Background: Implant stability is a mandatory factor for dental implant (DI) osseointegration and long-term success. The aim of this study was to evaluate the effect of implant length, diameter, and recipient jaw on the pre- and post-functional loading stability. Materials and methods: This study included 17 healthy patients with an age range of 24-61 years. Twenty-two DI were inserted into healed extraction sockets to replace missing tooth/ teeth in premolar and molar regions in upper and lower jaws. Implant stability was measured for each implant and was recorded as implant stability quotient (ISQ) immediately (ISQ0), and at 8 (ISQ8) and 12 (ISQ12) weeks postoperatively, as well as post-functional loading (ISQPFL). The pattern of implant stability changes throughout the study period and its correlation with the recipient jaw and the DI dimensions were evaluated. Results: There was a significant difference in ISQ values throughout the study. DI stability in the maxilla was significantly higher than that in mandible for the ISQ0, with no significant effect for the rest time points. The effect of implant diameter was significant with DI of 4.1mm diameter being more stable. While for the length, there was no significant difference regarding its effect on ISQ values through-out the study period. Conclusions: DI inserted in the maxilla demonstrated better primary stability with no effect of recipient jaw on secondary stability and after functional loading, also DI with wider diameter had better stability throughout the study whereas DI length showed no significant effect on stability
The current study is designed to achieve the goal of early detection of heart disease because it is the main risk of death. Some biomarkers were measured as well as the percentage of the effect of certain risk factors in people with myocardial infarction and heart failure. The study included 40 serum samples from people with heart disease. The effectiveness of the creatine kinase (CK-MB), as well as its temporal and albumin effects, as well as sodium ions in people with myocardial infarction and heart failure, were compared with the control group. as shown below:
-The first group consisted of 25 blood samples from people with myocardial infarction and 15 serum samples from people with heart failure. Blood
... Show MoreIn this research TiO2 nano-powder was prepared by a spray pyrolysis technique and then adds to the TiO2 powder with particle size (0.523 μm) in ratio (0, 5, 10, 15 at %) atomic percentage, and then deposition of the mixture on the stainless steel 316 L substrate in order to use in medical and industrial applications.
Structure properties including x-ray diffraction (XRD) and scanning electron microscope (SEM0, also some of mechanical properties and the effect of thermal annealing in different temperature have been studied. The results show that the particle size of a prepared nano-powder was 50 up to 75 nm from SEM, and the crystal structure of the powders (original and nano powder) was rutile with tetragonal cell. An improvement in
A field experiment was carried out during the 2020 season at the College of Agricultural Engineering/ University of Baghdad, Al-Jadriya to evaluate the effect of dry farming when applying water stress under the subsurface drip irrigation system on water productivity and rice yield. The experiment was conducted with three levels of irrigation water stress when 10, 20 and 40% of the available water was depleted and in three dimensions between drip lines 10, 15 and 20 cm. The experiment was designed according to a randomized complete block design, according to the split plot design, with three replications. Determine the depth of irrigation water depending on the moisture depletion of th
The effect of thermal treatment on optical constants of pure PMMA and with addition (15 and 35) ml of coumarin at different temperatures (100, 110 and 120) C0 for 1 hour were investigated. Cast method used to prepares films of pure PMMA and PMMA with (15 and 35) of coumarin. UV/VIS spectrometer technique used to measure the absorption spectra for these films. The optical constant (absorption spectra and absorption coefficient) don’t changes after applied temperatures in pure PMMA film but the optical constant (absorption spectra and absorption coefficient) in PMMA with (15 and 35) ml of coumarin increased with applied temperatures. The optical energy gap of pure PMMA and PMMA with (15 and 35) ml of coumarin sl
... Show MoreIn this study, the behavior of screw piles models with continuous helix was studied by conducting laboratory experimental tests on a single screw pile that has several aspect ratios (L/D) under the influence of static axial compression loads. The screw piles were inserted in a soft soil that has a unit weight of 18.72 kN/m3 and moisture content of 30.19%. Also, the soil has a liquid limit of 55% and a plasticity index of 32%. A physical laboratory model was designed to investigate the ultimate compression capacity of the screw pile and measure the generated porewater pressure during the loading process. The bedding soil was prepared according to the field unit weight and moisture content and the failure load was assumed correspondin
... Show MoreIt is believed that culture plays an important role in the ELF classroom activities (Al- Mutawa, & Kilani, 1989:87). It is important for the teacher to recognize potential negative (culturally based) perceptions of their learners. In Iraq, for instance, it is not. Uncommon to meet silent expressionless students that arc supposedly English language learners. It is possible for the beginner to interpret this negatively as a lack of interest in the study of English. This interpretation may play a harmful role in the classroom methodology. An instructor has to be intercultural competent to be an effective teacher. It will be more effective if the instructor adopts a consistent style of instruction to allow learners to adapt within the bounds of
... Show MoreAbstract
One of the most suitable materials to be used in latent heat thermal energy storage system (LHTES) are Phase change materials, but a problem of slow melting and solidification processes made many researchers focusing on how to improve their thermal properties. This experimental work concerned with the enhancing of thermal conductivity of phase change material. The enhancing method was by the addition of copper Lessing rings in phase change material (paraffin wax). The effect of diameter for the used rings was studied by using two different diameters (0.5 cm and 1cm). Also, three volumetric percentages of rings addition (3%, 6% and 10%) were tested for each diameter. The discharging process was done with
... Show MoreSearch Results at the International Journal of Science and Research (IJSR)