implant regardless number of dental implant used.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Oct 08 2022
Journal Name
Mathematical Statistician And Engineering Applications
Illation for the Groups SL(2,112 ) and SL(2,132 )
...Show More Authors

Publication Date
Wed Jun 10 2009
Journal Name
Iraqi Journal Of Laser
A new achromatic glass for near infrared laser instruments
...Show More Authors

This research investigates new glasses which are best suitable for design of optical systems
working in the infrared region between 1.01 to 2.3μm. This work is extended to Oliva & Gennari
(1995,1998) research in which they found that the best known achromatic pairs are (BAF2-IRG2; SRF2-
IRG3; BAF2-IRG7; CAF2-IRGN6; BAF2-SF56A and BAF2-SF6). Schott will most probably stop the
production of these very little used and commercially uninteresting IRG glasses. In this work equally
good performances can be obtained by coupling BAF2, SRF2&CAF2 with standard glasses from Schott
or Ohara Company. The best new achromatic pairs found are (SRF2-S-TIH10; CAF2-S-LAL9; CAF2-SLAL13
and CAF2-S-BAH27). These new achromatic pai

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Optical properties for prepared polyaniline / Ferro fluid nano composites
...Show More Authors

Pure nano Ferro fluid was synthesized by chemical co-precipitation method. The composite of polyaniline with nano sized Ferro fluid was prepared by In-situ–chemical oxidation polymerization method with ammonium per sulphate as an oxidant in aqueous hydrochloric acid under constant stirring at room temperature. The optical properties, absorption, transmission, optical energy gap (Eg) and optical constant refractive index (n) have been investigated. The value of the Eg decreased with increasing Ferro fluid concentration.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Night Vision monitor for IR laser spot size Identification
...Show More Authors

The aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 10 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Evaluation of Domperidone Nanoemulsions for Oral Rout
...Show More Authors

          The aim of the present study is to formulate, evaluate and characterize the nanoemulsion of Domperidone a poorly water-soluble anti-emetic drug.

           Domperidone powder is white or almost white powder, photosensitive, practically insoluble in water, slightly soluble in ethanol and in methanol; soluble in dimethylformamide. It is used as an antiemetic for the short-term treatment of nausea and vomiting of various etiologies.

           Solubility studies were conducted to select the oil, surfactant and cosurfactant. Phase diagrams were constructed by aqueous phase

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Apr 21 2020
Journal Name
University Of Thi-qar Journal Of Science (university Of Thi-qar Journal Of Science (utsci) The 4th Scientific Conference Of Science College/ University Of Thi_qari) The 4th Scientific Conference Of Science College/ University Of Thi_qar
Enhancement of Nano Catalyst for an Alkaline Fuel Cells
...Show More Authors

Preview PDF
Publication Date
Wed Oct 18 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Personal Hygiene for Adults with Diabetic Foot
...Show More Authors

Objective: The aim of the study is to assess the personal hygiene of adult patients with
diabetic foot.
Methodology: ٨ descriptive study was carried out in Baghdad teaching hospital, Al-Karama teaching hospital
and Al-Kindey teaching hospital for the period of 10/1/2006 to 1/9/2006. A purposive "non probability" sample
of (100) patient.
Questionnaire was constructed for achieving the purpose of the study. Data were collected through the
application of the questionnaire and interview technique. Data were analyzed through descriptive statistical
approach (frequency & percentage) and inferential statistical approach (chi-square ع correlation) by using of
SPSS.
Results: The study results indicated that the ra

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 10 2020
Journal Name
Journal Of Inverse And Ill-posed Problems
Direct and inverse source problems for degenerate parabolic equations
...Show More Authors
Abstract<p>Degenerate parabolic partial differential equations (PDEs) with vanishing or unbounded leading coefficient make the PDE non-uniformly parabolic, and new theories need to be developed in the context of practical applications of such rather unstudied mathematical models arising in porous media, population dynamics, financial mathematics, etc. With this new challenge in mind, this paper considers investigating newly formulated direct and inverse problems associated with non-uniform parabolic PDEs where the leading space- and time-dependent coefficient is allowed to vanish on a non-empty, but zero measure, kernel set. In the context of inverse analysis, we consider the linear but ill-pose</p> ... Show More
View Publication
Scopus (28)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Mon Jun 04 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Darifenacin Hydrobromide loaded nanostructured lipid carrier for oral administration
...Show More Authors

Darifenacin hydrobromide is a selective ?3 receptor antimuscarinic drug and it is used in the management of urinary frequency, urgency, and incontinence in detrusor instability. It slightly soluble in water, undergoes extensive hepatic first-pass metabolism and has short elimination half-life (3–4 hours). Therefore, It has low bioavailability (15.4 % - 18.6 %). Darifenacin hydrobromide loaded NLCs were formulated by emulsification sonication using different ratios of solid lipid to liquid lipid, different types of surfactants, and different concentration of surfactants. Formula sixteen was considered as an optimized formula based on its particle size, PDI, zeta potential and entrapment efficiency. Formula sixteen subjected t

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (1)
Scopus Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Journal Of Engineering
Rotating Ceramic Water Filter Discs System for Water Filtration
...Show More Authors

This work aimed to design, construct and operate a new laboratory scale water filtration system. This system was used to examine the efficiency of two ceramic filter discs as a medium for water filtration. These filters were made from two different ceramic mixtures of local red clay, sawdust, and water.  The filtration system was designed with two rotating interfered modules of these filters.  Rotating these modules generates shear force between water and the surfaces of filter discs of the filtration modules that works to reduce thickness of layer of rejected materials on the filters surfaces. Each module consists of seven filtration units and each unit consists of two ceramic filter discs.    The average measured hy

... Show More
View Publication Preview PDF