Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of the crown, closer to the lateral incisor. The linear displacement of the teeth, strains of the periodontal ligament, and stresses in PEEK wire and composite were evaluated. The data was numerically produced with color coded display by the software. Selected values were tabulated and compared among models. Results: The amount of linear displacement and strain was very low. Stresses in the wire and composite were affected by the size and position of the composite bonding spot. The safe limits were identified at 235 MPa for PEEK and 100 MPa for composite. The basic model had a von Mises stress in the PEEK wire of 122.09 MPa, and a maximum principal stress in the composite of 99.779 MPa. Both stresses were within the safe limits, which means a lower risk of failure in PEEK and composite. All other models had stresses that exceeded the safe limit of the composite. The 3 mm composite model was the only one that developed stresses in the wire more than the safe limits of PEEK. Conclusions: Within the limitations of this study, bonding PEEK wires with 4 mm bonding spots to the clinical crown center provided the best mechanical performance of the wires and spots; otherwise, the mechanical properties of the wire and composite would be affected and, therefore, might affect the retention process. Keywords: Retention, PEEK, Finite element analysis
The Al-Kindy College Medical Journal (KCMJ) is an Iraqi scholarly journal published by the Al-Kindy College of Medicine, University of Baghdad. It was officially founded in 2004. It is a peer-reviewed journal, published in both online and printed forms. It has a mission to offer a publication platform that mirrors recent knowledge and findings in the field of medicine and medical sciences. It publishes various types of articles, including editorial, review article, research article, brief report, case report, and letter to editor. It accepts articles in the English language. It was biannually published till 2021 when it started to launch three issues per year. The journal is registered with numerous partners, including Iraqi Academi
... Show MoreRapid worldwide urbanization and drastic population growth have increased the demand for new road construction, which will cause a substantial amount of natural resources such as aggregates to be consumed. The use of recycled concrete aggregate could be one of the possible ways to offset the aggregate shortage problem and reduce environmental pollution. This paper reports an experimental study of unbound granular material using recycled concrete aggregate for pavement subbase construction. Five percentages of recycled concrete aggregate obtained from two different sources with an originally designed compressive strength of 20–30 MPa as well as 31–40 MPa at three particle size levels, i.e., coarse, fine, and extra fine, were test
... Show MoreBackground: It's believed that HBD-3 is involved in the tissue remodeling process of articular cartilage. Also, HBD-3 has anti-inflammatory properties. Objectives: The purpose of this study is to assay human beta-defensine-3 (HBD-3) in serum from rheumatoid arthritis (RA) patients and investigate its correlation with proinflammatory cytokines. Methods: In this case-control study, fifty-eight RA patients were aged 20–65 years, and 29 age-matched healthy subjects (HS) had no inflammatory rheumatic diseases. The disease activity score-28 joint erythrocyte sedimentation rate (DAS28-ESR) was used to measure RA activity. CRP, ACPA, HBD-3, TNF-α, and IL-1β were assessed using the enzyme-linked immunosorbent assay technique (ELISA). Res
... Show MoreThe university course timetable problem (UCTP) is typically a combinatorial optimization problem. Manually achieving a useful timetable requires many days of effort, and the results are still unsatisfactory. unsatisfactory. Various states of art methods (heuristic, meta-heuristic) are used to satisfactorily solve UCTP. However, these approaches typically represent the instance-specific solutions. The hyper-heuristic framework adequately addresses this complex problem. This research proposed Particle Swarm Optimizer-based Hyper Heuristic (HH PSO) to solve UCTP efficiently. PSO is used as a higher-level method that selects low-level heuristics (LLH) sequence which further generates an optimal solution. The proposed a
... Show More