Background: Implant stability is a mandatory factor for dental implant (DI) osseointegration and long-term success. The aim of this study was to evaluate the effect of implant length, diameter, and recipient jaw on the pre- and post-functional loading stability. Materials and methods: This study included 17 healthy patients with an age range of 24-61 years. Twenty-two DI were inserted into healed extraction sockets to replace missing tooth/ teeth in premolar and molar regions in upper and lower jaws. Implant stability was measured for each implant and was recorded as implant stability quotient (ISQ) immediately (ISQ0), and at 8 (ISQ8) and 12 (ISQ12) weeks postoperatively, as well as post-functional loading (ISQPFL). The pattern of implant stability changes throughout the study period and its correlation with the recipient jaw and the DI dimensions were evaluated. Results: There was a significant difference in ISQ values throughout the study. DI stability in the maxilla was significantly higher than that in mandible for the ISQ0, with no significant effect for the rest time points. The effect of implant diameter was significant with DI of 4.1mm diameter being more stable. While for the length, there was no significant difference regarding its effect on ISQ values through-out the study period. Conclusions: DI inserted in the maxilla demonstrated better primary stability with no effect of recipient jaw on secondary stability and after functional loading, also DI with wider diameter had better stability throughout the study whereas DI length showed no significant effect on stability
Background: Calcaneus is a spongy cancellous bone with rich blood supply , its fracture heals more rapidly providing no occurrence of infection and soft tissue injury around ,no gross malposition of fragments. The associated pain leads to a major impairment in life quality. The aim of treatment for calcaneal fractures is the decrease of pain and rebuilding of walking ability for patients with normal foot shape and the ability to wear normal foot wear. To reduce complications, a minimally invasive technique for the treatment of displaced intra-articular fractures of the calcaneus was preferred to use.
The purpose of this study was to determine whether the closed reduction and percutaneous K. wire fixation of displ
... Show MoreThe present study aims to get experimentally a deeper understanding of the efficiency of carbon fiber-reinforced polymer (CFRP) sheets applied to improve the torsional behavior of L-shaped reinforced concrete spandrel beams in which their ledges were loaded in two stages under monotonic loading. An experimental program was conducted on spandrel beams considering different key parameters including the cross-sectional aspect ratio (
In this work, Co-Y-oxide Nano Structure is successfully synthesized via hydrothermal method. The XRD analysis, SEM analysis, optical, electrical and photo sensing properties have been investigated for Co3O4 and Co-Y-oxide thin films. The X-ray diffraction (XRD) analysis reveals that all films are polycrystalline in nature, having cubic structure. The SEM images of thin films clearly indicates that Co3O4 possesses nanosphere like structure and flower like for Co-Y-oxide. The optical properties show that the optical energy gap follows allowed direct electronic transition calculated using Tauc equation and it increases for Co-Y-oxide. The photo sensing properties of thin films are investigated as a function of time at different wavelengths to
... Show MoreAbstract Objectives: The study aims to evaluate the nurses' practices that concerning intravenous chemotherapy infusion and to find out the association between nurses' practices and their level of education, year of experiences, and training course.
Methodology: A descriptive study was conducted in Baghdad Teaching Hospital and Al Amal National Hospital for Treatment of Tumors for the purpose of evaluating the practices of nurses related to infusion of intravenous chemotherapy for the period from 20th October 2017 to 14th March 2018. The sample was randomly selected from both hospitals. Who were evaluated by using a checklist to observe their practices which consisted of two parts; the first part included the demographic information
Background: Normal Left Ventricular systolic function is present in nearly 50% of patients with congestive heart failure, the majority of such patients have systemic hypertension. Recent studies have demonstrated Left Ventricular dyssynchrony among patients with heart failure and normal systolic function. The co-existence between Left Ventricular dyssynchrony and hypertension with normal systolic function (with no clinical evidence of heart failure) is less well understood.
Objective:
To assess the Left Ventricular dyssynchrony among hypertensive patients with normal systolic function by using Tissue doppler imaging.To find out the associations between the LV dyssynchrony and other global
... Show MoreBackground: Congenital cardiac defects have a wide spectrum of severity in infants. About 30-40% of patients with congenital cardiac defects will be symptomatic in the 1st year of life, while the diagnosis was established in 60% of patients by the 1st month of age.
Objectives: To identify the occurrence of specific types of CHD among hospitalized patients and to evaluate of growth of patients by different congenital heart lesions.
Methods: A retrospective study, done on ninety-six patients (51 male and 45 female) with congenital heart disease (CHD) admitted to central teaching hospital of pediatrics, Baghdad from 1st September 2009 to 30
Impact strength of self-compacted concrete is a field of interest, mostly when the concrete is produced from sustainable materials. This research's main objective is to clarify the ability to use two types of Portland limestone cement (Karasta and Tasluja) in self compacted concrete under impact loading, further to the economic and environmental benefits of the limestone cement. The impact loading was applied by a low-speed test, using the drop ball on concrete. Moreover, the study reveals the resistance of the grids reinforced concrete to impact loading by using polymer grid, and steel grid reinforced concrete slabs. Mixes reinforced by steel mesh had the highest results, indicating that the steel mesh was more robust because it had
... Show More