Preferred Language
Articles
/
jbcd-2912
Effect of ageing media on shear bond strength of metal orthodontic brackets bonded with different adhesive systems (A comparative in-vitro study)
...Show More Authors

Background: The aim of this study was to evaluate the shear bond strength (SBS) and adhesive remnant index (ARI) of different orthodontic adhesive systems after exposure to aging media (water storage and acid challenge). Materials and methods: Eighty human upper premolar teeth were extracted for orthodontic purposes and randomly divided into two groups (40 teeth each): the first group in which the bonded teeth were stored in distilled water for 30 days at 37°C, and the second group in which the bonded teeth were subjected to acid challenge. Each group was further subdivided into four subgroups (10 teeth each) according to the type of adhesive system that would be bonded to metal brackets: either non-fluoride releasing adhesive (NFRA), fluoride releasing adhesive (FRA), Fluoride releasing bond with self-etching primer (FRBSP), or powder and liquid orthodontic fluoride releasing adhesive (PLFRA). After 30 days of water storage and acid challenge ageing procedures, the SBS was determined using Instron testing machine with a crosshead speed of 1 mm/min. The ARI was assessed using a stereomicroscope with 10 X magnification. Result: The SBS testing revealed significant differences (p< 0.05) among the four tested adhesive systems in water storage and acid challenge groups using ANOVA F-test. In both groups, the NFRA subgroup exhibited the highest mean SBS value, followed by FRASP, then FRA subgroups, while the PLFRA subgroup had the lowest value of mean SBS. The independent t-test showed non-significant differences in mean SBS values between water storage and acid challenge groups. In respect to the ARI analysis, the Chi-square test showed significant differences among the tested adhesive systems. Conclusion: The shear bond strength of the fluoride releasing adhesive system was less than that of the non-fluoride releasing adhesive system, but still above the clinically acceptable range.

 

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed May 24 2023
Journal Name
2023 9th International Conference On Information Technology Trends (itt)
A Comparative Study of Unauthorized Drone Detection Techniques
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the accuracy of a fifth generation apex locator (in vitro study)
...Show More Authors

Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t

... Show More
Preview PDF
Publication Date
Thu Feb 17 2022
Journal Name
Teikyo Medical Journal
Study the Effect of different doses of Rapamycin on the liver development in the Swiss Albino Mice Embryos
...Show More Authors

The current study, which extended from February 2020 to June 2021 at the University of Thi- Qar\ College of Education for Pure Sciences, aimed to follow the changes in external morphological features at different Embryonic Developmental stages in pregnant mice treated with different doses of Rapamycin (Rapa). Use In this study, 32 pregnant mice were divided randomly into four groups, each of which had eight pregnant mice. Each group received different dose of Rapa via intraperitoneally injection at different gestation days until the end of the specified periods, whereas the control group received a DMSO. Mice were administered under the same circumstances and dosages were determined based on body weight, as specified in pharmaceutical const

... Show More
Publication Date
Fri Jul 01 2016
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
STUDY THE EFFECT OF DIFFERENT TYPES OF STRESS ON SOME BLOOD CONSTITUENTS AND PLASMA BIOCHAMICALS IN MALE RATS
...Show More Authors

    The objective of this work was to determine and compare the physiological changes in some: blood components (packed cell volume and hemoglobin) and plasma biochemical parameters (glucose, total protein, albumin, cholesterol and triglycerides) under 3 day of different types of stress: water deprivation, starvation, overcrowding and handling stress. Twenty five male Wister rats weighted 100-120 gm, were divided randomly into five groups: control, water deprivation, starvation, overcrowding and handling stress. On the third day of stress the animals anesthetized for blood collection; the results of blood component revealed a significant increase in PCV and a significant decrease in Hb of water deprivation group and starva

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2024
Journal Name
Journal Of Language Studies
Translation Challenges in Children's Literature: A Comparative Study of Story Narratives
...Show More Authors

