Background: Chronic kidney disease is a gradual loss of kidney function with diabetes and hypertension as the leading cause. Chronic kidney disease is one of these systemic diseases that can affect salivary contents. Aims: This study aimed to assess salivary immunoglobulin A, interleukin-6 and C- reactive protein in chronic kidney disease patients on hemodialysis and those on conservative treatment in comparison with control subjects. Materials and methods: Ninety subjects were included in this study divided into three groups: 30 patients with chronic kidney disease on hemodialysis for at least 6 months ago; 30 patients with chronic kidney disease on conservative treatment and 30 healthy control subjects. Secretory immunoglobulin A, interleukin-6 and C- reactive protein in saliva samples were measured by enzyme-linked immunosorbent assay ELISA. Results: No significant difference in salivary immunoglobulin A level among study groups was seen. A significant increase in salivary interleukin-6 and C- reactive protein in both chronic kidney disease patients on hemodialysis and those on conservative treatment compared to the control group. While, no significant salivary IL-6 and CRP differences were seen between both patient groups, on hemodialysis and conservative treatment. Conclusions: There was no significant difference among chronic kidney disease patients on hemodialysis, on conservative treatment and control healthy subjects regarding to salivary IgA while Salivary interleukin -6 and C- reactive protein was significantly higher in chronic kidney disease patients on hemodialysis and those on conservative treatment compared to healthy subjects.
Film condensation of steam on a vertical tube is investigated numerically and experimentally, in the present work. A mathematical model was set based on the basic conservation laws of mass and energy, Nusselts analysis of film condensation, and empirical equations available in the literature. Then, a simulation program in FORTRAN language was developed which simulates the film condensation of steam on a vertical tube. A complete steam tables subprogram was also developed and incorporated with the main program. The experimental work was carried out using a steam condensation test bench. The inlet and outlet cooling water temperatures, steam temperature and pressure, tube surface temperature at center, and co
... Show MoreBackground: MicroRNAs (miRNAs) are small noncoding RNAs that postâ€transcriptionally regulate gene expression by targeting specific mRNAs. The main objective of this study was measure the level of salivary (hsa-miR-200a, hsa-miR-125a and hsa- miR-93) in both oral squamous cell carcinoma and healthy controls to asses the association of them with age, gender and tumor grade materials and methods The level of three salivary microRNAs namely hsa-miR-200a, hsa-miR-125a and hsa- miR-93 were measured in saliva of patients with oral squamous cell carcinoma and healthy controls by using reveres transcription, preamplification and quantitative PCR also the general information from each patient including the age, sex and tumor grade were record
... Show MoreBackground: Pleomorphic adenoma is the most common benign salivary gland tumor and shows a pronounced morphological complexity and diversity; for this The immunoprofiles and clinical course of PA differed according to cellular differentiation. Therefore, it is important to assess potential biomarkers in diagnostic and therapeutic trials. This study evaluates the immunohistochemical expression of D2-40, VEGF and PCNA as markers of lymphangiogenesis, angiogenesis and proliferation of PA and their correlation with clinicpathological parameters and with each other. Materials and Methods: Twenty five formalin – fixed, paraffin – embedded tissue blocks were included in this study. After histopathological reassessment of haematoxylin & eosin
... Show MoreWhen a vehicle is left parked in the sun for an extended period, the gathered heat causes damage to several interiors within the cabin and causes discomfort for people and animals left inside the car. In the present work, the effect of the orientation of a parked white minibus on temperature distribution and cooling load calculation is studied experimentally in an open environment. Two different cases were studied facing south and facing east. For several hours, the temperature inside the car cabin had been monitored and measured at five separate locations. The cooling load calculations are carried out based on the experimental measurements. The results show that the overheating of parked cars always happens as a result
... Show MoreThis study was undertaken to diagnose routine settling problems within a third-party oil and gas companies’ Mono-Ethylene Glycol (MEG) regeneration system. Two primary issues were identified including; a) low particle size (<40 μm) resulting in poor settlement within high viscosity MEG solution and b) exposure to hydrocarbon condensate causing modification of particle surface properties through oil-wetting of the particle surface. Analysis of oil-wetted quartz and iron carbonate (FeCO₃) settlement behavior found a greater tendency to remain suspended in the solution and be removed in the rich MEG effluent stream or to strongly float and accumulate at the liquid-vapor interface in comparison to naturally water-wetted particles. As su
... Show More