Preferred Language
Articles
/
jbcd-291
An evaluation of canal transportation and centering ability at different levels of root canals prepared by self-adjusting file using computed tomography (A comparative study)
...Show More Authors

Background: The new concepts and technologies continue to change the dynamics of endodontic practices in the world. Rapid and significant changes in techniques, instrument design, and the type of metals used to manufacture endodontic instruments which have been made during the last few years in an attempt to overcome canal preparation errors. The purpose of this study is to measure and compare canal transportation and centering ability of Self Adjusting File with two rotary nickel-titanium (Ni-Ti) systems, ProTaper and BioRaCe at different levels. Material and Methods: Forty five distal roots of mandibular first molars with moderate curvature were selected using Schneider method. Roots were divided randomly into 3 groups of 15 each and were scanned using Computed Tomography (Initial scan). After canal preparation with ProTaper (group A), BioRaCe (group B), and Self Adjusting File (group C) the roots were rescanned (Final scan), the degree of canal transportation and centering ability were assessed at apical (4 mm), middle (6 mm), coronal (9 mm) sections using computed tomography. The collected data were statistically analyzed using ANOVA and Least Significant Difference tests. Results: There were no statistically significant differences among the groups at level 4 mm and level 9 mm (P ? 0.05). However, at level 6 mm there was a highly significant difference between (A) and (B) groups (P ? 0.01) and there was a significant difference between (A) and (C) groups (P ? 0.05). There were no statistically significant differences among different levels of (A) and (C) groups (P ? 0.05), while (B) group showed a highly significant difference between 4 mm and 9 mm levels and between 6 mm and 9 mm levels (P ? 0.01). Regarding canal centering ability, there was no statistically significant difference among the three groups at different levels (P ? 0.05)., while (B) group showed a significant difference between 4 mm and 9 mm levels (P ? 0.05), and a very highly significant difference between 6 mm and 9 mm levels (P ? 0.001). Conclusion: The study demonstrated that canal preparation with the three designs of Ni-Ti instruments produced canal transportation. Self Adjusting File group showed less canal transportation than ProTaper group. There was a comparable value of canal centering ability among different levels in each group except in BioRaCe group.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Entry cost based on activity-based cost specifications and comparative study
...Show More Authors

Several recent approaches focused on the developing of traditional systems to measure the costs to meet the new environmental requirements, including Attributes Based Costing (ABCII). It is method of accounting is based on measuring the costs according to the Attributes that the product is designed on this basis and according to achievement levels of all the Attribute of the product attributes. This research provides the knowledge foundations of this approach and its role in the market-oriented compared to the Activity based costing as shown in steps to be followed to apply for this Approach. The research problem in the attempt to reach the most accurate Approach in the measurement of the cost of products from th

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Comparative Study for Organic and Inorganic Draw Solutions in Forward Osmosis
...Show More Authors

The present work aims to study forward osmosis process using different kinds of draw solutions and membranes. Three types of draw solutions (sodium chloride, sodium formate, and sodium acetate) were used in forward osmosis process to evaluate their effectiveness with respect to water flux and reverse salt flux. Experiments conducted in a laboratory-scale forward osmosis (FO) unit in cross flow flat sheet membrane cell.  Three types of membranes (Thin film composite (TFC), Cellulose acetate (CA), and Cellulose triacetate (CTA)) were used to determine the water flux under osmotic pressure as a driving force. The effect of temperature, draw solution concentration, feed and draw solution flow rate, and membrane types, were studied with

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Fri Sep 30 2022
Journal Name
Journal Of The Iraqi University
Exclusion optimal portfolio from outlier by using fuzzy c-means clustering - analytical research at the Iraqi Stock Exchange
...Show More Authors

This research aims to solve the problem of selection using clustering algorithm, in this research optimal portfolio is formation using the single index model, and the real data are consisting from the stocks Iraqi Stock Exchange in the period 1/1/2007 to 31/12/2019. because the data series have missing values ,we used the two-stage missing value compensation method, the knowledge gap was inability the portfolio models to reduce The estimation error , inaccuracy of the cut-off rate and the Treynor ratio combine stocks into the portfolio that caused to decline in their performance, all these problems required employing clustering technic to data mining and regrouping it within clusters with similar characteristics to outperform the portfolio

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2013
Journal Name
Journal Of Engineering
Design and Implementation of a Generalized N-Digit Binary-To-Decimal Converter on an FPGA Seven-Segment Display Using Verilog Hdl Design and Implementation of a Generalized N-Digit Binary-To-Decimal Converter on an FPGA Seven-Segment Display Using Verilog Hdl
...Show More Authors

It is often needed to have circuits that can display the decimal representation of a binary number and specifically in this paper on a 7-segment display. In this paper a circuit that can display the decimal equivalent of an n-bit binary number is designed and it’s behavior is described using Verilog Hardware Descriptive Language (HDL). This HDL program is then used to configure an FPGA to implement the designed circuit.

