Preferred Language
Articles
/
jbcd-296
A comparative study to evaluate the shear bond strength of different resin sealers to dentin (An in vitro study)
...Show More Authors

Background: One of the major problems in endodontics is micro-leakage of root canal fillings which might contribute to the failure of endodontic treatment. To avoid this problem, a variety of sealers have been tested. The objective of this, in vitro, study was to evaluate the shear bond strength of four resin based sealers (AH plus, silver free AH26, RealSeal SE and Perma Evolution permanent root canal filling material) to dentin. Materials and Methods: Forty non-carious extracted lower premolars were used. The 2mm of the occlusal surfaces of teeth were sectioned, to expose the dentin surface. The exposed dentin surfaces of teeth were washed with 5ml of 2.5% NaOCl solution followed by 5ml of 17 % EDTA then rinsed by deionized water to remove the smear layer. The teeth were divided into four groups according to the type of sealer used: Group A: silver free AH26, Group B: AH plus., Group C: RealSeal SE, Group D: Perma Evolution. Polyethylene tube cylinders (4mm internal diameter & 5mm length) were fixed on the dentin surfaces. Then freshly mixed sealers were poured into the tubes and allowed to bench set for two hours and were stored at 100% humidity and 37?C for one week. With an Instron machine, the shear bond strength between the tested sealers and the dentin, in Mpa, was measured. Statistical analysis was carried out using the one-way ANOVA and Student’s t-tests. Results: Perma Evolution scored the highest mean value of sheer bond strength, being 3.343 Mpa followed by the AH plus (2.786 Mpa) and AH26 (2.149 Mpa). While the RealSeal scored the lowest mean value of sheer bond strength, which was (1.831 Mpa). ANOVA test results showed a highly statistically significant difference. Student's t test results revealed significant differences between all the compared groups, except one paired group had a non-significant difference in the shear bond strength which was between the AH plus and Perma Evolution groups (P>0.05). Conclusions: The results of this study pointed to Perma Evolution which scored the highest sheer bond strength between the tested sealers.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 11 2023
Journal Name
Applied Sciences
A Preliminary Study and Implementing Algorithm Using Finite State Automaton for Remote Identification of Drones
...Show More Authors

Electronic remote identification (ER-ID) is a new radio frequency (RF) technology that is initiated by the Federal Aviation Authorities (FAA). For security reasons, traffic control, and so on, ER-ID has been applied for drones by the FAA to enable them to transmit their unique identification and location so that unauthorized drones can be identified. The current limitation of the existing ER-ID algorithms is that the application is limited to the Wi-Fi and Bluetooth wireless controllers, which results in a maximum range of 10–20 m for Bluetooth and 50–100 m for Wi-Fi. In this study, a mathematical computing technique based on finite state automaton (FSA) is introduced to expand the range of the ER-ID RF system and reduce the ene

... Show More
View Publication
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sat Oct 01 2022
Journal Name
The Egyptian Journal Of Hospital Medicine
Impact of Vitamin D Status on Pregnant Women and Their Neonates: A Cross-Sectional Study
...Show More Authors

Preview PDF
Scopus Crossref
Publication Date
Sun Dec 27 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Analysis of Docetaxel Adverse Drug Reactions: A Retrospective Study Based on Iraqi Pharmacovigilance Center Database
...Show More Authors

Docetaxel is an effective treatment approved for many types of cancers, but its effectiveness in clinical practice can be compromised by significant occurrence of adverse drug reactions. The aim of the current study was to measure the distribution of adverse drug reactions of docetaxel reported in Iraq and to assess the causality, severity, seriousness, preventability, expectedness and outcome of these adverse reactions. A retrospective study conducted on individual case safety reports from the Iraqi Pharmacovigilance Center / Ministry of Health. The study included 118 individual case safety report containing 236 adverse drug reactions.
Most of the adverse drug reactions were related to skin and subcutaneous tissue disorders(26.7%), f

