Preferred Language
Articles
/
jbcd-291
An evaluation of canal transportation and centering ability at different levels of root canals prepared by self-adjusting file using computed tomography (A comparative study)
...Show More Authors

Background: The new concepts and technologies continue to change the dynamics of endodontic practices in the world. Rapid and significant changes in techniques, instrument design, and the type of metals used to manufacture endodontic instruments which have been made during the last few years in an attempt to overcome canal preparation errors. The purpose of this study is to measure and compare canal transportation and centering ability of Self Adjusting File with two rotary nickel-titanium (Ni-Ti) systems, ProTaper and BioRaCe at different levels. Material and Methods: Forty five distal roots of mandibular first molars with moderate curvature were selected using Schneider method. Roots were divided randomly into 3 groups of 15 each and were scanned using Computed Tomography (Initial scan). After canal preparation with ProTaper (group A), BioRaCe (group B), and Self Adjusting File (group C) the roots were rescanned (Final scan), the degree of canal transportation and centering ability were assessed at apical (4 mm), middle (6 mm), coronal (9 mm) sections using computed tomography. The collected data were statistically analyzed using ANOVA and Least Significant Difference tests. Results: There were no statistically significant differences among the groups at level 4 mm and level 9 mm (P ? 0.05). However, at level 6 mm there was a highly significant difference between (A) and (B) groups (P ? 0.01) and there was a significant difference between (A) and (C) groups (P ? 0.05). There were no statistically significant differences among different levels of (A) and (C) groups (P ? 0.05), while (B) group showed a highly significant difference between 4 mm and 9 mm levels and between 6 mm and 9 mm levels (P ? 0.01). Regarding canal centering ability, there was no statistically significant difference among the three groups at different levels (P ? 0.05)., while (B) group showed a significant difference between 4 mm and 9 mm levels (P ? 0.05), and a very highly significant difference between 6 mm and 9 mm levels (P ? 0.001). Conclusion: The study demonstrated that canal preparation with the three designs of Ni-Ti instruments produced canal transportation. Self Adjusting File group showed less canal transportation than ProTaper group. There was a comparable value of canal centering ability among different levels in each group except in BioRaCe group.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 13 2022
Journal Name
Emergent Materials
Spectroscopic characteristics of highly pure metal oxide nanostructures prepared by DC reactive magnetron sputtering technique
...Show More Authors

In this work, metal oxide nanostructures, mainly copper oxide (CuO), nickel oxide (NiO), titanium dioxide (TiO2), and multilayer structure, were synthesized by the DC reactive magnetron sputtering technique. The effect of deposition time on the spectroscopic characteristics, as well as on the nanoparticle size, was determined. A long deposition time allows more metal atoms sputtered from the target to bond to oxygen atoms and form CuO, NiO, or TiO2 molecules deposited as thin films on glass substrates. The structural characteristics of the final samples showed high structural purity as no other compounds than CuO, NiO, and TiO2 were found in the final samples. Also, the prepared multilayer structures did not show new compounds other than th

... Show More
View Publication
Scopus (25)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Wed Nov 30 2022
Journal Name
Desalination And Water Treatment
Removal of amoxicillin from wastewater by adsorption onto activated carbon prepared from sunflower seed hulls
...Show More Authors

In this study, the potential of adsorption of amoxicillin antibiotic (AMOX) from aqueous solutions using prepared activated carbon (AC) was studied. The used AC was prepared from an inexpensive and available precursor (sunflower seed hulls (SSH)) and activated by potassium hydroxide (KOH). The prepared AC was examined for its ability to remove AMOX from aqueous contaminated solutions and characterized with the aid of N2 -adsorption/desorption isotherm Brunauer–Emmett– Teller, scanning electron microscopy, energy-dispersive X-ray spectroscopy and Fourier-transform infrared. Zeta potential of the prepared activated carbon from sunflower seed hulls (SSHAC) were studied in relation to AMOX adsorption. The physical and chemical propert

... Show More
View Publication Preview PDF
Crossref (6)
Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
International Journal For Light And Electron Optics
Optical properties of Ag-doped nickel oxide thin films prepared by pulsed-laser deposition technique
...Show More Authors

In this work, pure and Ag-doped nickel oxide (NiO) thin films were deposited on glass substrates with different dopant concentrations (0.1, 0.2, 0.3 and 0.4 wt.%) by pulsed-laser deposition (PLD) technique at room temperature. These films were annealed at temperature of 450 °C. The structural and optical properties of the prepared thin films were studied. It was found that annealing process has lead to increase the transmittance of the deposited films. Also, the transmittance was found to increase with doping concentration of silver in the deposited NiO films. The optical energy gap was decreased from 3.5 to 3.2 eV as the doping concentration was increased to 0.4 %.

