Background: Polymer surfaces usually present problems in bonding and finishing due to their low hydrophilicity. The aim of this study is to investigate the effect of plasma treatment with the use of two types of gases (oxygen and argon) on surface roughness, and chemical surface properties of acrylic resin denture base polymer material. Materials and Methods: Three heat cured acrylic resin specimens of (2*8*30 mm) dimensions were prepared for each test carried out in this study. Two tests were conducted, surface roughness test and chemical surface analysis test. Results: Application of plasma treatment increased surface roughness for both oxygen and argon plasma treated acrylic resin specimen groups compared with control untreated group, with a highly significant difference (P <0.01) among groups. FTIR chemical analysis for oxygen plasma treated acrylic resin specimen group showed a spectrum with a broad peak, which represents the hydroxyl group (-OH). This was an important chemical change that increased the hydrophilicity as compared with FTIR spectrums of control and argon plasma treated acrylic resin groups which exhibited relatively the same peaks with mild chemical changes. Conclusion: Application of oxygen and argon plasma treatment represents an effective surface treatment method for increasing the surface roughness of acrylic resin denture base polymer material. Oxygen plasma treatment can activate the treated surface towards further chemical reactions, and increase the hydrophilicity of the acrylic resin denture base polymer material. Key words: Acrylic resin polymer, plasma treatment, surface roughness, FTIR analysis.
In this work, diamond-like carbon (DLC) thin films were prepared from Cyclohexane. Thin films were deposited on quartz substrate by atmospheric pressure Argon plasma jet system. The plasma jet system was applying high voltage sinusoidal waves of frequency 28 kHz and potential difference of 7.5kV peak to peak across the electrodes. The effect of annealing at 400, 500 and 600 °C under vacuum for two hours on optical properties and structural properties of the DLC thin films were investigated. This effect was clarified by X-ray diffraction (XRD), FTIR, UV-Visible absorption, Scanning Electron Microscopy (SEM) and Raman Spectroscopy. The X-ray diffraction patterns for the annealing DLC thin films show two broad peaks at 2θ, 26.62° and 51.58
... Show MoreComputer modeling has been used to investing the Coulomb coupling parameter ?. The effects of the structure parameter K, grain charge Z, plasma density N, temperature dust grain Td, on the Coulomb coupling parameter had been studied. It was seen that the ? was increasing with increasing Z and N, and decrease with increasing K and T. Also the critical value of ? that the phase transfer of the plasma state from liquid to solid was studied.
Pregnancy- including hypertension(PIH), also known as preeclampsia, is one of the major causes of maternal and fetal death. This study was carried out on 30 pregnant women with preeclampsia and 30 healthy pregnant women as control ranging in age mean ±SD (28.84±3.55) years , BMI (76.80±9.78) Kg/m2 and gestation age(30.82±0.75)week. The aim of this research was studied the plasma Metanephrine level and other biochemical parameters such as Hemoglobin(Hb), serum Protein, S. Albumin, Globulin, Albumin/Globulin ratio (Alb/Glu. ratio), S.Glutamate Pyruvate aminotransferase (GPT), S.Glutamate Oxaloacetate aminotransferase(GOT). The obtained results have been compared with 30 healthy pregnant women as control group. The result showed
... Show MoreDielectric barrier discharges (DBD) can be described as the presence of contact with the discharge of one or more insulating layers located between two cylindrical or flat electrodes connected to an AC/pulse dc power supply. In this work, the properties of the plasma generated by dielectric barrier discharge (DBD) system without and with a glass insulator were studied. The plasma was generated at a constant voltage of 4 kV and fixed distance between the electrodes of 5 mm, and with a variable flow rate of argon gas (0.5, 1, 1.5, 2 and 2.5) L/min. The emission spectra of the DBD plasmas at different flow rates of argon gas have been recorded. Boltzmann plot method was used to calculate the plasma electron temperature (Te), and Stark broadeni
... Show MoreIn this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in
... Show MoreIn this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in high distance
... Show MoreDC planar sputtering system is characterized by varying discharge potential of (250-2000 volt) and Argon gas pressures of (3.5×10-2 – 1.5) mbar. The breakdown voltage for silver electrode was studied with a uniform electric field at different discharge distances, as well as plasma parameters. The breakdown voltage is a product of the Argon gas pressure inside the chamber and gab distance between the electrodes, represent as Paschen curve. The Current-voltage characteristics curves indicate that the electrical discharge plasma is working in the abnormal glow region. Plasma parameters were found from the current-voltage characteristics of a single probe positioned at the inter-cathode space. Typical values of the electron temperature an
... Show MorePregnancy- including hypertension(PIH), also known as preeclampsia, is one of the major causes of maternal and fetal death. This study was carried out on 30 pregnant women with preeclampsia and 30 healthy pregnant women as control ranging in age mean ±SD (28.84±3.55) years , BMI (76.80±9.78) Kg/m2 and gestation age(30.82±0.75)week. The aim of this research was studied the plasma Metanephrine level and other biochemical parameters such as Hemoglobin(Hb), serum Protein, S. Albumin, Globulin, Albumin/Globulin ratio (Alb/Glu. ratio), S.Glutamate Pyruvate aminotransferase (GPT), S.Glutamate Oxaloacetate aminotransferase(GOT). The obtained results have been compared with 30 healthy pregnant women as control group. The result showed that ther
... Show MoreObjective: This research was carried out in rats in a special place of the laboratory of histopathological diseases in the period 6/9/2018 until 23/11/2018, this study to detect effect of the addition of the alcohol extract of ginger in the reduction of fat in liver tissue of rats. Method: Eight groups and replicates for each group. The groups were homogenous in weights and were placed in 13 cages. Each group consisted of 10 rat and at 5 fares each. In the first treatment, rat were fed on regular feeding without adding and feeding rats in the second treatment sessions add to it the alcoholic extract of ginger in Turkey 150 mg/kg. The third group is the same as the normal food after adding the alcohol extract of ginger at a concentration of
... Show MoreAnalyze the relationship between genetic variations in the MTHFR gene at SNPs (rs1801131 and rs1801133) and the therapy outcomes for Iraqi patients with rheumatoid arthritis (RA). The study was conducted on a cohort of 95 RA Iraqi patients. Based on their treatment response, the cohort was divided into two groups: the responder (47 patients) and the nonresponder (48 patients), identified after at least three months of methotrexate (MTX) treatment. A polymerase chain reaction-restriction fragment length polymorphism (PCR–RFLP) technique was employed to analyze the MTHFR variations, specifically at rs1801133 and rs1801131. Overall, rs1801131 followed both codominant and dominate models, in which in