Background: Morphology of the root canal system is divergent and unpredictable, and rather linked to clinical complications, which directly affect the treatment outcome. This objective necessitates continuous informative update of the effective clinical and laboratory methods for identifying this anatomy, and classification systems suitable for communication and interpretation in different situations. Data: Only electronic published papers were searched within this review. Sources: “PubMed” website was the only source used to search for data by using the following keywords "root", "canal", "morphology", "classification". Study selection: 153 most relevant papers to the topic were selected, especially the original articles and review papers, from 1970 till the 28th of July 2021. Conclusions: This review divided the root canal analysis methods into two approaches; clinical and in vitro techniques. The latter has shown more precise non-subjective readings, on the other hand; the clinical methods provide direct chair side diagnosis for the clinical cases. The classification systems reviewed in the present study, started with the oldest trials that simply presented the root canal systems, according to the degree of angulation, or by coded Latin numbers or English letters. Then, the most recent systems were also presented that were persisted with continuous editions up to date. These new systems could briefly describe the root and root canal’s internal and external details in a small formulation, without confusion and in an easily communicated manner, highly recommended specially for students, teachers, and researchers
This paper analyzes the effect of scaling-up model and acceleration history on seismic response of closed-ended pipe pile using a finite element modeling approach and the findings of 1 g shaking table tests of a pile embedded in dry and saturated soils. A number of scaling laws were used to create the numerical modeling according to the data obtained from 1 g shake table tests performed in the laboratory. The current study found that the behaviors of the scaled models, in general have similar trends. From numerical modeling on both the dry and saturated sands, the normalized lateral displacement, bending moment, and vertical displacement of piles with scale factors of 2 and 35 are less than those of the pile with a scale factor of 1 and the
... Show MoreAutorías: Omar Saeed Sabbar, Ali Mousa Jawad, Maher Amer Jabbar. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 3, 2023. Artículo de Revista en Dialnet.
Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreCumulative lifetime lead (Pb) exposure has been associated with accelerated declines in cognition through the free radical generation and epigenetic effects. Several pieces of literature have identified a correlation between exposure to lead and neurodegenerative disorders. Harwich strain Drosophila melanogaster was exposed to lead acetate for two weeks, and changes in pulse transmission by acetylcholinesterase and systemic redox were evaluated. Besides, molecular docking studies of acetylcholinesterase against Quercetin and its most common derivatives contained in food have been performed. Pharmacokinetic studies on Quercetin and its derivatives have also been performed in silico toxicity. The data obtained showed alterations in antioxi
... Show MoreRegression Discontinuity (RD) means a study that exposes a definite group to the effect of a treatment. The uniqueness of this design lies in classifying the study population into two groups based on a specific threshold limit or regression point, and this point is determined in advance according to the terms of the study and its requirements. Thus , thinking was focused on finding a solution to the issue of workers retirement and trying to propose a scenario to attract the idea of granting an end-of-service reward to fill the gap ( discontinuity point) if it had not been granted. The regression discontinuity method has been used to study and to estimate the effect of the end -service reward on the cutoff of insured workers as well as t
... Show More