This paper presents the intricate issues and strategies related to the translation of children's books, and it particularly focuses on the comparative analysis of "The Tale of Peter Rabbit" by Beatrix Potter and "Le Petit Prince" (The Little Prince) by Antoine de Saint-Exupéry. The study finds that the typical problems in translation are, idiomatic expressions, cultural reference, and the voice preservation, along side-sheet-specific challenges which each of the text faces. The translator of Potter's work should have skills of transposing all culturally oriented peculiarities of the UK land to the international audience to keep it accessible. On the contrary, "Le Petit Prince" translation will be the process of capturing the abstra

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Dec 17 2017
Journal Name
Al-khwarizmi Engineering Journal
Study the Effect of Different Reinforcements on the Damping Properties of the Polymer Matrix Composite
...Show More Authors

In this research, damping properties for composite materials were evaluated using logarithmic decrement method to study the effect of reinforcements on the damping ratio of the epoxy matrix. Three stages of composites were prepared in this research. The first stage included preparing binary blends of epoxy (EP) and different weight percentages of polysulfide rubber (PSR) (0%, 2.5%, 5%, 7.5% and 10%). It was found that the weight percentage 5% of polysulfide was the best percentage, which gives the best mechanical properties for the blend matrix. The advantage of this blend matrix is that; it mediates between the brittle properties of epoxy and the flexible properties of a blend matrix with the highest percentage of PSR. The second stage

... Show More
View Publication Preview PDF
Publication Date
Wed May 01 2024
Journal Name
Journal Of Orthodontic Science
Keeping the teeth in line: Exploring the necessity of bonded retainers in orthodontics: A narrative review
...Show More Authors

In most recent studies, long-term retention after orthodontic treatment has been hypothesized that may be necessary to maintain the stability of the dentition and avoid post-treatment changes. The bonded fixed retainer is characterized by its clinical effectiveness, patient acceptance, and lack of patient complaints as compared with a removable retainer. An electronic database (such as PubMed, PubMed Central, Web of Science, Science Direct, Cochrane Library, Scopus, and ResearchGate) has been collected using specific keywords. Of the 152 articles, only randomized clinical trials that investigated different types of fixed retainers or compared fixed with removable retainers were illustrated in tables and included in this review. The

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Validity of Digital and Rapid Prototyped Orthodontic Study Models
...Show More Authors

Background: The integration of modern computer-aided design and manufacturing technologies in diagnosis, treatment planning, and appliance construction is changing the way in which orthodontic treatment is provided to patients. The aim of this study is to assess the validity of digital and rapid prototyped orthodontic study models as compared to their original stone models. Materials and methods: The sample of the study consisted of 30 study models with well-aligned, Angle Class I malocclusion. The models were digitized with desktop scanner to create digital models. Digital files were then converted to plastic physical casts using prototyping machine, which utilizes the fused deposition modeling technology. Polylactic acid polymer was chose

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of olive oil as a separating medium and its effect on some physical properties of processed acrylic resin denture base (A comparative study). Part one
...Show More Authors

Back ground: During acrylic resin processing, the mold must be separated from the surface of the gypsum to prevent liquid resin from penetrating into the gypsum, and water from the gypsum seeping into the acrylic resin. For many years, tin foil was the most acceptable separating medium, and because it's difficult to apply, a tin-foil substitute is used. In this study, olive oil is used as an alternative to tin foil separating medium for first time, so the aim of the study was to evaluate its effect as a separating medium on some physical properties such as (surface roughness, water sorption and solubility) of acrylic resins denture base comparing it with those processed using tin-foil and tin foil substitute such as (cold mold seal) separat

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Marginal Discrepancy and Fracture Resistance of CAD/CAM Ceramill Sintron Metal Copings with Different Porcelain Materials
...Show More Authors

Background: This study was performed to compare the marginal fit changes and facture resistance of metal ceramic crowns constructed from Ceramill Sintron metal coping veneered with three different porcelain veneering materials (Vita Master Koromikos VMK, Willi Geller Creation CC and GC initial MC), also to evaluate the influence of thermocycling on load at fracture. Materials and Methods: Master brass die was scanned ,then metal coping was designed and milled from Ceramill Sintron blank to get 60 metal copings, then divided randomly into three groups(20 sample), then veneered with porcelain: VITA, Creation or GC. The marginal gaps were measured before and after porcelain veneering then marginal fit changes was calculated. Fracture resist

... Show More
View Publication Preview PDF
Crossref