Publication Date
Tue Aug 15 2023
Journal Name
Journal Of Current Researches On Social Sciences
An Examination of Discourse Investigation of Fallacies in Religious Texts: Islam as a Case Study
...Show More Authors

BN RASHİD, 2023

View Publication
Publication Date
Tue Sep 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Conservation Nursing Strategies (*)An exploratory study of a sample of managers in Baghdad health departments
...Show More Authors

The deficiency in the nurse staff  in the health organizations consider an important problem that must be studied and solved basically , not only because it affect on the health organization and it's strategic goals , but also it affect the human being and it's health which can't be substituted with anything or delayed in it's treatment ,This research aims to  necessary for health organizations to strategically help in maintaining the nurse staff and to keep that in it's strategic orientation and it's mission , moreover , the health organizations must study the reality of the nurse in the health organizations and know the causes beyond leaving the  nurse staff  the nurse job , and then remove

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 08 2025
Journal Name
Journal Of Baghdad College Of Dentistry
X-ray diffraction and biocompatibility of glass ionomer cement reinforced by different ratios of synthetic hydroxyapatite
...Show More Authors

Background: This study was done to assist X-ray diffraction and biocompatability of glass ionomer cement reinforced by different ratios of Hydroxyapatite. Materials and Methods: The powder of glass ionomer cement reinforced by different ratios of Hydroxyapatite were used to get X-ray diffraction pattern by X-ray diffraction machine, While for biocompatibility test, A polyethylene tubes containing glass ionomer cement reinforced by different ratios of Hydroxyapatite were implanted on the dorsal submucosal site of Rabbit's tissues and histological slide were prepared for histopathological study. Results: X-ray diffraction test showed that all elements of glass ionomer cement reinforced by different ratios of Hydroxyapatite were react with eac

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Maxillofacial Surgery
The use of screw retained hybrid arch bar for maxillomandibular fixation in the treatment of mandibular fractures: A comparative study
...Show More Authors

Introduction: The use of screw-retained hybrid arch bars (HABs) is a relatively recent development in the treatment of mandibular fractures. The purpose of this study is to compare the clinical outcome between HAB and the conventional Erich arch bar (EAB) in the closed treatment of mandibular fractures. Materials and methods: This study included 18 patients who were treated for mandibular fractures with maxillomandibular fixation (MMF), patients were randomly assigned into a control group (n = 10) in which EAB was used and study group (n = 8) in which HAB was used. The outcome variables were time required for application and removal, gingival inflammation scores, postoperative complications, and incidence of wire-stick injury or gloves perf

... Show More
View Publication
Scopus (6)
Crossref (8)
Scopus Crossref
Publication Date
Sun Dec 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of platelet rich-fibrin on alveolar osteitis incidence following surgical removal of impacted mandibular third molars: A comparative study
...Show More Authors

Background: Postoperative morbidity after extraction of the impacted mandibular third molar (IMTM) is inevitable. One of the most common postoperative complication is alveolar osteitis (AO) which is a painful non healed socket. Many researches were attempted to prevent the occurrence of AO by introducing and applying a new materials inside the extraction socket. Platelet rich fibrin (PRF) is a biological complex fibrin matrix where autologous platelets and leucocytes are present, used to enhance tissue healing process and reduce the early adverse effects of the inflammation. Aims: To evaluate the effect of PRF on the incidence of AO. Also to assess PRF effect on pain, swelling, and trismus following the surgical removal of IMTM and

... Show More
View Publication
Scopus (10)
Crossref (5)
Scopus Crossref
Publication Date
Sun Dec 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of platelet rich-fibrin on alveolar osteitis incidence following surgical removal of impacted mandibular third molars: A comparative study
...Show More Authors

Background: Postoperative morbidity after extraction of the impacted mandibular third molar (IMTM) is inevitable. One of the most common postoperative complication is alveolar osteitis (AO) which is a painful non healed socket. Many researches were attempted to prevent the occurrence of AO by introducing and applying a new materials inside the extraction socket. Platelet rich fibrin (PRF) is a biological complex fibrin matrix where autologous platelets and leucocytes are present, used to enhance tissue healing process and reduce the early adverse effects of the inflammation. Aims: To evaluate the effect of PRF on the incidence of AO. Also to assess PRF effect on pain, swelling, and trismus following the surgical removal of IMTM and compa

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (5)
Scopus Crossref