Background: Gingival crevice fluid (GCF) is a mixture of substances derived from serum, leukocytes, and structural cells of periodontium and oral bacteria. These substances possess a great potential for serving as indicators of periodontal disease and healing after therapy the main purpose of this study was to find if there is a difference in albumin concentration between healthy and diseased periodontal tissues and to compare between diseased group according to pocket depth Materials and methods: total sample composed of 60 pockets found in 35 patients all of them had no history of any systemic disease, The samples were divided in to three main group that include two diseased groups divided according to the depth of the periodontal pocket (group I were the pocket depth less than 6mm and group II were the pocket depth is equal or more than 6mm) and one healthy group (group III). Sampling of GCF were taken from patients in the second visits of periodontal treatment A previously weighed strips of filter paper size 30 were gently inserted in to the selected pocket depth until resistance was felt the filter paper left in place for 30 seconds and after removal they were weighed on a chemical balance. The difference between the weights of filter paper before and after absorption of exudates was calculated and each filter strips was placed in a tube containing o.3ml of normal saline then transferred and stored at -20C.on the day of analysis the samples were centrifuged at 10.000rpm for 20 minutes .the supernatant was used for assessment of Albunim colorimetrically similar to that of blood. Results: Comparison for gingival fluid weight were shown a non significant difference in the weight between group I&II at a P values >0.05 while there were a highly significant difference between group I&III and between group II&III at P values 0.05 intra groups correlation between albumin content in gingival fluid and periodontal parameter there were a significant negative correlation between plaque index and albumin in group I and II while anon significant correlation in group III also a significant and highly significant correlation were found between albumin and weight of gingival fluid in group I and II while anon significant differences in group III as shown in the table while there were anon significant differences between albumin content of gingival fluid and the gingival index, probing pocket depth and clinical attachment loss. Conclusion: the gingival crevicular fluid is an aqueous component in which is true trasudate and inflammatory exudates after the initial periodontal treatment in which it increased in weight as the inflammation present but the concentration of albumin may became a no significantly different compared with clinically healthy gingiva. As the initial periodontal treatment took place for each patients.
<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con
... Show MoreSynthesis of a new class of Schiff-base ligand with a tetrazole moiety to form polymeric metal complexes with CoII, NiII, ZnII, and CdII ions has been demonstrated. The ligand was synthesised by a multi-steps by treating 5-amino-2-chlorobenzonitrile and cyclohexane -1,3-dione, the 5,5'-(((1E,3E)-cyclohexane-1,3-diylidene)bis(azanylylidene))bis(2-chlorobenzonitrile) was obtained. The precursor (M) was prepared from the reaction 5,5'-(((1E,3E)-cyclohexane-1,3-diylidene)bis(azanylylidene))bis(2-chlorobenzonitrile) with NaN3 to obtained (1E,3E)-N1,N3-bis(4-chloro-3-(1H-tetrazol-5-yl)phenyl)cyclohexane-1,3-diimine (N). By reacting the precursor (M) with CS2
... Show MoreIn this study, the new azo dye,5,5-[1,2-phenylenebis(2,1-biazenediyl)] bis[8-quinolino], was used to synthesize complexes with Co2+, Ni2+, Cu2+, Zn2+, and Cd2+ ions. The compounds were characterized using 1H and 13C nuclear magnetic resonance (NMR) spectroscopy, Fourier transform infrared (FT-IR) spectroscopy, ultraviolet-visible (UV-Vis) spectroscopy, mass spectrometry, thermo gravimetric analysis (TGA), diffevential scanning calovimltry (DSC), CHN analysis. Further, conductivity, magnetic susceptibility, and metal and chlorine content analysis using FT-IR spectroscopy revealed that the ligand chelates as a bidentate (OH) phenol group and a bidentate (C=N) ring group. The ligand exhibited tetradentate behavior, forming tetrahedral complexe
... Show MoreIt is often needed to have circuits that can display the decimal representation of a binary number and specifically in this paper on a 7-segment display. In this paper a circuit that can display the decimal equivalent of an n-bit binary number is designed and it’s behavior is described using Verilog Hardware Descriptive Language (HDL). This HDL program is then used to configure an FPGA to implement the designed circuit.
six specimens of the Hg0.5Pb0.5Ba2Ca2Cu3-y
In this study, the activity concentrations of indoor radon, thoron
and their progeny have been measured in air for 61 different
locations of Al-Maddan city using twin cup dosimeter. Furthermore,
some useful parameters concerning the health hazards have been
estimated; working level month (WLM), annual effective dose (Eff),
and excess lung cancer per million person per year (ELC).The results
show that the values of radon gas levels in the investigated districts
varied from 56.28 to 194.43Bq/m3with an overall average value
132.96Bq/m3, while 0.313 to 1.085 for WLM with an overall average
0.740, respectively. The value of Eff and ELC have been found to
vary from 1.420 to 4.918 mSv/y with an overall average valu