Preferred Language
Articles
/
jbcd-291
An evaluation of canal transportation and centering ability at different levels of root canals prepared by self-adjusting file using computed tomography (A comparative study)
...Show More Authors

Background: The new concepts and technologies continue to change the dynamics of endodontic practices in the world. Rapid and significant changes in techniques, instrument design, and the type of metals used to manufacture endodontic instruments which have been made during the last few years in an attempt to overcome canal preparation errors. The purpose of this study is to measure and compare canal transportation and centering ability of Self Adjusting File with two rotary nickel-titanium (Ni-Ti) systems, ProTaper and BioRaCe at different levels. Material and Methods: Forty five distal roots of mandibular first molars with moderate curvature were selected using Schneider method. Roots were divided randomly into 3 groups of 15 each and were scanned using Computed Tomography (Initial scan). After canal preparation with ProTaper (group A), BioRaCe (group B), and Self Adjusting File (group C) the roots were rescanned (Final scan), the degree of canal transportation and centering ability were assessed at apical (4 mm), middle (6 mm), coronal (9 mm) sections using computed tomography. The collected data were statistically analyzed using ANOVA and Least Significant Difference tests. Results: There were no statistically significant differences among the groups at level 4 mm and level 9 mm (P ? 0.05). However, at level 6 mm there was a highly significant difference between (A) and (B) groups (P ? 0.01) and there was a significant difference between (A) and (C) groups (P ? 0.05). There were no statistically significant differences among different levels of (A) and (C) groups (P ? 0.05), while (B) group showed a highly significant difference between 4 mm and 9 mm levels and between 6 mm and 9 mm levels (P ? 0.01). Regarding canal centering ability, there was no statistically significant difference among the three groups at different levels (P ? 0.05)., while (B) group showed a significant difference between 4 mm and 9 mm levels (P ? 0.05), and a very highly significant difference between 6 mm and 9 mm levels (P ? 0.001). Conclusion: The study demonstrated that canal preparation with the three designs of Ni-Ti instruments produced canal transportation. Self Adjusting File group showed less canal transportation than ProTaper group. There was a comparable value of canal centering ability among different levels in each group except in BioRaCe group.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Aug 31 2022
Journal Name
Mathematical Modelling Of Engineering Problems
Evaluation of Al-Ishaqi Irrigation Project: A Case Study Eastern Canal of the Project
...Show More Authors

An evaluation the performance of the irrigation system for the Al-Ishaqi irrigation project for the Eastern Canal was conducted to identify management strategies that can be used to improve the operation and performance of the irrigation system. The study area is located in Salah al-Din G.0overnorate, Iraq. The field work included determining the moisture content of the soil before and after irrigation, measuring the inflow of the field to find the depth of the applied water, field monitoring, and measuring the depth of the root zone for each irrigation process. Field measurements showed that the average efficiency of water application for the two fields (A, and B) are 59.81% and 38.6%, respectively. The results of the efficiency of

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Thu Dec 05 2024
Journal Name
Shifaa
Evaluating alveolar bone thickness in upper and lower incisors from orthodontic perspective. A Cone beam computed tomography-based retrospective study
...Show More Authors

Purpose: This study aimed to assess the thickness of alveolar bone of maxillary and mandibular incisors from orthodontics perspective. Materials and Method: A total of 73 Cone beam computed tomography for Iraqi patients (47 females and 26 males) were included in this study. The selected images were captured and imported to AutoCAD database software to perform the measurement. To measure alveolar bone thickness, a reference line was drawn through the long axis of each incisor, from the incisal edge to the root apex. Then, labial and lingual/palatal perpendicular lines were drawn to the reference line at 3, 6, and 9mm apically from the cemento-enamel junction (CEJ). Results: The buccal bone is generally thinner than the lingual/palata

... Show More
View Publication
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Medico-legal Update
Cytotoxic Effect of Modified Gutta Percha by Incorporating Bioactive Glass 45S5 and Chitosan Particles As Potential Root Canal Filling
...Show More Authors

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Dental Implant Site Dimensions And Alveolar Bone Density in The Mandible Using Cone Beam Computed Tomography
...Show More Authors

Background: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample in

... Show More
View Publication
Crossref
Publication Date
Fri Dec 06 2019
Journal Name
Karbala International Journal Of Modern Science
Stereo Photogrammetry vs Computed Tomography for 3D Medical Measurements
...Show More Authors

View Publication
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Fri Jan 31 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
A comparative study to evaluate the effect of ultrasonic agitation on push-out bond strength of three root-end filling materials: An in vitro study
...Show More Authors

Aim: To evaluate the effect of ultrasonic agitation for retrograde biodceramic root repair, MTA and biodentine filling materials on push-out bond strength to dentine walls. Materials and Methods: Ninety extracted human teeth with single straight roots were selected randomly. After disinfection and cleaning, the coronal portions were sectioned to standardize the root canal length at 15mm. following root canal shaping, obturation and apical roots resection, retrograde cavities were prepared. Teeth were categorized depending on the filling material used into three groups, 30 teeth each. Group A filled with bioceramic root repair material, B with MTA and C with Biodentine material. These groups were divided in to three subgroup (n= 10). Subgrou

... Show More
Scopus (1)
Scopus
Publication Date
Thu Sep 25 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of Corrosion Pits in Esthetic Coated Stainless Steel Orthodontic Archwires in Dry and Wet Environment at Different Intervals (An In Vitro Study)
...Show More Authors

Background: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chl

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 15 2021
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of The Antifungal Activity of Nasturtium officinale (watercress) Oil with Calcium Hydroxide against Candida Albicans Isolated from Root Canal
...Show More Authors

Background: The interest in herbal extracts as antimicrobial agents has increased over the past few years in endodontic therapy. Nasturtium officinale (watercress) is a promising plant with great medicinal values. This study aimed to investigate the antifungal activity of watercress oil in combination with calcium hydroxide against Candida albicans as intracanal medicament. Materials and Methods: Candida albicans was isolated from patients with necrotic root canal or failed root canal treatment. The sensitivity of Candida albicans to different concentrations of watercress oil extract was determined by using the agar well diffusion method in comparison with calcium hydroxide paste. The agar plate method was used to determine the minimum fung

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (6)
Scopus Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (13)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Sat Jun 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
The accuracy of cone-beam computed tomography in the evaluation of boney support of teeth among patients with a unilateral cleft of lip and palate among IraqiPopulation
...Show More Authors

Background: To evaluate the bony supports of the teeth adjacent to the area of cleft in patient with unilateral cleft lip and palate and to compare these measurements with the measurements of the same teeth in non-cleft side by using CBCT. Materials and methods: The CBCT scans of 30 patients having cleft lip( unilateral) and palate(unilateral), were analyzed and the measurements of the alveolar bony support for teeth that are adjacent to the cleft area were measured with those teeth located on opposite side (non- clef) side. For each tooth, the measurements will taken for the distance between the( cementoenamel junction) (CEJ) and the bony crest (AC) at the( buccal area) was measured and the thickness of the buccal plate At zero, one, tw

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Crossref