Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of the crown, closer to the lateral incisor. The linear displacement of the teeth, strains of the periodontal ligament, and stresses in PEEK wire and composite were evaluated. The data was numerically produced with color coded display by the software. Selected values were tabulated and compared among models. Results: The amount of linear displacement and strain was very low. Stresses in the wire and composite were affected by the size and position of the composite bonding spot. The safe limits were identified at 235 MPa for PEEK and 100 MPa for composite. The basic model had a von Mises stress in the PEEK wire of 122.09 MPa, and a maximum principal stress in the composite of 99.779 MPa. Both stresses were within the safe limits, which means a lower risk of failure in PEEK and composite. All other models had stresses that exceeded the safe limit of the composite. The 3 mm composite model was the only one that developed stresses in the wire more than the safe limits of PEEK. Conclusions: Within the limitations of this study, bonding PEEK wires with 4 mm bonding spots to the clinical crown center provided the best mechanical performance of the wires and spots; otherwise, the mechanical properties of the wire and composite would be affected and, therefore, might affect the retention process. Keywords: Retention, PEEK, Finite element analysis
The rapid sprawl in urban areas caused by excessive production and consumption of goods (as driven by local poor social choices) has inevitably resulted in a major burden due to environmental degradation worldwide. Unfortunately, these traditional models of urban planning fail to properly account for the intricacies that permeate a modern city and are deficient in terms of their approach as they shape themselves within an environment largely divorced from natural systems, resulting in vast mismanagement of resources, guiding cities down trajectories where growth destroys both physical and cultural landscapes. As cities suffer from increasing scarcity, we advocate for regeneration and resilience to be embedded in advanced urban design approa
... Show MoreBackground: Atherosclerosis is well known related to age and certain cardiovascular diseases. Aging is one reason of arteries function deterioration which can cause loss of compliance and plaque accumulation, this effect increases by the presence of certain diseases such as hypertension and diabetes disease. Aim: To investigate the reduction of blood supply to the brain in patients with diabetes and hypertension with age and the role of resistive index in the diagnosis of reduced blood flow. Method: Patients with both diseases diabetic and hypertension were classified according to their age to identify the progression of the disease and factors influencing the carotid artery blood flow. By using ultrasound and standard Doppler techniq
... Show MoreThis study included 50 blood samples that were collected from patients with age ranged between 35-65 years. Thirty samples were collected from patients with Type 2 Diabetes Mellitus (T2DM), while 20 blood samples were collected from healthy individuals as a control sample. The polymorphism results of TGF-β1 gene in codon 10: +869*C/T position by using amplification refractory mutation system (ARMS-PCR) showed that the T allele was suggested to have a protective effect, while C allele was associated with an increased risk of T2DM. The TT and CT were suggested to have a protective effect, while CC genotype was associated with an increased risk of T2DM. The polymorphism results of TGF-β1 gene in codon 25: +915*G/C position in samples
... Show MoreThe research study focuses on the efficient and accurate detection and determination of cobalt ions. The detection method involves the formation of brilliant green aggregates with calcium hexacyanoferrate in the presence of nitric acid. (Nagham-four sources of white snow light-emitting diodes arranged in three rows corresponding to three detectors) (The NAG-4SX3-3D Analyzer is an optical, chemical, electronic, and detection tool that receives a cumulative signal (no amplification is required). The total distance travelled is 760 mm with regard to YZ(mV) - tsec (dmm). It was selected for its precise calculation of the energy transducer profile. The linear range for measuring cobalt (II) ions is 0.05 to 20 mM. For concentrations of 5
... Show MoreBackground: Beta-thalassemia major is the most common monogenic known disorder in the Middle East, characterized by anomalies in the synthesis of the beta chains of hemoglobin resulting in variable phenotypes ranging from severe anemia to clinically asymptomatic Individuals. This study aimed to evaluate salivary flow rate and salivary IgA in β-thalassemia major patients. Since many oral and systemic conditions manifest themselves as changes in the flow and composition of saliva the dental practitioner is advised to remain up-to-date with this issue. Materials and methods: The study samples consist of (60) subjects, patients group composed of (30) patients with β –thalassemia major, age rang (5-23) years and (30) healthy locking
... Show MoreThis paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi
... Show More