Preferred Language
Articles
/
jbcd-446
Finite element stress analysis study for stresses around mandibular implant retained overdenture MIR-OD
...Show More Authors

Background: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Materials and methods: Eight models were constructed including four designs of anchorage system (ball-cup, ball-O Ring, bar without distal extension and bar with distal extension).The first group of models were supported by four dental implant and second group of models were supported by two dental implant only. Models constructed from the data obtained directly from patient The contour of bone was obtained from C.T scan image of patient, then data transferred to ANSYS program for modeling then load applied and solve the equation by the program, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD.. After load application, Specified nodes were selected at the rings of crestal bone (cortical bone) and cortical cancellous interface around each dental implant and fixed for all models to monitor the stress change in that regions of different design of MIR-OD . Results: In the present study the stress distribution and maximum stresses value around dental implant had a relationship to the number of dental implant. , The result appeared that the maximum stresses and means of stresses value was lower in the first group of models (which was supported through the use four dental implant) than the second group of models (which was supported through the use of two dental implant only). For the first group of models the maximum stresses value around mesial implant was11.67, 10.51, 10.98 and 10.72 Mpa, while the maximum stresses around distal implant was 21.33, 18.51, 18.86, and17.56 Mpa for models 1,2,3 and 4respectively ,and the stresses around implant supporting second group of models was 22.52, 22.16, 20.51 and 19.60 Mpa for models 5,6,7and8 respectively .Statistical analyses of means value appeared that there was statistically significant difference in stresses means value around implant of the second group with that’s values around mesial and distal implant supporting first group of model . Regarding the result of both ball and bar system, it has been demonstrated that stress was greater with ball attachment and MIR-OD supported by the use of four dental implants and anchored by bar attachments with distal extension gives the minimum values of stresses than the rest models. Also the results show that higher stresses value was appeared at the cortical bone ring surrounding dental implant especially the distal implant nearest to the free end extension area. Also it was appeared that the best model was Mandible implant- retained overdenture that’s anchored by bar with distal extension and support by four dental implant. Conclusions: Bar-clips with distal extension mode of attachment considered the best type in producing the least stresses around dental implant regardless number of dental implant used.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 07 2026
Journal Name
Al–bahith Al–a'alami
Evaluation in the Kurdish Media Institutions (A Descriptive Study Survey)
...Show More Authors

The importance of evaluation depends on many institutions, whether governmental or private, including media institutions, rely on the list to evaluate the weight of things and appreciation, as well as judging things, achievements, and everything related to the institution is concerned. Because through evaluation, institutions can recognize weaknesses and strengths. It is also an effective tool for management review, through which the institution can review everything related to planning and decision-making, leadership, incentives and other administrative matters.

Therefore, this study attempts to shed light on the evaluation process, its basics and its importance in general and in the Kurdish media institutions as a model in part

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2005
Journal Name
The Iraqi Journal Of Veterinary Medicine
Histological study of spleen in common Quail (Coturnix Coturnix Coturnix)
...Show More Authors

View Publication
Publication Date
Mon Feb 04 2019
Journal Name
Journal Of The College Of Education For Women
Married population of Baghdad (The study of the POPULATION geography)
...Show More Authors

The study found a number of results. The most prominent were the low married during the years of the study in 1997-2012. The study also showed the level of administrative units that the percentage of widows and single rise in urban and rural decline. This is due to the different nature of urban and rural society of the behavior and social habits and traditions.As the proportion of divorced and unmarried are decreased in urban and increase proportion in the countryside, and this is due to the influence of the rural population in the urban centers. As well as the study showed that there was a significant effect of the economic and social factors and other factors on marital status on its parts in the study area.

View Publication Preview PDF
Publication Date
Sat Sep 01 2007
Journal Name
Al-khwarizmi Engineering Journal
Parametric study of thermal behavior of thrust chamber cooling channels
...Show More Authors

A numerical investigation is adopted for two dimensional thermal analysis of rocket thrust chamber wall (RL10), employing finite difference model with iterative scheme (implemented under relaxation factor of 0.9 for convergence) to compute temperature distribution within thrust chamber  wall (which is composed of Nickel and Copper layers). The analysis is conducted for different boundary conditions: only convection boundary conditions then combined radiation, convection boundary conditions also for  different aspect ratio (AR) of cooling channel. The results show that Utilizing cooling channels of high aspect ratio leads to decrease in temperature variation across thrust chamber wall, while no effects on heat transferred to the

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 11 2021
Journal Name
Annals Of Tropical Medicine & Public Health
Morphological and Molecular Study of Biofilm Formation by Enterobacter cloacae
...Show More Authors

Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Study the Factors Effecting on Welding Joint of Dissimilar Metals
...Show More Authors

The aim of this work is to study the factors that affect the welding joint of dissimilar metals. Austenitic stainless steel-type AISI (316L) with a thickness of (2mm) was welded to carbon steel (1mm) using an MIG spot welding.  The filler metal is a welding wire of the type E80S-G (according to AWS) is used with (1.2mm) diameter and CO2 is used as shielding gas with flow rate (7L/min) for all times was used in this work.

        The results indicate that the increase of the welding current tends to increase the size of spot weld, and also increases the sheer force.  Whereas the sheer force increased inversely with the time of welding. Furthermore, the results indicate that i

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Bacterial Contamination of Acrylic Resin Complete Denture : In Vitro Study
...Show More Authors

Background: Cross contamination of dental appliances in the dental clinics and laboratories may potentially be a health hazard to the dental team and the patient. This study aimed to evaluate bacterial contamination of acrylic complete denture as received from dental laboratory before delivery to the patient, and then to evaluate the effectiveness of disinfection with 2% chlorhexidine and Kin denture cleaner tablet. Materials and methods: 45 newly made upper complete dentures undergone biaacterial examination for contamination before delivered to the patient. Samples were examined in two stages, first after finishing and polishing; when collected from the laboratory and before inserting to the patient mouth, second; after the samples were

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Oct 01 2021
Journal Name
Diyala Journal For Pure Science
Synthesis, Characterization and Computational Study of Discotic Liquid Crystal Compounds
...Show More Authors

Discotic liquid crystal compounds were synthesized and characterized. Liquid crystalline texture of these compounds was investigated by polarized optical microscopy (POM). The Hartree-Fock approximation (HF) was used to calculate theoretical molecular parameters for synthesized compounds such as optimization, hardness, EHOMO, ELUMO, and energy gap using the Gaussian 09W program.

View Publication
Crossref
Publication Date
Sat Feb 07 2026
Journal Name
Journal Of Al-turath University College
Implications of the political responsibility of the government (Comparative study)
...Show More Authors

View Publication
Publication Date
Mon Jan 01 2018
Journal Name
Biochem. Cell. Arch.
Comparative anatomical study of genus Oxalis L. (Oxalidaceae) in Iraq
...Show More Authors

The present study included the collection of fresh samples of species of genus Oxalis and examined the anatomical characteristics of the stem, scape, petiole, leaf and pedicel

Scopus (1)
Scopus