Background: The use of osseointegrated fixtures in dentistry has been demonstrated both histologically and clinically to be beneficial in providing long term oral rehabilitation in completely edentulous individual. Most patients suffer from denture instability; particularly with mandibular prosthesis, the use of dental implant will be benefit significantly from even a slight increase in retention. The concept of implanting two to four fixtures in a bony ridge to retain a complete denture prosthesis appealing therefore, as retention, stability and acceptable economic compromise to the expanse incurred with the multiple fixture supported fixed prosthesis. Materials and methods in this study the sample were eight patients selected from a hospital of specialized surgery, these patient were wearing a mandibular implant retained over denture for two years these patients having MIR-OD with Bar-clip, ball-cup and O- ring attachments. Preparative radiography was obtained for this patient from the center .these radiograph was taken to the patient at time of insertion. The second radiograph image was taken to the patient after two years of function with prosthesis. .the scanned images were transfer to special folder in a computer then analysis of bone loss done using Dimax software. After that an accurate calibrations of crestal bone measurement were analyzed for both groups of Radiography. Results it was appeared that the amount of bone loss in ball and bar designs (of mandibular Implant retained overdenture) were within the criteria of successful rate of bone loss during the period of examination, and there was statistically significant difference between both types of anchorage system. Conclusions The amount of bone loss was 0.1 mm after two years follow up, and it was within the acceptable limits of bone lose. A significant difference appeared between both designs of MIR-OD, Ball and bar designs.
In this work, plasma parameters such as (electron temperature (Te), electron density (ne), plasma frequency (fp) and Debye length (λD)) were studied using spectral analysis techniques. The spectrum of the plasma was recorded with different energy values, SnO2 and ZnO anesthetized at a different ratio (X = 0.2, 0.4 and 0.6) were recorded. Spectral study of this mixing in the air. The results showed electron density and electron temperature increase in zinc oxide: tin oxide alloy targets. It was located that The intensity of the lines increases in different laser peak powers when the laser peak power increases and then decreases when the force continues to increase.
Solar cells thin films were prepared using polyvinyl alcohol (PVA) as a thin film, with extract of natural pigment from local flower. A concentration of 0.1g/ml of polyvinyl alcohol solution in water was prepared for four samples, with various concentrations of plant pigment (0, 15, 25 and 50) % added to each of the four solutions separately for preparing (PVA with low concentrated dye , PVA with medium concentrated dye and PVA with high concentrated dye ) thin films respectively . Ultraviolet absorption regions were obtained by computerized UV-Visible (CECIL 2700). Optical properties including (absorbance, reflectance, absorption coefficient, energy gap and dielectric constant) via UV- Vis were tested, too. Fourier transform infra
... Show MoreFuture wireless networks will require advance physical-layer techniques to meet the requirements of Internet of Everything (IoE) applications and massive communication systems. To this end, a massive MIMO (m-MIMO) system is to date considered one of the key technologies for future wireless networks. This is due to the capability of m-MIMO to bring a significant improvement in the spectral efficiency and energy efficiency. However, designing an efficient downlink (DL) training sequence for fast channel state information (CSI) estimation, i.e., with limited coherence time, in a frequency division duplex (FDD) m-MIMO system when users exhibit different correlation patterns, i.e., span distinct channel covariance matrices, is to date ve
... Show MoreIn this work the effect of choosing tri-circular tube section had been addressed to minimize the end effector’s error, a comparison had been made between the tri-tube section and the traditional square cross section for a robot arm, the study shows that for the same weight of square section and tri-tube section the error may be reduced by about 33%.
A program had been built up by the use of MathCAD software to calculate the minimum weight of a square section robot arm that could with stand a given pay load and gives a minimum deflection. The second part of the program makes an optimization process for the dimension of the cross section and gives the dimensions of the tri-circular tube cross section that have the same weight of
... Show MoreAbstract
Objectives: The study is carried out to assess functional performance for heart's valve replacement patients and find out relationship with sociodemographic data and clinical data
Methodology: Descriptive design is carried out at cardiac surgery centers in Baghdad ; Ibn -Al Betar Specialized for cardiac surgery center and Al-Iraqi center for cardiac disease. its initiation from December28the 2013 to September 1st 2014,A non- probability (purposive) sample of 50 adults patients are attended cardiac surgery centers at Baghdad city and who have heart valves replacement. The data collection through development of questionnaire which is composed from three parts(socio demographic data, clinical information, functional performa
The present work focuses on the experimental implementation of one of the fiber optical sensors, the optical glass fiber built on surface Plasmon resonance. A type of optical glass fiber was used in this work, single-mode no-core fiber with pre-tapering diameter: (125.1 μm) and (125.3 μm), respectively. The taper method can be tested by measuring the output power of the optical fiber before and after chemical etching to show the difference in cladding diameter due to the effect of hydrofluoric acid with increasing time for the taper process. The optical glass fiber sensor can be fabricated using the taper method to reduce the cladding diameter of the fibers to (83.12 µm, 64.37 µm, and 52.45 µm) for single-mode fibers using Hydrofluoric
... Show Morepublishing has become a large space in the field of interactive education and modern pages have become dedicated to the service of the educational effort in this area as the research in this context of the urgent scientific necessities, especially as we consider in Iraq from the new countries in the exploitation of these new technologies and investment possibilities of the information network And the contents of different in the framework of so-called distance education Here lies the problem of research in the possibility of finding scientific solutions for the design of interactive inter active website for students of the preparatory stage in Iraq and to find out the scientific ways to find des
... Show MoreIn this study tungsten oxide and graphene oxide (GO-WO2.89) were successfully combined using the ultra-sonication method and embedded with polyphenylsulfone (PPSU) to prepare novel low-fouling membranes for ultrafiltration applications. The properties of the modified membranes and performance were investigated using Fourier-transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), contact angle (CA), water permeation flux, and bovine serum albumin (BSA) rejection. It was found that the modified PPSU membrane fabricated from 0.1 wt.% of GO-WO2.89 possessed the best characteristics, with a 40.82° contact angle and 92.94% porosity. The permeation flux of the best membrane was the highest. The pure water permeation f
... Show MoreMetallic nanoparticles are increasingly studied for their biomedical applications due to their unique physicochemical and catalytic properties. Here, a broccoli-mediated gold/platinum nanohybrid (Au@Pt NH) was synthesized using an ultrasound-assisted green method with an aqueous extract of Brassica oleracea var. italica for multifunctional biomedical evaluation. XRD and TEM confirmed a crystalline nanohybrid with an average crystallite size of 7.56 nm and a mean particle diameter of 13.08 ± 7.58 nm. The broccoli extract produced no inhibition zones, whereas Au@Pt NH inhibited Staphylococcus aureus (18 mm), Staphylococcus epidermidis (21 mm), Escherichia coli (18 mm), Klebsiella pneumoniae (20 mm), and Candida albicans (21 mm). In vivo,
... Show More