Background: The Titanium and its alloys are suitable for dental implant and medical applications. Biocompatibility of the materials is a major factor in determining the success of the implant and has a great impact on their rate of osseointegration. The aim of this study was to evaluate the biocompatibility and cytotoxicity of Ti2AlC in comparison to CPTi & Ti6Al7Nb in rabbits. Materials and Methods: 10 male New Zealand White rabbits, weighing (2-2.5 kg), aged (10-12 months) were used in this study. Cylindrical implants were prepared from the study materials (CPTi, Ti6Al7Nb and Ti2AlC) with (8mm) height and (3mm) diameter for the evaluation of tissue response and disc specimens were prepared with (6 mm) diameter and (2 mm) thickness for evaluation of cytotoxicity MTT test. A histological study was performed at 2 & 6 weeks post- surgical implant insertion. Results: Histological findings show that Ti2AlC has enhanced proliferation of osteo-progenitor cell and reported mature bone formation at 6 weeks. Moreover, Ti2AlC has recorded a higher percentage for viable cells by MTT test in comparison to CPTi and Ti6Al7Nb. Conclusion: The new Ti2AlC dental implant is considered biocompatible and has showed a better bone formation than the CPTi and Ti6Al7Nb materials at 2 & 6 weeks.
The use of biopolymer material Chitosan impregnated granular activated carbon CHGAC as adsorbent in the removal of lead ions pb.2+ from aqueous solution was studied using batch adsorption mode. The prepared CHGAC was characterized by Scanning Electronic Microscopy (SEM) and atomic-absorption pectrophotometer. The adsorption of lead ions onto Chitosan-impregnated granular activated carbon was examined as a function of adsorbent weight, pH and
contact time in Batch system. Langmuir and Freundlich models were employed to analyze the resulting experimental data demonstrated that better fitted by Langmuir isotherm model than Freundlich model, with good correlation coefficient. The maximum adsorption capacity calculated f
Treatment of a high strength acidic industrial wastewater was attempted by activated carbon
adsorption to evaluate the feasibility of yielding effluents of reusable qualities. The experimental
methods which were employed in this investigation included batch and column studies. The
former was used to evaluate the rate and equilibrium of carbon adsorption, while the latter was
used to determine treatment efficiencies and performance characteristics. Fixed bed and expanded
bed adsorbers were constructed in the column studies. In this study, the adsorption behavior of acetic acid onto activated carbon was examined as a function of the concentration of the adsorbate, contact time and adsorbent dosage. The adsorption data was mo
This paper presents the ability to use cheap adsorbent (corn leaf) for the removal of Malachite Green (MG) dye from its aqueous solution. A batch mode was used to study several factors, dye concentration (50-150) ppm, adsorbent dosage (0.5-2.5) g/L, contact time (1-4) day, pH (2-10), and temperature (30-60) The results indicated that the removal efficiency increases with the increase of adsorbent dosage and contact time, while inversely proportional to the increase in pH and temperature. An SEM device characterized the adsorbent corn leaves. The adsorption's resulting data were in agreement with Freundlich isotherm according to the regression analysis, and the kinetics data followed pseudo-first-or
... Show MoreThe study investigates the water quality of the Orontes River, which is considered one of the important water recourses in Syria, as it is used for drinking, irrigation, swimming and industrial needs. A database of 660 measurements for 13 parameters concentrations used, were taken from 11 monitoring points distributed along the Orontes River for a period of five years from 2015-2019, and to study the correlation between parameters and their impact on water quality, statistical analysis was applied using (SPSS) program. Cluster analysis was applied in order to classify the pollution areas along the river, and two groups were given: (low pollution - high pollution), where the areas were classified according to the sources of pollution to w
... Show MoreThe objective of this research is to know the economic feasibility of hydroponics technology by estimating the expected demand for green forage for the years 2021-2031 as well as Identify and analyze project data and information in a way that helps the investor make the appropriate investment decision in addition to preparing a detailed technical preliminary study for the cultivar barley project focusing on the commercial and financing aspects and the criteria that take into account the risks and uncertainties . that indicating the economic feasibility of the project to produce green forage using hydroponics technology. Cultured barley as a product falls within the blue ocean strategy. Accordingly, the research recommends the necess
... Show MoreChromene is considered a fused pyran ring with a benzene ring, which is found in many plants and is part of many important compounds such as anthocyanidins, anthocyanins, catechins, and flavanones. These compounds are included under the headings "flavonoids" and "isoflavonoids." These compounds are well known as bioactive molecules with wide medicinal uses. According to these pharmacokinetic characteristics, many researchers are giving more attention to this type of compound and its derivatives. Many chromene derivatives have been synthesized to study their biological effects for the treatment of many diseases. Furthermore, the researcher displayed wide interest in finding new methods for synthesizing chromene derivatives. These met
... Show MoreTo investigate the efficacy of polyether‐ether‐ketone (PEEK) wire as a fixed orthodontic retainer, by comparing its performance to other retainer wires and optimizing its adhesion to composite bonding materials.
Retainer wires of 15 mm segments were used, PEEK wires were prepared in cylindrical form with 0.8 mm diameter, and had two surface treatments namely air‐abrasion and conditioning with adhesive system. Three different metallic retainer wires were used for comparison and three tests were performed; two tests measured debonding force and associated wire deflec