Background: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), the effect of post types ( Manually Milled Zirconia post, Prefabricated Fiber post, prefabricated Zirconia post) and the type of cement used (GIC, self-adhesive resin cement) on the bond strength between the posts and root dentin by using push-out test. Material and methods: Forty eight mandibular premolars extracted for orthodontic reasons (single rooted) were instrumented with ProTaper system (hand use) and obturated with gutta percha for ProTaper using AH26® root canal sealer following the manufacturer instructions. After 24 hours, post space was prepared using Zirix and Glassix drills no.3 creating 8 mm depth post space. The prepared samples were randomly divided into three main groups (16 samples each) according to the type of post used (Group A. Manually Milled Zirconia post, Group B. Prefabricated Fiber post and Group C. Prefabricated Zirconia post) .each group was subdivided into two subgroups (each subgroup contains 8 samples) according to the type of cement used (subgroup A1.Manually Milled Zirconia post cemented with GIC, subgroup A2.Manually Milled Zirconia post cemented with Speed cem),( subgroup B1.Prefabricated Fiber post cemented with GIC, Group B2. Prefabricated Fiber post cemented with Speed cem) and (subgroup C1.Prefabricated Zirconia post cemented with GIC, subgroup C2. Prefabricated Zirconia post cemented with Speed cem), after cementation and incubation for 24hrs, at 37°c and 100% humidity. Each root was sectioned horizontally into 3 slices (2 mm in thickness) representing the coronal, middle and apical regions of the post space. Push out bond strength test was performed and measured using a universal testing machine (Tinius-Olsen) at across head speed of 0.5 mm/min. Results: The results showed that regarding the root region, the bond strength values increased significantly from apical to coronal region for all types of posts in both tested cements. For the effect of post type, the manually Milled Zirconia post cemented with the self-cured resin cement (Speed cem) showed higher bond strength values. For type of cement, the self-adhesive resin cement (Speed cem) showed higher bond strength values. Conclusions: the retention of post restoration was affected by root region, type of post and type of cement used.
In solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational
... Show MoreKlebsiella pneumoniae has been found in the urinary tract of some bladder cancer patients. Bacterial presence within tumor tissue may affect the tumor-microenvironment and consequently influence cancer behavior, development, and treatment response. This study investigated mesenchymal and stemness transdifferentiation of bladder cancer cell line due to environmental stress of K. pneumoniae. Cultures of urothelial bladder cancer cell line (T24) were infected with K. pneumoniae with different multiplicity of infection (MOI) for two and four days. Transdifferentiation-associated features were morphologically assessed.
Moreover, transdifferentiation markers were estimated using Q-PCR and immunohistoc
... Show MoreBackground: Indeterminate colitis (IC), a term
originated by pathologists to characterize confounding
histopathlogic appearance of resected mucosa, has
become catch phrase for cases in which diagnostic
criteria at all levels elude classification as Crohn's
disease (CD) or ulcerative colitis (UC).
OBJECTIVES: evaluate the prevalence of pANCA
expression in the sera and its isotypes.
Patients and methods: PATIENTS GROUP
consisted of 60 patients (40 males and 20 females)
with indeterminate colitis and their age range was (19-
84 years). CONTROL GROUP consisted of 30 (15
males and 15 females) healthy volunteers and their
age range was (20- 66 years).
Antineutrophil cytoplasmic ( pANCA and cANCA)
te