Preferred Language
Articles
/
jbcd-317
Comparison of metal ions release and corrosion potential from different bracket archwire combinations (An in vitro study)
...Show More Authors

Background: Esthetic treatment is the options of patient seeking orthodontic treatment. Therefore this study was conducted to measure the concentration of Aluminum, Nickel, Chromium and Iron ions released from combination of monocrysralline brackets with different arch wires immersed in artificial saliva at different duration, to evaluate the corrosion point on different parts of the orthodontic appliances before and after immersion in artificial saliva, and to evaluate the corrosion potential of each group of the orthodontic appliances. Material and methods: Eighty orthodontic sets prepared. Each set represents half fixed orthodontic appliance, from the central incisor to the first molar, for the maxillary arch, each set consisted of molar band, five brackets, half arch wire and ligature elastic.These sets are divided into two groups: Group A: with monocrystalline brackets divided into five subgroups (each subgroup has ten sets), but differ in arch wires, as numbered stainless steel, nickel-titanium, thermally activated, coated stainless steel and coated nickel-titanium arch wires respectively. Group B: with stainless steel brackets divided into three subgroups (also each subgroup has ten sets), but differ in arch wires, as numberedstainless steel, nickel-titanium, and thermally activated arch wires respectively. Used optical microscope to check the corrosion points, and used potentiostat techniques to indicate corrosion rate and tendency. Results: The greatest concentration of Aluminum and nickel ions release during the 1st week in group A, then sharply decreased in the 2nd week. The release of chromium ion released increase with increase intervals, while iron ion released decrease with increase time. Both nickel and chromium ions increase with increase intervals in group B,while iron increase to the maximum at 3rd weeks, then began to degrease. Optical microscope displayed pitting, crevices, and intergranular corrosion. Potentiostat techniques indicated that increase corrosion when used stainless steel and coated nickel titanium than others arch wires with group A, while corrosion increase with nickel titanium than stainless steel arch wires with group B. Conclusions: Non-significant difference in the total nickel, chromium and iron release in group B. Aluminum and iron increase in A4 and A5, while nickel and chromium increase in A1 and A2.The total released amounts of metals ions in both groups were less than the amounts of daily intake.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
مجلة الذكوات البيض
Assessing Accuracy and Interaction in a Speaking Test : AN Analytical study. تقييم الدقة و التفاعل في اختبار المحادثة: دراسة تحليلية
...Show More Authors

This paper deals with one of the most important issues in a foreign language teaching and learning, i.e. speaking test assessment. After giving a survey of literature written on the meaning and definition of a speaking test assessment, two sections have been devoted to tackle the most important issues in this topic. Section one, which is the theoretical part of this paper, sheds light on the basic definitions of the term ‘speaking assessment’ which are, according to the researcher’s point of view, sufficient to cover the area of the study. This section based on applied linguistic theories and researches in order to enhance our understanding of the what is meant by «a speaking test assessment«In addition,it explains the most importan

... Show More
Publication Date
Wed Apr 01 2020
Journal Name
Brazilian Dental Journal
In Vitro Homeostasis of Rat Oral Epithelial Cell Cultures Following Withdrawal of Periodontal Pathogens
...Show More Authors

Abstract Inflammation of periodontal tissues is the consequence of interaction between periodontal pathogens and immune system. This is associated with increased expression of inflammatory cytokines, which may exert destructive effect to the periodontal tissues when released over long period. The aim of this study was to chronologically track the homeostasis of oral keratinocytes following removal of periodontal pathogens. This was done by investigating expression of selected inflammatory markers and integrity of epithelial monolayers in vitro. Rat oral keratinocytes were stimulated with heat-killed Fusobacterium nucleatum and Porphyromonas gingivalis over 7-days then bacteria were washed away and epithelial cells re-cultured for 3-