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Mar 11 2019
Journal Name
Baghdad Science Journal
A Spectral, Optical, Microscopic Study, Synthesis and Characterization of PVC Films Containing Schiff Base Complexes
...Show More Authors

In this work, synthesis of conducting polymeric films namely, PVC thin films was carried out containing Schiff base (L) with Cu2+, Cr3+, Ni2+, Co2+, in addition to inspecting the possibilities of measuring energy gap values of PVC-L-M with variety metal ions. These new polymeric films (PVC-L-M) were characterized by FTIR spectrophotometry, energy gap and surface morphology. The optical data recorded that the band gap values are influenced by the type of metals. All modified films have a red shift in optical properties in the ultraviolet region. The PVC-L-Co(II) was the lowest value of the optical band gap, 3.1 eV.

View Publication Preview PDF
Scopus (13)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Fri Nov 22 2019
Journal Name
Chalcogenide Letters
CONCENTRATION EFFECTS ON ELECTRONIC AND SPECTROSCOPIC PROPERTIES OF ZnCdS WURTZOIDS: A DENSITY FUNCTIONAL THEORY STUDY
...Show More Authors

Publication Date
Thu May 28 2020
Journal Name
Journal Of Generic Medicines: The Business Journal For The Generic Medicines Sector
Determinants of national drug products acceptance across patients, pharmacists, and manufacturers: A mixed method study
...Show More Authors
Introduction

The national pharmaceutical industry is pivotal for both the health sector and the national economy. This study aims to identify determinants of national drug products acceptance. The objectives of this study were to quantitatively measure the level of patient and community pharmacist acceptance of national drug products available in community pharmacies and to qualitatively explore the barriers facing national pharmaceutical companies and investigate the suggested solutions.

Methods

This cross-sectional study used an explanatory mixed method design. It was conducted in Baghdad, Iraq from July through October 2018. The stud

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Heliyon
Stigma towards health care providers taking care of COVID-19 patients: A multi-country study
...Show More Authors

View Publication
Scopus (33)
Crossref (27)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Al-mustansiriyah Journal Of Science
TMA and DSC study of molded and annealed polyester: a thermal expansion and crystallization evaluation
...Show More Authors

Thermomechanical analysis (TMA) and differential scanning calorimetry (DSC) are used to investigate the effect of molding and annealing of polyester on the behavior of thermal expansion and crystallization since these factors play role in the reprocessing or recycling of the polymer. The dynamic mode of the TMA provides enhanced characterization information about the polyester since it separates the transitions into reversible and irreversible signals, and also reveals the progress of the amorphous regions as the polyester loses strength with the increasing temperature approaching melting. Slow cooling after annealing brings crystallization that may be attributed to molecular chain straightening due to orientation.

View Publication Preview PDF
Publication Date
Tue Oct 07 2003
Journal Name
University Of Baghdad
A STUDY ON SOLVENT EXTRACTION OF HOLMIUM (III) WITH SUDAN BLACK B REAGENT (M.Sc. Thesis)
...Show More Authors

Preview PDF
Publication Date
Tue Apr 02 2024
Journal Name
Journal Of Engineering
Revolutionizing Depth Sensing: A Review Study of Apple LiDAR Sensor for as-built Scanning Applications
...Show More Authors

Incorporating the LiDAR sensor in the most recent Apple devices represents a substantial development in 3D mapping technology. Meanwhile, Apple's Lidar is still a new sensor. Therefore, this article reviews the potential uses of the Apple Lidar sensor in various fields, including engineering and construction, focusing on indoor and outdoor as-built 3D mapping and cultural heritage conservation. The affordable cost and shorter observation times compared to traditional surveying and other remote sensing techniques make the Apple Lidar an attractive choice among scholars and professionals. This article highlights the need for continued research on the Apple LiDAR sensor technology while discussing its specifications and limitations. A

... Show More
View Publication
Crossref (4)
Crossref