Background: The use of osseointegrated fixtures in dentistry has been demonstrated both histologically and clinically to be beneficial in providing long term oral rehabilitation in completely edentulous individual. Most patients suffer from denture instability; particularly with mandibular prosthesis, the use of dental implant will be benefit significantly from even a slight increase in retention. The concept of implanting two to four fixtures in a bony ridge to retain a complete denture prosthesis appealing therefore, as retention, stability and acceptable economic compromise to the expanse incurred with the multiple fixture supported fixed prosthesis. Materials and methods in this study the sample were eight patients selected from a hospital of specialized surgery, these patient were wearing a mandibular implant retained over denture for two years these patients having MIR-OD with Bar-clip, ball-cup and O- ring attachments. Preparative radiography was obtained for this patient from the center .these radiograph was taken to the patient at time of insertion. The second radiograph image was taken to the patient after two years of function with prosthesis. .the scanned images were transfer to special folder in a computer then analysis of bone loss done using Dimax software. After that an accurate calibrations of crestal bone measurement were analyzed for both groups of Radiography. Results it was appeared that the amount of bone loss in ball and bar designs (of mandibular Implant retained overdenture) were within the criteria of successful rate of bone loss during the period of examination, and there was statistically significant difference between both types of anchorage system. Conclusions The amount of bone loss was 0.1 mm after two years follow up, and it was within the acceptable limits of bone lose. A significant difference appeared between both designs of MIR-OD, Ball and bar designs.
Background: The insertion torque (IT) values and implant stability quotient (ISQ) values are the measurements most used to assess primary implant stability. This study aimed to assess the relationship between ISQ values and IT. Materials and methods: This study included 24 patients with a mean (SD) age of 47.9 (13.64) years (range 25-75 years). The patients received 42 dental implants (DI), 33 in the mandible and 9 in the maxilla. The DI were installed using the motorized method with 35 Ncm torque, When DI could not be inserted to the requisite depth by the motorized method, a hand ratchet was used and the IT was recorded as ˃ 35 Ncm. Implant stability was measured utilizing Osstell® ISQ. The secondary stability was measured after 16
... Show MoreBackground: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M
... Show MoreA cinematic shot is the basis of the film, regardless of the size, angle, or motion of this shot. However, the size of the footage and the process of showing or hiding the scene or cinematic personality has a certain speciality related to the nature of cinematic treatment and the type of the movie especially those characterized by the employment of the close-ups to induce ambiguity or spread the mental image of the dramatic events and this relationship between the close-up and horror films is what prompted the researcher to identify the title of the search as follows:
Dramatic utilization of Close-Up in Horror Movies
The research is divided as follows:
The methodological fram
... Show MoreThe study aimed to compare the expression of miR-126-3p and miR-423-5p in patients and normal subjects, and correlate their expression with response to induction therapy. Circulating miR-126-3p and miR-423-5p were measured in the plasma of 43 adult AML patients and 35 age- and sex-matched controls by real time PCR. The foldchange in differential expression for each gene was calculated using the comparative cycle threshold (CT) method (also known as the 2−CT method). For statistical purposes, the fold change was calculated using DDCT (or 2–∆∆Ct) method to find the relative expression of miRNAs. The expression fold change of miR-126-3p was 1.73-fold increase in patients than controls (p= 0.010). The expression fold change of miR-423-5
... Show MoreAbstract Background: Acute myeloid leukemia (AML) results from sequential genetic alterations in a normal hematopoietic stem cell or its progenitors giving rise to an autonomous clone that dominates the bone marrow leading to marrow failure. MicroRNAs are short non-coding nucleic acid sequences that regulate post-transcriptional gene expression by base-pairing with their target mRNAs. MiRNAs can be secreted into extracellular fluids and carried to target cells by vesicles or bound to proteins. Intracellular and circulating miRNAs are believed to be useful markers in the diagnosis, prognosis, and treatment of various cancers. Practically, circulating miRNAs are more stable at room temperatures and extreme conditions. Purpose: This study aim
... Show More