... Show More
View Publication
Scopus (4)
Crossref (6)
Scopus Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Iraq Journal Of Agricultural Research
THE COMPARATIVE STUDY OF THE TOTAL COSTS AND NET REVENUE OF DIFFERENT TILLAGE SYSTEMS USING TWO TYPES OF SEEDLINGS IN THE PRODUCTION OF BARLEY GREEN VARIETY SAMEER IN THE GYPSUM SOILS
...Show More Authors

Publication Date
Fri Oct 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
The effect of applying total quality management on the competitiveness from the point of view of the front-rows employees for customer service (An analytical study of Palestinian local banks)
...Show More Authors

The study aimed to identify the effect of Total Quality Management on enhancing competitiveness through the opinions of employees of the front- rows of customer service in local Palestinian banks, the researcher adopted an analytical descriptive method through developing a special questionnaire to accomplish the study’s objectives and answer its questions. The study involved all the Palestinian local banks, with their scattered branches in West Bank. The study sample consisted of 3470 executive employees for banking services out of 4753 employees, in the rate of 73%, and the study sample reached (485) employees who were randomly selected working in the front -rows to provide services in the local Palestinian banks during the ye

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 01 2015
Journal Name
International Journal Of Engineering Sciences & Research Technology
IMPROVEMENT THE MECHANICAL WEAR RESISTANCE OF METAL KNIFE USED IN HARVESTER MACHINE
...Show More Authors

SKF Dr. Abbas S. Alwan, Dhurgham I. Khudher, INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY, 2015

View Publication Preview PDF
Publication Date
Thu Feb 26 2026
Journal Name
Int. J. Corros. Scale Inhib.
DFT and experimental investigation of a novel 1,2,4-triazole derivative as a corrosion inhibitor for carbon steel A106 G/B in HCl solution
...Show More Authors

This work introduces a newly synthesized triazole derivative, 5-([(2-furanyl)methyl]-thiomethyl)-4-(naphtha-2-yl)-3-hydroxyl-4H-1,2,4-triazole (FTNT), as an effective corrosion inhibitor for carbon steel A106 G/B in 0.1 M HCl solution. The structure of the novel derivative was confirmed by FTIR, 1 H NMR, and 13 C NMR spectra. Potentiodynamic polarization measurements reveal that FTNT markedly suppresses corrosion, with inhibition efficiency reaching 81.6% at 600 ppm. Thermodynamic analysis indicates spontaneous, physisorption/chemisorption-augmented adsorption of FTNT on the steel surface, best described by the Freundlich isotherm. Atomic force microscopy (AFM) surface examination demonstrated that a protective FTNT coating precipitated on

... Show More
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Osseointegration & Oral Rehablitation
Evaluation of marginal bone loss around SLActive implants by CBCT using different implant dimensions and surgical approaches: A clinical and radiological prospective study
...Show More Authors

Aim: The reduction in the amount of marginal bone is the most important demand for the long term success of dental implants. This prospective clinical study was aimed to investigate the marginal bone loss of early loaded SLActive implants with different dimensions and surgical approaches. Materials and methods Fifteen patients aged from 18 to 60 years were divided into 2 groups (flapped and flapless approach) that underwent delayed implant placement protocol with SLActive implants. The marginal bone level was estimated by cone-beam computed tomography during three different periods: preoperatively, 8 weeks after surgery and 24 weeks after loading of the prosthesis. Results: The mean value of marginal bone level was not significantly chan

... Show More
View Publication Preview PDF
Scopus (6)
Scopus
Publication Date
Thu Dec 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Influence of Temperature and Flow Velocity on the Corrosion Inhibition of Low Carbon Tubes in Recirculating Water System by a Dicomponent Inhibitor Blend
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Theoretical calculation for sputtering yield of beryllium copper alloy bombarded by Argon, nitrogen and oxygen ions
...Show More Authors

View Publication
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Feb 01 2020
Journal Name
Journal Of Water Process Engineering
Immobilization of cobalt ions using hierarchically porous 4A zeolite-based carbon composites: Ion-exchange and solidification
...Show More Authors

View Publication
Scopus (65)
Crossref (56)
Scopus Clarivate Crossref