Background: The purpose of this study is to investigate the relationship between the roots of the maxillary posterior teeth and the maxillary sinus using spiral computed tomography, and measured the distances between the roots of the maxillary posterior teeth and the sinus floor. Materials and Methods: The sample of the present study was a total of 120 Iraqi subject (60 males & 60 females) aged (20-60) years old, who admitted to spiral Computed Tomography scan unit in AL-Zahraa hospital in AL-Kut city to have Computed Tomography scan of the brain and paranasal sinuses who had complaints of headaches or with suspicion of sinusitis but without pathological findings in maxillary sinuses. From November 2012 to April 2013, CT sagittal reconstructed images were used in this study, Images were classified according to the relation between the root apices and the maxillary sinus floor into type1: Root apices below the sinus floor, type 2: Root apices in cosines floor. Vertical distance were measured between the deepest point of the maxillary sinus floor and the root apices of the maxillary first and second premolars and first, second molar contact with the sinus floor) and type 3: Root apices penetrate or inside the r using built-in measurement tools. Means, standard deviations and minimum and maximum values were calculated for all right and left premolars and molars. t-tests were used to compare measurements between left and right sides and between female and male patients. Results: The distance between sinus floor and root apex was longest for the first premolar palatal root apex and shortest for the second molar mesoibuccal root apex for both right and left sides. No statistically significant differences were found between the right and left side measurements or between females and males patients. Conclusion: There was no significant difference in vertical relation of maxillary posterior teeth to floor of maxillary sinus between male and female and between right and left side. The mesiobuccal root of the maxillary 2nd molar was closest to the maxillary sinus floor and palatal root of 1st premolar was farthest to the sinus floor.
In this study, a three-dimensional finite element analysis using ANSYS 12.1 program had been employed to simulate simply supported reinforced concrete (RC) T-beams with multiple web circular openings subjected to an impact loading. Three design parameters were considered, including size, location and number of the web openings. Twelve models of simply supported RC T-beams were subjected to one point of transient (impact) loading at mid span. Beams were simulated and analysis results were obtained in terms of mid span deflection-time histories and compared with the results of the solid reference one. The maximum mid span deflection is an important index for evaluating damage levels of the RC beams subjected to impact loading. Three experi
... Show MoreThis study investigates the effectiveness of mental games in enhancing shooting accuracy among young basketball players. Initially, baseline shooting accuracy was assessed through tests conducted prior to a three-week intervention involving mental games. A follow-up test revealed a significant improvement in participants' shooting accuracy following the intervention. Given the noticeable differences in the new shooting scores compared to the initial assessments, a second set of pre-intervention tests was conducted. These tests reaffirmed the significant enhancement in shooting accuracy, substantiating the hypothesis that mental games positively affect performance. The findings highlight the importance of these intervention programs
... Show MoreThis study investigates the effectiveness of mental games in enhancing shooting accuracy among young basketball players. Initially, baseline shooting accuracy was assessed through tests conducted prior to a three-week intervention involving mental games. A follow-up test revealed a significant improvement in participants' shooting accuracy following the intervention. Given the noticeable differences in the new shooting scores compared to the initial assessments, a second set of pre-intervention tests was conducted. These tests reaffirmed the significant enhancement in shooting accuracy, substantiating the hypothesis that mental games positively affect performance. The findings highlight the importance of these intervention programs
... Show MoreAccurate calculation of transient overvoltages and dielectric stresses from fast-front excitations is required to obtain an optimal dielectric design of power components subjected to these conditions, which are commonly due to switching and lightning, as well as utilization of power-electronic devices. Toroidal transformers are generally used at the low voltage level. However, recent investigations and developments have explored their use at the medium voltage level. This paper analyzes the model-based improvement of the insulation design of medium voltage toroidal transformers. Lumped and distributed parameter models are used and compared to predict the transient response and dielectric stress along the transformer winding. The parameters
... Show MoreThe cost‐effective dual functions zeolite‐carbon composite (DFZCC) was prepared using an eco‐friendly substrate prepared from bio‐waste and an organic adhesive at intermediate conditions. The green synthesis method used in this study ensures that chemically harmless compounds are used to obtain a homogeneous distribution of zeolite over porous carbon. The greenly prepared dual‐function composite was extensively characterized using Fourier transform infrared, X‐ray diffraction, thermogravimetric analysis, N2 adsorption/desorption isotherms, field emission scanning electron microscope, dispersive analysis by X‐ray, and point of zero charges. DFZCC had a surface area o