Preferred Language
Articles
/
jbcd-2923
Comparison between the mesiodistal crown dimensions of second primary molar with stainless steel crowns from different companies
...Show More Authors

Background: Due to the variations in tooth anatomy and size among different populations, this study aimed to compare the mesiodistal width of primary second molars in Iraqi children with the mesiodistal width of stainless-steel crowns from different companies. Materials and Methods: This cross-sectional study was conducted on 220 intact maxillary and mandibular primary second molars selected from boys and girls’ Iraqi children aged 8-9 years collected from different primary schools in Baghdad city. The mesiodistal dimensions of the selected teeth and the available maxillary and mandibular stainless-steel crowns from three different companies were measured by using a 3-D scanner, and then the whole measurements were calculated using 3 shape Ortho-analyzer software program. Results: Data were analyzed statistically via SPSS V 26 software and the results showed that there’s non-significant difference between the MD measurements of second primary molars between right and left sides, and high significant difference were recorded with higher mean values for boys than girls. When comparing the same mesiodistal measurement between molars with that of stainless-steel crowns, only limited sizes of stainless steel crowns were found to be fitted to the molars of Iraqi children. Conclusion: more studies need to be applied using other stainless steel crown companies to find the relation in the mesiodistal measurement of Iraqi populations.

 

 

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Deformability of non-prismatic prestressed concrete beams with multiple openings of different configurations
...Show More Authors
Abstract<p>This work presents experimental research using draped prestressed steel strands to improve the load-carrying capacity of prestressed concrete non-prismatic beams with multiple openings of various designs. The short-term deflection of non-prismatic prestressed concrete beams (NPCBs) flexural members under static loading were used to evaluate this improvement. Six simply supported (NPCBs) beams, five beams with openings, and one solid specimen used as a reference beam were all tested as part of the experiment. All of the beams were subjected to a monotonic midpoint load test. The configuration of the opening (quadrilateral or circular), as well as the depth of the chords, were the varia</p> ... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Engineering
Serviceability of Post-fire RC Rafters with Openings of Different Sizes and Shapes
...Show More Authors

This study deals with the serviceability of reinforced concrete solid and perforated rafters with openings of different shapes and sizes based on an experimental study that includes 12 post-fire non-prismatic reinforced concrete beams (solid and perforated). Three groups were formed based on heating temperature (room temperature, 400 °C, and 700 °C), each group consisting of four rafters (solid, rafters with 6 and 8 trapezoidal openings, and rafter with eight circular openings) under static loading. A developed unified calculation technique for deflection and crack widths under static loading at the service stage has been provided, which comprises non-prismatic beams with or without opening exposed to flexure concentra

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Deformability of non-prismatic prestressed concrete beams with multiple openings of different configurations
...Show More Authors
Abstract<p>This work presents experimental research using draped prestressed steel strands to improve the load-carrying capacity of prestressed concrete non-prismatic beams with multiple openings of various designs. The short-term deflection of non-prismatic prestressed concrete beams (NPCBs) flexural members under static loading were used to evaluate this improvement. Six simply supported (NPCBs) beams, five beams with openings, and one solid specimen used as a reference beam were all tested as part of the experiment. All of the beams were subjected to a monotonic midpoint load test. The configuration of the opening (quadrilateral or circular), as well as the depth of the chords, were the varia</p> ... Show More
Crossref (2)
Crossref
Publication Date
Wed Oct 01 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Soft tissue facial profile analysis of adult Iraqis with different classes of malocclusion
...Show More Authors

Background: Complete analysis of facial profile should also include an evaluation of soft tissue morphology. Materials and Method:The sample consisted of 90 Iraqi adults (45 males and 45 females) aged 18-25 years from Baghdad city divided into 3 groups according to the ANB angle with 30 subjects in each group (15 males and 15 females) for class I, II and III. Lateral cephalometric radiograph was taken for each subject and 8 angular and 5 linear measurements were identified and determined, t-test, ANOVA and LSD test were used to compare between both genders and between different classes. Results:Showed that females had greater angular measurements and smaller linear measurements with more lip prominence than males in all classes, there was m

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 01 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Surface properties of heat treated with different durations of titanium alloy dental implants
...Show More Authors

Background: The surface properties of the titanium alloy plays a significant role in the bond of the dental implant with living bone and modification of the implant surface could enhance osseointegration. This study was aimed to investigate the effect of different durations of heat treatment on the surface properties of titanium alloy for dental implants. Materials and methods: Twenty disks of (Ti-6Al-4V) alloy were prepared. The sample was divided into four test groups to study the effect of different duration of heat treatment to the surface topography; surface chemistry, titanium oxide layer thickness, blood contact angle, & blood drop diameter of titanium alloy samples were investigated to evaluate the effect of different durations of

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Nonlinear optical properties of liquid crystal doped with different concentrations of carbon nanotubes
...Show More Authors

View Publication
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Thu Sep 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Steel Reinforcement in Concrete
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Mechanical Properties of Burnished Steel AISI 1008
...Show More Authors

Burnishing improves fatigue strength, surface hardness and decrease surface roughness of metal because this process transforms tensile residual stresses into compressive residual stresses. Roller burnishing tool is used in the present work on low carbon steel (AISI 1008) specimens. In this work, different experiments were used to study the influence of feed parameter and speed parameter in burnishing process on fatigue strength, surface roughness and surface hardness of low carbon steel (AISI 1008) specimens. The first parameter used is feed values which were (0.6, 0.8, and 1) mm at constant speed (370) rpm, while the second parameter used is speed at values (540, 800 and 1200) rpm and at constant feed (1) mm. The results of the fatigue

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 01 2018
Journal Name
J. Pharm. Sci. & Res.
Comparative study between pure bacterocin and vancomycin on biofilms of MRSA isolated from medical implants
...Show More Authors

Thirty swabes of medical implants were collected from Al-Yarmouk's hospital which were cultured on manitole agar to isolate Staphelococcus aureus . Only four samples gave positive results with this media. It was used ten types of antibiotics to test the sensitivity of this bacterium against them. All isolates of S. aureus were recorded as multidrug resistant and were considered as MRSA. One pledge alternative therapy is the utilize of certain pure bacterocin MIC (32.5 to 62.5 μg/ml) and it was compared with vancomycin (200-400 μg/ml) with average of (8 – 15) mm diameter of inhibition zones recpectively. The first reduction of biofilm formation ability has been proved in catheters when treatedby pure bacterocin. The test shows the highes

... Show More
Scopus (7)
Scopus
Publication Date
Mon Sep 30 2019
Journal Name
College Of Islamic Sciences
What agreed word and differed from        Fundamentalist terms        Between my school of speakers and jurists
...Show More Authors

In his study, the researcher highlighted the most important methods of authorship in the fundamentals of jurisprudence and speech. Fundamentalist rules and extraction and access method; they also distinct from each other that each has special divisions of the subjects of jurisprudence.

View Publication Preview PDF