Background: The long term survival of dental implants is evaluated by the amount of crestal bone loss around the implants. Some initial loss of bone around dental implants is generally expected. There is reason to believe that reflecting a mucoperiosteal flap promotes crestal bone loss in the initial phase after an implant has been inserted. The surgical placement of a dental implant fixture is constantly changing and in recent years, there has been some interest in developing techniques that minimize the invasive nature of the procedure, with flapless implant surgery being advocated. The purpose of this study was to compare the radiographic level of the peri- implant bone after implant placement between traditional flapped surgery and flapless approach depending on CBCT during 24 weeks healing period. Materials and Methods: A total of 25 Iraqi patients with an age ranged of 20-60 years who received 46 implants. Were randomized into two groups: control group which involved 27 implants inserted by conventional flapped surgical approach and study group which involved 19 implants inserted by flapless surgical approach. The bone level was measured by CBCT for each implant at buccal and palata/lingual sides at two times, immediately after implant placement (base line data), and after 24 weeks healing period. Results: There was no significant difference between study (flapless) and control (flapped) groups in the mean of total crestal bone resorption for buccal and palatal side after 24 weeks from implant placement (P= 0.393 for buccal side and P= 0.214 for palatal side). There was highly significant difference between buccal and palatal side regarding crestal bone loss around implants (P = 0.001) Conclusions: Bone resoption around dental implants placed with conventional flap surgery compared to flapless surgery does not seem to be influenced during the healing period before implant loading.
Cantilever beams are used in many crucial applications in machinery and construction. For example, the airplane wing, the microscopic probe for atomic force measurement, the tower crane overhang and twin overhang folding bridge are typical examples of cantilever beams. The current research aims to develop an analytical solution for the free vibration problem of cantilever beams. The dynamic response of AISI 304 beam represented by the natural frequencies was determined under different working surrounding temperatures ((-100 ℃ to 400 ℃)). A Matlab code was developed to achieve the analytical solution results, considering the effect of some beam geometrical dimensions. The developed analytical solution has been verified successful
... Show MoreComputational study of three-dimensional laminar and turbulent flows around electronic chip (heat source) located on a printed circuit board are presented. Computational field involves the solution of elliptic partial differential equations for conservation of mass, momentum, energy, turbulent energy, and its dissipation rate in finite volume form. The k-ε turbulent model was used with the wall function concept near the walls to treat of turbulence effects. The SIMPLE algorithm was selected in this work. The chip is cooled by an external flow of air. The goals of this investigation are to investigate the heat transfer phenomena of electronic chip located in enclosure and how we arrive to optimum level for cooling of this chip. These par
... Show MoreBackground: C-reactive protein (CRP) is an acute phase protein that its plasma levels increase after trauma or surgery so it is used as an indicator for the level of inflammation after surgery. The objective of this study is to investigate pre- and post-operative levels of CRP in three types of oral surgical interventions (Apicoectomy, Impaction, and Impacted teeth exposure). Materials and Methods: A total number of (48) healthy individuals aged (20-60) years who needed oral surgical intervention for either (removal of impacted third molars, exposure of an impacted canine, or Apicoectomy). A 4ml venous blood was obtained from each patient at two occasions (pre-operatively at the day of operation and post-operatively after 48 hours), then ce
... Show MoreBackground: Bone cutter is widely used in the
Middle east area to cut the prepuce during circumcision.
Results :One hundred twenty one male neonates
were included in this study.The mean operative
time (MOT) was 6 minutes, mean time of
healing (MTH) was 5 days, 7 cases (5.9%)
developed early & late complications, 2 (1.7%)
had bleeding, 3 (2.5%) developed infection, 2
(1.7%) developed late complications in the form
of meatal stenosis.
Settings:Al-Yarmouk Teaching Hospital and a
private surgical clinic.
Aim of the study: To assess the safety of
circumcision using bone cutter.
Methods: Over 6 years period from Jan. 2000
till Dec. 2005, one hundred twenty one male
neonates were circumci
Objective: The study deafs with nursing performance in the surgical wards in general hospital at
Baghdad city.
Methodology : A descriptive evaluation design using, observational method was carried out. Non
probability (purposive) sample of (151) nurses was selected for the study and comprised all nurses who
worked in general surgical wards in the four health sectors( Rusaffa , Al-Karkh, Al-Yarmok, Medical
city health sector) at time of collecting the data. A check list questionnaire was constructed by the
researcher for the purpose of the study; it is composed of (2) major parts, part (I) is concerned with
socio-demographic data and the second part is composed of two minor parts thev concerned with
availability of
A roundabout is a highway engineering concept meant to calm traffic, increase safety, reduce stop-and-go travel, reduce accidents and congestion, and decrease traffic delays. It is circular and facilitates one-way traffic flow around a central point. The first part of this study evaluated the principles and methods used to compare the capacity methods of roundabouts with different traffic conditions and geometric configurations. These methods include gap acceptance, empirical, and simulation software methods. Previous studies mentioned in this research used various methods and other new models developed by several researchers. However, this paper's main aim is to compare different roundabout capacity models for acceptabl
... Show MoreThe electrical properties of the AlNiCo thin films with thickness (1000oA) deposited on glass substrates using Ion – Beam sputtering (IBS) technique under vacuum <10-6 torr have been studied . Also it studied the effect of annealing temperature from this films , It is found that the effective energy decrease with increase of temperature and the conductivity decrease with increase temperature 323oK but after this degree the conductivity increasing .
This text and guide discusses the surgical and medical management of congenital heart diseases in both adult and children. It describes the disease, pathology, treatment, complications and follow-up with extensive use of didactic material to educate the reader to the practicalities of the subject. It details the novel research via an extensive literature review, while covering all aspects of the surgical and medical treatment of congenital heart disease. It includes review of the laparoscopic techniques and epidemiology of each disease involved and their prevalence to provide the reader with the full clinical picture. Clinical and Surgical Aspects of Congenital Heart Diseases: Text and Study Guide provides a thorough practical reference fo
... Show More