View Publication
Scopus (30)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Wed Dec 02 2020
Journal Name
Iraqi Journal Of Applied Physics
Characterization of Multilayer Highly-Pure Metal Oxide Structures Prepared by DC Reactive Magnetron Sputtering Technique
...Show More Authors

In this work, multilayer nanostructures were prepared from two metal oxide thin films by dc reactive magnetron sputtering technique. These metal oxide were nickel oxide (NiO) and titanium dioxide (TiO2). The prepared nanostructures showed high structural purity as confirmed by the spectroscopic and structural characterization tests, mainly FTIR, XRD and EDX. This feature may be attributed to the fine control of operation parameters of dc reactive magnetron sputtering system as well as the preparation conditions using the same system. The nanostructures prepared in this work can be successfully used for the fabrication of nanodevices for photonics and optoelectronics requiring highly-pure nanomaterials.

View Publication Preview PDF
Publication Date
Sun May 01 2016
Journal Name
Journal Of Multidisciplinary Engineering Science Studies
The Thickness Effects Characterization Properties Of Copper Oxide Thin Films Prepared By Thermal Evaporation Technique
...Show More Authors

In This paper, CuO thin films having different thickness (250, 300 , 350 and 400) nm were deposited on glass substrates by thermal vacuum evaporator. The thermal oxidation of this evaporated film was done in heated glass at temperature (300 in air at one hour. The study of X-ray diffraction investigated all the exhibit polycrystalline nature with monoclinic crystal structure include uniformly grains. Thin film’s internal structure topographical and optical properties. Furthermore, the crystallization directions of CuO (35.54 , 38.70 ) can be clearly observed through an X-ray diffraction analysis XRD, Atomic Force Microscope AFM (topographic image) showed that the surface Characteristics , thin films crystals grew with increases in either

... Show More
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Annealing Effect on Some Optical Properties of Cr2O3 Thin Films Prepared by Spray Pyrolysis Technique
...Show More Authors

Cr2O3 thin films have been prepared by spray pyrolysis on a glass substrate. Absorbance and transmittance spectra were recorded in the wavelength range (300-900) nm before and after annealing. The effects of annealing temperature on absorption coefficient, refractive index, extinction coefficient, real and imaginary parts of dielectric constant and optical conductivity were expected. It was found that all these parameters increase as the annealing temperature increased to 550°C.

View Publication Preview PDF
Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Iraqi Journal Of Physics
Employment of Silicon Nitride Films Prepared by DC Reactive Sputtering Technique for Ion Release Applications
...Show More Authors

In this work, silicon nitride (Si3N4) thin films were deposited on metallic substrates (aluminium and titanium sheets) by the DC reactive sputtering technique using two different silicon targets (n-type and p-type Si wafers) as well as two Ar:N2 gas mixing ratios (50:50 and 70:30). The electrical conductivity of the metallic (aluminium and titanium) substrates was measured before and after the deposition of silicon nitride thin films on both surfaces of the substrates. The results obtained from this work showed that the deposited films, in general, reduced the electrical conductivity of the substrates, and the thin films prepared from n-type silicon targets using a 50:50 mixing ratio and deposited on both

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Nov 02 2023
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Appraising the Role of Pharmacists in Medication Reconciliation at Hospital Discharge: A Field-Based Study
...Show More Authors

Objective: To measure the effect of the pharmacist-led medication reconciliation service before hospital discharge on preventing potential medication errors. Methods: This behavioral interventional study took place in a public teaching hospital in Iraq between December 2022 and January 2023. It included inpatients who were taking four or more medications upon discharge from the internal medicine ward and the cardiac care unit. The researcher provided the patients with a medication reconciliation form and reconciliation form (including medication regimen and pharmacist instructions) before discharging them home. Any discrepancies between the patients’ understanding and the actual medication recommendations prescribed by the physici

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Study of the Electric Quadrupole Moments for some Scandium Isotopes Using Shell Model Calculations with Different Interactions
...Show More Authors

The electric quadrupole moments for some scandium isotopes (41, 43, 44, 45, 46, 47Sc) have been calculated using the shell model in the proton-neutron formalism. Excitations out of major shell model space were taken into account through a microscopic theory which is called core polarization effectives. The set of effective charges adopted in the theoretical calculations emerging about the core polarization effect. NushellX@MSU code was used to calculate one body density matrix (OBDM). The simple harmonic oscillator potential has been used to generate the single particle matrix elements. Our theoretical calculations for the quadrupole moments used the two types of effective interactions to obtain the best interaction compared with the exp

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Evaluation of health and safety management systemAccording to international standards OHSAS 18001: 2007A case study at Al-Mamoun Factory / General Company for vegetable oil industry
...Show More Authors

This research aims to knowledge of the scope of applying the international specification of which is regarded to occupational health and safety management system (OHSAS 18001) second edition for year 2007 by The AL-Mammon Factory / The General Company For Vegetable Oils Industry in order to diagnosis the gap between specification requirements and reality by using the checklist made based upon the items of the specification, after translating the English copy into Arabic. The results of the research and analysis that occupational health and safety management system in comparison to the specification requirements in all of its main items, which was (%22.26) applied and documented partly, this refer to the existence of great gap (%7

... Show More
View Publication Preview PDF
Crossref